TECHNICAL BROCHURE BSSH R1
SSH S & M-GROUP 316 STAINLESS STEEL END SUCTION PUMPS BOMBAS DE SUCCIÓN FINAL DE 316 ACERO INOXIDABLE GRUPO-M Y S
Goulds Water Technology Commercial Water A FULL RANGE OF PRODUCT FEATURES, UNA GAMA TOTAL DE CARACTERÍSTICAS DEL PRODUCTO Superior Materials of Construction: AISI Type 316L stainless steel pump parts for reduced corrosion and improved strength and ductility. Frame Mounted Design: Flexibility of installation and driver arrangements. Back Pull-Out Design: Simplifies maintenance when used with spacer type coupling. Cast Iron Power Frame: Rigidly supported, grease lubricated ball bearing assembly.
PAGE 2
Mechanical Seal: Standard John Crane Type 21 mechanical seal. Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase. Suction and Discharge Flanges: Mate with ANSI class 150 flanges. Close-Coupled Design: Compact design saves space and simplifies maintenance.
Materiales Superiores de Construcción: Partes de la bomba de acero inoxidable AISI Tipo 316L para corrosión reducida y fuerza y ductilidad mejoradas. Diseño de Armazón Montado: Flexibilidad de instalación y colocación del motor. Diseño de Extracción Trasera: Simplifica el mantenimiento cuando se usa con el acople tipo espaciador. Armazón del Motor de Hierro Fundido: Rígidamente soportado, con ensamblaje de balineras de bolas lubricadas con grasa .
Sello Mecánico: Sello mecánico estándar John Crane Tipo 21. Motores de Accionamiento: Motores de armazón-T NEMA estándar unifásicos o trifásicos. Bridas de Succión y Descarga: Acoplan con bridas ANSI clase 150. Diseño de Acople Cerrado: El diseño compacto ahorra espacio y simplifica el mantenimiento.
Goulds Water Technology Commercial Water PERFORMANCE COVERAGE, 3500 AND 1750 RPM ALCANCE DE FUNCIONAMIENTO, 3500 Y 1750 RPM METERS (METROS)
FEET (PIES) 600
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL)
175
150
125
3500 RPM 500
400
100
27SH
24SH
300
28SH
11SH 25SH
75
23SH
200
10SH
50
25
0
22SH
7SH 100
8SH
9SH
6SH 5SH
4SH 0 0 0
100
200
20
40
300
400 80
60
600
500
100
120
140
700 160
900
800 180
200
1000 220
1100 240
1200
260 m3/hr
CAPACITY (CAPACIDAD) – U.S. GPM METERS (METROS)
FEET (PIES)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL)
150
1750 RPM
40 125
30
100
75 20
24SH 11SH
50
10 25
0 0 0
28SH
10SH
9SH
7SH
8SH
22SH
100 20
200 40
23SH
6SH
5SH
4SH 0
27SH
25SH
300 60
400 80
100
500 120
CAPACITY (CAPACIDAD) – U.S. GPM
600 140
700
800
160 m3/hr 180 PAGE 3
Goulds Water Technology Commercial Water SSH S/M-GROUP NUMBERING SYSTEM SISTEMA DE NUMERACIÓN DEL GRUPO-S/M SSH Example Product Code, Ejemplo Código del Producto 24 SH 1 Q 1 2 A 0 R Casing Rotation, Optional R = 3 o’clock B = 6 o’clock
L = 9 o’clock
Rotación de la cubierta, opcional R = 3 hora B = 6 hora L = 9 hora
NOTE: Rotation when viewed from suction end of pump. Standard discharge position is 12 o’clock.
NOTA: Rotación cuando está visto del extremo de la succión de la bomba. La posición estándar de la descarga es las 12.
Mechanical Seals and O-Ring 0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below.
Sello Mecánico y Anillo ‘0’ 0 = Estándar aprobado. Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo.
John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Seal Code, Código del Sello 0 2 5
Rotary, Rotativo
Stationary, Estacionario
Carbon
Sil-Carb
Sil-Carb
Sil-Carb
Elastomers, Elastómeros
Metal Parts, Partes Metálicas
Viton
316 SS, 316 Acero inoxidable
EPR Viton
Impeller Option Code - For optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve. NOTE: For trimmed impellers, use T for impeller code.
