UL Recognized Component. Note: Metric dimensions are displayed in [mm]. - 2 -. Unit Dimensions. UL Recognized Component. Mounting Feet Dimensions. A. B. C. (in) (mm) (in) (mm) (in) (mm) .562. 14. 1.156. 29. 1.844. 47. Optional Mounting Feet. 1.250. [32] .500. [13] .125. [3] .625. [16]. B. C. ØA. R.125 .563 X .750. SLOT.
Type SCG Current Transformer 600 Volt, 10 kV BIL, Indoor Product Bulletin 1VAP428651-DB
Application The SCG current transformer is used as the source of current for relaying and metering. It is available in five internal window diameter sizes and dual and multi-ratio designs are available upon request.
Product Features • 600 Volt Indoor • 10 kV BIL
• Primary Amperes 50-4000
Construction Features The ring-type core is insulated and toroidally wound with a fully distributed secondary winding. The protective case, made of an impactresistant polycarbonate, is ultrasonically sealed.
• Mechanical Rating: 180 x rated current
Secondary Terminals Secondary terminals are 10-32 brass terminal studs with hardware.
• Thermal Rating: Refer to tables on pages 3 and 4
Curves Saturation, overcurrent, ratio correction factor, and phase-angle curves are available upon request.
• 25 through 400 Hertz
• Continuous Current Rating Factor: Refer to tables on pages 3 and 4
Test Reports IEEE test reports are stored electronically and can be e-mailed in various formats at the time of shipment.
• UL Recognized Component; File No. E96461
Standards This unit meets all applicable IEEE and NEMA standards and is a UL Recognized Component. UL Recognized Component
Unit Dimensions
Optional Mounting Feet
.75 [19] Ø.56 HOLE 4-TOTAL
1.63 [41]
#10-32 TERM STUD 2-TOTAL X2
.500 [13]
X1
.563 X .750 SLOT
5
7.56 [192]
1.250 [32]
3 4 1 2
5.75 [146]
H1
.625 [16]
ØA
.125 [3]
7.13 [181]
3.51 [89]
C
R.125
B
R
4.00 [102]
5.75 [146] 3.50 [89] 7.00 [178]
Type SCG-1 SCG-2 SCG-3 SCG-4 SCG-5
Window Size (in) (mm)
Thickness (in) (mm)
2.25 2.75 3.25 4.00 4.625
4.0 4.0 4.0 4.0 4.0
57 70 83 102 117
102 102 102 102 102
Weight (lbs)
Mounting Feet Dimensions A (in) (mm)
27 23 21 19 14
.562
14
(in) 1.156
B (mm) 29
(in) 1.844
C (mm) 47
Note: Metric dimensions are displayed in [mm].
-2-
Selection Guide Primary Ampere Rating
Continuous Current Rating 30° C 55° C
IEEE Metering Accuracy B-0.1
B-0.2
B-0.5
B-0.9
B-1.8
IEEE Relaying Accuracy
Thermal Rating*
Style Number
Type SCG-1 (2.25" window) 50
2.0
1.5
2.4
2.4
4.8
-
-
C10
100
7525A26G01
75
2.0
1.5
1.2
1.2
2.4
-
-
C20
100
7525A26G02 7525A26G03
100
2.0
1.5
0.6
1.2
2.4
2.4
4.8
C20
100
150
2.0
1.5
0.3
0.6
1.2
1.2
2.4
C50
100
7525A26G04
200
2.0
1.5
0.3
0.3
0.6
0.6
1.2
C50
100
7525A26G05
250
2.0
1.5
0.3
0.3
0.3
0.6
1.2
C50
100
7525A26G06 7525A26G07
300
2.0
1.5
0.3
0.3
0.3
0.3
0.6
C100
100
400
2.0
1.5
0.3
0.3
0.3
0.3
0.3
C100
100
7525A26G08
500
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C100
80
7525A26G09
600
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C200
80
7525A26G10
50
2.0
1.5
2.4
4.8
-
-
-
C10
100
7525A27G01
75
2.0
1.5
1.2
1.2
4.8
4.8
-
C10
100
7525A27G02 7525A27G03
Type SCG-2 (2.75" window)
100
2.0
1.5
0.6
1.2
2.4
2.4
4.8
C20
100
150
2.0
1.5
0.3
0.6
1.2
1.2
2.4
C20
100
7525A27G04
200
2.0
1.5
0.3
0.3
0.6
1.2
1.2
C50
100
7525A27G05
250
2.0
1.5
0.3
0.3
0.6
0.6
1.2
C50
100
7525A27G06 7525A27G07
300
2.0
1.5
0.3
0.3
0.3
0.6
0.6
C50
100
400
1.5
1.0
0.3
0.3
0.3
0.3
0.6
C100
80
7525A27G08
500
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C100
80
7525A27G09
600
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C100
80
7525A27G10 7525A27G12
800
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
1000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A27G13
1200
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A27G14
1500
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A27G15
50
2.0
1.5
2.4
2.4
C10
100
7525A28G01
Type SCG-3 (3.25" window) -
-
-
75
2.0
1.5
1.2
2.4
4.8
-
-
C10
100
7525A28G02
100
2.0
1.5
1.2
1.2
2.4
4.8
4.8
C20
100
7525A28G03
150
2.0
1.5
0.6
0.6
1.2
2.4
2.4
C20
100
7525A28G04
200
2.0
1.5
0.3
0.6
0.6
1.2
2.4
C50
100
7525A28G05
250
2.0
1.5
0.3
0.6
1.2
1.2
2.4
C50
100
7525A28G06
300
2.0
1.5
0.3
0.3
0.3
0.6
1.2
C50
100
7525A28G07
400
2.0
1.5
0.3
0.3
0.3
0.3
0.6
C100
100
7525A28G08
500
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C100
80
7525A28G09
600
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C100
80
7525A28G10 7525A28G12
800
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C200
80
1000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A28G13
1200
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A28G14
1500
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A28G15
* times normal, 1 second
Optional Accessories • Mounting Feet
(Selection Guide continued on page 4)
9628A05G81 -3-
Selection Guide (continued from page 3) Primary Ampere Rating
Continuous Current Rating 30° C 55° C
IEEE Metering Accuracy B-0.1
B-0.2
B-0.5
B-0.9
B-1.8
IEEE Relaying Accuracy
Thermal Rating*
Style Number 7525A29G01
Type SCG-4 (4.0" window) 50
2.0
1.5
2.4
4.8
-
-
-
C5
100
75
2.0
1.5
2.4
2.4
4.8
-
-
C10
100
7525A29G02
100
2.0
1.5
1.2
1.2
2.4
4.8
-
C10
100
7525A29G03
150
2.0
1.5
0.6
0.6
1.2
2.4
4.8
C20
100
7525A29G04
200
2.0
1.5
0.3
0.6
1.2
1.2
2.4
C20
100
7525A29G05
250
2.0
1.5
0.3
0.3
0.6
1.2
1.2
C20
100
7525A29G06 7525A29G07
300
2.0
1.5
0.3
0.3
0.6
0.6
1.2
C50
100
400
2.0
1.5
0.3
0.3
0.3
0.3
0.6
C50
100
7525A29G08
500
1.5
1.0
0.3
0.3
0.3
0.3
0.6
C50
80
7525A29G09
600
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C100
80
7525A29G10
800
1.5
1.0
0.3
0.3
0.3
0.3
0.3
C100
80
7525A29G12
1000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C100
60
7525A29G13
1200
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C100
60
7525A29G14
1500
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C100
60
7525A29G15
2000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A29G17
2500
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A29G18
3000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A29G19
4000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C200
60
7525A29G20
7525A30G01
50
-
-
2.4
4.8
-
-
-
-
-
75
2.0
1.5
2.4
2.4
4.8
-
-
C5
-
7525A30G02
100
2.0
1.5
1.2
2.4
4.8
-
-
C10
100
7525A30G03
150
2.0
1.5
1.2
1.2
2.4
4.8
-
C10
100
7525A30G04
200
2.0
1.5
0.6
0.6
1.2
2.4
4.8
C20
100
7525A30G05
250
2.0
1.5
0.3
0.6
1.2
1.2
2.4
C20
100
7525A30G06
300
2.0
1.5
0.3
0.3
0.6
1.2
2.4
C20
100
7525A30G07
400
2.0
1.5
0.3
0.3
0.3
0.6
1.2
C50
100
7525A30G08
500
2.0
1.5
0.3
0.3
0.3
0.6
0.6
C50
100
7525A30G09
600
1.5
1.0
0.3
0.3
0.3
0.3
0.6
C50
80
7525A30G10
800
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C50
60
7525A30G12
1000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C100
60
7525A30G13
1200
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C100
60
7525A30G14
1500
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C100
60
7525A30G15
2000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C100
60
7525A30G17
2500
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C20
60
7525A30G18
3000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C20
60
7525A30G19
4000
1.33
1.0
0.3
0.3
0.3
0.3
0.3
C20
60
7525A30G20
Additional styles available upon request. Contact your ABB Sales Representative or call +1-252-827-3212 for more information. * times normal, 1 second
ABB Inc. 3022 NC 43 North Pinetops, NC 27864 Tel: +1-252-827-3212 www.abb.com/mediumvoltage
bolt holes facilitate mounting. Secondary Terminals. Secondary terminals are 10-32 stud-type with hardware. Curves. Saturation, overcurrent, ratio correction factor, and phase-angle curves are available upon request. Test Reports. IEEE test reports a
Application. The CO-9740 indoor, split-core window-type current transformer is a 600 volt, 10 kV BIL rated unit. Primary current ratios are available from 100:5 to 4000:5 at 60 Hertz with a rating factor of up to. 1.5. This unit is convenient to inst
Application. The RLC is designed for high burden metering and relaying applications and is available in single or dual ratios. It may be used with uninsulated bus bar or cable up to 600 volts or with insulated primary conductors at higher voltages. C
48 x 36 x 11. 16.25. 800. 600. 30 4W. 3. CTMB8003L or. (6) 1/0-250. 36 x 30 x 11. 10.25. (6) 1/0 250. KCMIL. 36 x 36 x 11. 10.25. (1) 1/0-600. 48 x 30 x 11. 16.25.
18. For vertical mounting. Bushings max. 3000 kg (6600 lb). If a lifting device for application at ...... tap, and the capacitance C2, between the test tap and earth.
and the electrical connection is made through a spiral spring fastened to the moving contact arm and frame assembly. 2.2 Indicating contactor switch (Ics).
the heating element, buy a suitable descaler and descale your kettle. After descaling ... deposit on the side of the kettle. This is normal but can be removed with.
the controlled trimming of moustache or sideburns. Keeping your shaver in top shape. About every four weeks, clean the cutter block with Braun cleaning agents.
e blocco coltelli), premere con una penna a sfera sul tasto reset (9) per almeno 3 secondi per risettare il software. Mentre avrete il tasto premuto la spia lampeg- gerà e si spegnerà una volta che il software sarà resettato. L'operazione di reset pu
fitted as the Kitchen Machine could become unstable. ⢠Do not operate your appliance near the edge of a work surface. ⢠This appliance shall not be used by ...