Part No., Pieza Número 180-210 Frames, Armazones
250-360 Frames, Armazones
10K27
10K45
10K19
10K20
10K64
10K65
Código del Impulsor Opcional - Para diámetros del impulsor opcional modificar el número de orden del catálogo con el código del impulsor anotado abajo. Seleccionar el diámetro del impulsor opcional de la curva de funcionamiento de la bomba. NOTA: Para los impulsores cortados, utilice T para el código del impulsor.
Pump Size, Tamaño de la Bomba 9SH 10SH 11SH 4SH 7SH 5SH 8SH *6SH *22SH *23SH 24SH 25SH *27SH *28SH 1 x 2-6 1 x 2-8 1 x 2-10 1½ x 2½-6 1½ x 2½-8 2 x 2½-6 2 x 2½-8 2½ x 3-6 2½ x 3 – 8 3 x 4 – 8 1½ x 2½ – 2 x 2½ 2½ x 3 3 x 4 – 10 Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. 10 Dia. – 10 Dia. – 10 Dia. Dia. 827⁄64 103⁄32 6¾ 8¼ 67⁄8 8¼ 75⁄16 91⁄16 91⁄16 97⁄8 97⁄8 103⁄8 105⁄8 A 65⁄8 B 67⁄16 81⁄16 917⁄32 63⁄8 713⁄16 67⁄16 7¾ 71⁄8 8¾ 811⁄16 9½ 9½ 915⁄16 10¼ 711⁄16 91⁄8 61⁄16 7 513⁄16 7½ 615⁄16 8½ 87⁄16 93⁄16 91⁄8 99⁄16 913⁄16 C 511⁄16 D 53⁄8 73⁄8 8¾ 55⁄8 6¾ 5½ 73⁄16 611⁄16 8¼ 81⁄16 87⁄8 813⁄16 9¼ 97⁄16 E 71⁄8 55⁄16 67⁄16 51⁄8 67⁄8 63⁄8 77⁄8 711⁄16 89⁄16 83⁄16 8¾ 91⁄16 F 411⁄16 61⁄8 413⁄16 63⁄16 61⁄16 7½ 7½ 8¼ 715⁄16 811⁄16 G 43⁄8 47⁄16 55⁄8 71⁄8 71⁄8 711⁄16 H 43⁄16 611⁄16 67⁄8 J 6½ 6½ K 6 L 5½ NOTE: Impellers will be trimmed in 1/16” increments only. If NOTA: Los impulsores serán cortados en 1/16 " incrementos you are ordering a trim within 1/16” of the standard impeller, solamente. Si usted está pidiendo un ajuste dentro de 1/16 " del you will receive the standard impeller trim. impulsor estándar, usted recibirá el ajuste estándar del impulsor. * Indicates impellers that can be trimmed * Indica los impulsores que pueden ser cortados Impeller Code, Código del impulsor
Motor Enclosure, Caja del motor 1 = ODP 2 = TEFC 3 = Explosion Proof, Prueba de explosiones 4 = ODP Premium Eff., Eficiencia superior
5 = TEFC Premium Eff., Eficiencia superior 6 = XP Premium Eff., Eficiencia superior 7 = Wash down, Lavado
Motor Voltage, Voltaje del motor 1 = 115/208-230 3 = 230 2 = 115/230 4 = 230/460
5 = 208-230/460 6 = 460
HP Rating, Potencia nominal, HP C = ½ F = 1.5 J = 5 D = .75 G = 2 K = 7.5 E = 1 H = 3 L = 10
M = 15 N = 20 P = 25
7 = 575 X = Non Std.
Q = 30 R = 40 S = 50
T = 60 U = 75 V = 100
Frame Options, Opciones de mando Substitute, Description, Substituto Descripción 7/8" Imp. Bore, Diámetro FRM2 interior del impulsor 7/ " 8 1¼" Imp. Bore, Diámetro FRM3 interior del impulsor 1¼"
Driver: Hertz/Pole/RPM, Fuerza motriz: Hertz/Polos/RPM 1 = 60/3500/1 3 = 60/1750/1 5 = 50/2900/1 2 = 60/3500/3 4 = 60/1750/3 6 = 50/2900/3 Material SH = 316L Stainless steel, Acero inoxidable
PAGE 4
Pump Size, Tamaño de la Bomba 9 = 1 x 2 – 6 4 = 1½ x 2½ – 6 10 = 1 x 2 – 8 7 = 1½ x 2½ – 8 11 = 1 x 2 – 10 5 = 2 x 2½ – 6 23 = 3 x 4 – 8 24 = 1½ x 2½ – 10 27 = 2½ x 3 – 10 28 = 3 x 4 – 10
8 = 2 x 2½ – 8 6 = 2½ x 3 – 6 22 = 2½ x 3 – 8 25 = 2 x 2½ – 10
NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with GWT on non-cataloged numbers. NOTA: No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con GWT en los números no catalogados.
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM METERS FEET METROS PIES 200 60
Model SSH / 9SH Size (Tamaño) 1 x 2 - 6 RPM 3500 Curve (Curva) CN0619R00
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
5' NPSHR – FEET (PIES) 39
A 65/8" DIA.
50
B 67/16" 150
40
A 65⁄8" 5 B 67⁄16 5 C 511⁄16 3 D 53⁄8 3
8'
49
10'
54
56 EFF%
C 511/16"
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
D 53/8" 30
100
20
5 HP 3 HP
50 10 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0
25
0
50
5
75
10
100
15
125
20
25
U.S. GPM 150 30
m3/hr
CAPACITY (CAPACIDAD) (Q)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
METERS FEET METROS PIES 300 90
80 250 70
60
Model SSH / 10SH Size (Tamaño) 1 x 2 - 8 RPM 3500 Curve (Curva) CN0613R00
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 827/64" DIA.
A 827⁄64" 10 B 81⁄16 10 C 711⁄16 7½ D 73⁄8 7½ E 71⁄8" 7½
6' NPSHR – FEET (PIES)
33
42
B 81/16"
10'
14'
C 711/16" 200
18'
47
22'
D 73/8"
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
49 42 EFF%
E 71/8"
50 150 40
30
100
20 50 0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
25 5
50 10
75 15
100 20
71/2 HP
125 25
150 30
35
10 HP 175 U.S. GPM 200 40
m3/hr
CAPACITY (CAPACIDAD) (Q)
PAGE 5
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM METERS FEET METROS PIES 450
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
130 120
NPSHR – FEET (PIES)
3 400 A 10 /32" DIA.
22’
17 350 B 9 /32"
90 80
25'
43 27'
100 300
250
A 103⁄32" 20 B 917⁄32 15 C 91⁄8 15 D 8¾ 15
30 38
110
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 11SH Size (Tamaño) 1 x 2 - 10 RPM 3500 Curve (Curva) CN0616R00
C 91/8"
45
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
29' 43 EFF%
D 83/4"
70 60 50
200
10 HP 150
20 HP
40 30
100
20 50 0
15 HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
25
0
50 10
5
75
100
15
20
125
150 30
25
175 U.S. GPM 200
35
40
m3/hr
CAPACITY (CAPACIDAD) (Q)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
60
5’ NPSHR – FEET (PIES) 175
50
55
A 6 /4" DIA. 3
8'
59 61 63
B 6 /8" 3
150 40
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 4SH Size (Tamaño) 11/2 x 21/2 - 6 RPM 3500 Curve (Curva) CN0488R01
METERS FEET METROS PIES
65
C 61/16" 65 12'
125 D 55/8"
63 61 EFF%
E 55/16" 30
100 10 HP
F 411/16" 75 G 43/8"
71/2 HP
20 H 43/16" 50
5 HP 3 HP
10 25
0
0
2 HP NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
50 10
150
100 20
30
40
CAPACITY (CAPACIDAD) (Q)
PAGE 6
250 U.S. GPM
200 50
m3/hr
A 6¾" 10 B 63⁄8 7½ C 61⁄16 7½ D 55⁄8 5 E 55⁄16 5 F 411⁄16 3 G 43⁄8 3 H 43⁄16 2 NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
METERS FEET METROS PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
1 275 A 8 /4" DIA.
6’ NPSHR – FEET (PIES)
40
80
60
50
30
20
55
56 57
225
8' 58 59 10'
200 C 7" D 63/4" 175 E 67/16"
14' 59
F 6 /8" 1
150 40
A 8¼" 15 B 713⁄16 15 C 7 10 D 6¾ 10 E 67⁄16 7½ F 61⁄8 7½
50 250 B 713/16"
70
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 7SH Size (Tamaño) 11/2 x 21/2 - 8 RPM 3500 Curve (Curva) CN0491R00
58
NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
57 EFF%
15 HP
125 100
10 HP 71/2 HP
75 50
10
0
25 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
25
0
50
0
100
75
10
125
20
150
175
30
225
200
40
250
50
275 U.S. GPM m3/hr
60
CAPACITY (CAPACIDAD) (Q)
60 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 5SH Size (Tamaño) 2 x 21/2 - 6 RPM 3500 Curve (Curva) CN0494R01
METERS FEET METROS PIES
50 6’ NPSHR – FEET (PIES)
A 67/8" DIA.
60
175
64
B 67/16"
50
10' 66 67
150 40
14'
68 C 5 /16" 13
125
68 19' 67
D 51/2"
66 EFF%
E 5 /8" 1
30
100
F 413/16" 15 HP
G 47/16"
75
A 67⁄8" 15 B 67⁄16 15 C 513⁄16 10 D 5½ 10 E 51⁄8 7½ F 413⁄16 7½ G 47⁄16 5 NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
20 10 HP
50 71/2 HP
10
5 HP
25
0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
50
100 20
150
200 40
250
300
60
350 80
400
U.S. GPM 100 m3/hr
CAPACITY (CAPACIDAD) (Q)
PAGE 7
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM METERS FEET METROS PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
90
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 8SH Size (Tamaño) 2 x 21/2 - 8 RPM 3500 Curve (Curva) CN0497R01 8’ NPSHR – FEET (PIES)
300 50
A 81/4" DIA.
60
A 8¼" B 7¾ C 7½ D 73⁄16 E 67⁄8 F 63⁄16
10'
65 69
80 250 70
71
B 73/4"
13'
C 71/2"
16'
D 7 /16" 3
60
200
50 150
71
E 67/8"
21' 69 65 EFF%
F 63/16"
40
25 20 20 15 15 10
NOTE: Pump will pass a sphere to ¼" diameter. NOTA: La bomba pasará una esfera a ¼" diámetro.
25 HP
30
10 HP
100
15 HP
20 HP
20 50 10 0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
50
100
0
200
150
20
250
40
300
350
60
400
U.S. GPM 100 m3/hr
80
CAPACITY (CAPACIDAD) (Q)
METERS FEET METROS PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
80
7’ NPSHR – FEET (PIES)
250 A 75/16" DIA. 200
65
B 71/8" C 615/16"
8' 70 70
10' 68
D 611/16"
13'
E 6 /8" 3
50
66
150 F 61/16" 40
30
A 75⁄16" 25 B 71⁄8 25 C 615⁄16 20 D 611⁄16 20 E 63⁄8 15 F 61⁄16 15 G 55⁄8 10
60
70
60
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 6SH Size (Tamaño) 21/2 x 3 - 6 RPM 3500 Curve (Curva) CN0500R00
15' 20' 65
G 55/8"
25' 63
100
60 EFF%
20
25 HP
50
20 HP 15 HP
10
10 HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0
0
100
0
25
200 50
400
300 75
500 100
CAPACITY (CAPACIDAD) (Q)
PAGE 8
700
600 125
150
m /hr 3
U.S. GPM 175
NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
FEET PIES 50
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 9SH Size (Tamaño) 1 x 2 - 6 RPM 1750 Curve (Curva) CN0620R00 NPSHR – FEET (PIES) A 65/8" DIA.
50
B 67/16"
4'
A 65⁄8" ¾ B 67⁄16 ¾ C 511⁄16 ½ D 53⁄8 ½
55
40
5'
56
6' 8'
C 511/16"
55 EFF%
3 30 D 5 /8"
20
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
/4 HP
3
/2 HP
1
10
0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
10
20
30
40
50
70 U.S. GPM 80
60
CAPACITY (CAPACIDAD) (Q)
FEET PIES 70 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
A 827/64" DIA. 60
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 10SH Size (Tamaño) 1 x 2 - 8 RPM 1750 Curve (Curva) CN0614R00 4’ NPSHR – FEET (PIES) 5' 42
B 81/16"
6'
C 711/16"
47
8'
50
49 EFF%
D 73/8" 40
A 827⁄64" 1½ B 81⁄16 1½ C 711⁄16 1 D 73⁄8 ¾ E 71⁄8 ¾
E 71/8" 11/2 HP
30
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
1 HP
/4 HP
3
20
10
0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
10
20
30
40
50
60
70 U.S. GPM 80
CAPACITY (CAPACIDAD) (Q) PAGE 9
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM FEET PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
120
Model SSH / 11SH Size (Tamaño) 1 x 2 - 10 RPM 1750 Curve (Curva) CN0617R00
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
NPSHR – FEET (PIES) 36 100 A 10 /32 "
A 103⁄32" 3 B 917⁄32 3 C 91⁄8 2 D 8¾ 2
38
8'
3
14'
12'
43
17'
B 917/32" 80
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
45
C 91/8"
43 EFF%
D 83/4"
60
1.5 HP
40
3 HP
2 HP 20
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
25
50
75
U.S. GPM 100
CAPACITY (CAPACIDAD) (Q)
15
4’ NPSHR – FEET (PIES) 54
A 6 /4" DIA. 3
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 4SH Size (Tamaño) 11/2 x 21/2 - 6 RPM 1750 Curve (Curva) CN0489R01
METERS FEET METROS PIES
6'
59 60 61
40 B 63/8"
62
C 61/16" 62 8'
10 30
D 55/8"
61 60 EFF%
E 55/16"
5
11 20 F 4 /16" G 43/8" H 43/16"
/4 HP
3
0
0 0 0
/ HP
1 2
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
20 5
40
60 10
80 15
100 20
CAPACITY (CAPACIDAD) (Q)
PAGE 10
120 25
1 1 1 ¾ ¾ ½ ½ ½
NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
1 HP
10
A 6¾" B 63⁄8 C 61⁄16 D 55⁄8 E 55⁄16 F 411⁄16 G 43⁄8 H 43⁄16
U.S. GPM 30 m3/hr
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM METERS FEET METROS PIES
6’ NPSHR – FEET (PIES)
A 81/4" DIA. TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia A 8¼" 2 B 713⁄16 2 C 7 1½ D 6¾ 1½ 7 E 6 ⁄ 1 1 6 1 F 6 ⁄ 1 8
Model SSH / 7SH Size (Tamaño) 11/2 x 21/2 - 8 RPM 1750 Curve (Curva) CN0492R00 38
20
48 B 713/16"
60
53
54 55
8' 56 57 10'
C 7"
15
13'
D 63/4"
57
E 67/16" 40
F 61/8"
56
NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
55 EFF%
2 HP
10
11/2 HP
20
1 HP
5
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0
20
0
40
60 10
5
80 15
20
U.S. GPM
120
100 25
m3/hr
30
CAPACITY (CAPACIDAD) (Q)
A 67/8" DIA. TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 5SH Size (Tamaño) 2 x 21/2 - 6 RPM 1750 Curve (Curva) CN0495R00
METERS FEET METROS PIES
48 4’ NPSHR – FEET (PIES) 58
7 40 B 6 /16"
63 7' 65 66 9'
67
C 513/16"
10
1 30 D 5 /2"
67 12' 66
E 51/8"
65 EFF%
F 413/16" 2 HP
20 G 4 /16" 7
5
A 67⁄8" 2 B 67⁄16 2 C 513⁄16 1½ D 5½ 1½ E 51⁄8 1 F 413⁄16 1 G 47⁄16 ¾ NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
11/2 HP 1 HP
10
/4 HP
3
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0 0
40 10
80
160
120 20
30
200 40
U.S. GPM 50
m3/hr
CAPACITY (CAPACIDAD) (Q) PAGE 11
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM METERS FEET METROS PIES
A 81/4" DIA.
20 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 8SH Size (Tamaño) 2 x 21/2 - 8 RPM 1750 Curve (Curva) CN0498R01
60
48
58
B 73/4" C 71/2"
5’ NPSHR – FEET (PIES) 67 63 7' 69
D 73/16" 15
A 8¼" 3 B 7¾ 3 C 7½ 2 D 73⁄16 2 E 67⁄8 1½ F 63⁄16 1½
9'
50 E 6 /8" 7
11' 69 67 EFF%
F 63/16" 40
NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
3 HP
10 30
2 HP
11/2 HP
20 5 10 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0
40
80
10
0
160
120 20
200 40
30
U.S. GPM m3/hr
50
CAPACITY (CAPACIDAD) (Q)
Model SSH / 6SH Size (Tamaño) 21/2 x 3 - 6 RPM 1750 Curve (Curva) CN0502R00
METERS FEET METROS PIES
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
20 4’ NPSHR – FEET (PIES)
60
A 75⁄16" 3 B 71⁄8 3 C 615⁄16 3 D 611⁄16 3 E 63⁄8 2 F 61⁄16 2 G 55⁄8 1½
57 A 75/16" DIA. 15
62
50 B 71/ " 8 C 615/16"
5' 67 67
7' 65
D 611/16"
9'
40 E 63/8"
63
F 61/16"
11'
15'
62
10 30 G 55/8"
NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
19' 60 57 EFF%
20 5 3 HP
10
0
0 0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
100 25
U.S. GPM 400
300
200 50 CAPACITY (CAPACIDAD) (Q)
PAGE 12
2 HP 11/2 HP
75
m3/hr
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM FEET PIES 120
Model SSH / 9SH Size (Tamaño) 1 x 2 - 6 RPM 2900 Curve (Curva) CN0621R00
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
50
40
A 65/8" DIA.
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
4'
B 6 /16" 7
100
55
A 65⁄8" 3 B 67⁄16 3 C 511⁄16 2 D 53⁄8 2
5’ NPSHR – FEET (PIES) 56 7'
C 511/16"
55 EFF%
80 D 53/8"
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
60
3 HP 40
2 HP
/2 HP
1
20
0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
20
40
80
60
100
U.S. GPM 120
CAPACITY (CAPACIDAD) (Q)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
FEET PIES 250
A 827⁄64" 5 B 81⁄16 5 C 711⁄16 5 D 73⁄8 5 E 71⁄8 3
5’ NPSHR – FEET (PIES)
200
42
7'
A 827/64" DIA.
47
B 81/16" 150
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 10SH Size (Tamaño) 1 x 2 - 8 RPM 2900 Curve (Curva) CN0615R00
9’
12’
C 711/16"
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
49 EFF%
D 73/8" E 71/8" 100
5 HP 3 HP
50
0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
25
50
75
100
125
U.S. GPM
150
CAPACITY (CAPACIDAD) (Q) PAGE 13
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM FEET PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
300
Model SSH / 11SH Size (Tamaño) 1 x 2 - 10 RPM 2900 Curve (Curva) CN0618R00 30
A 103/32" DIA.
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
NPSHR – FEET (PIES) 8’
250
A 103⁄32" 15 B 917⁄32 10 C 91⁄8 10 D 8¾ 7½
18'
38 14’
B 917/32"
20'
43
45
C 91/8"
NOTE: Pump will pass a sphere to 1⁄8" diameter. NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
43 EFF%
200 D 83/4"
150
10 HP 100
50
71/2 HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
25
50
75
100
150 U.S. GPM 175
125
CAPACITY (CAPACIDAD) (Q)
METERS FEET METROS PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
40
4’ NPSHR – FEET (PIES) 120
55
A 63/4" DIA.
6'
60 61 62
B 63/8" 30
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 4SH Size (Tamaño) 11/2 x 21/2 - 6 RPM 2900 Curve (Curva) CN0490R01
A 6¾" 5 B 63⁄8 5 C 61⁄16 5 D 55⁄8 3 E 55⁄16 3 F 411⁄16 2 G 43⁄8 2 H 43⁄16 1½
64
100 C 61/16" 64 8' D 5 /8" 5
80
62 61 EFF%
E 5 /16" 5
20 60
F 411/16" G 43/8" H 43/16"
NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
5 HP
40
3 HP
10 2 HP
20 1 HP
0
0 0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
40 10
80
120 20
160 30
CAPACITY (CAPACIDAD) (Q)
PAGE 14
200 40
U.S. GPM 50 m3/hr
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM METERS FEET METROS PIES 60
200 A 81/4" DIA.
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 7SH Size (Tamaño) 11/2 x 21/2 - 8 RPM 2900 Curve (Curva) CN0493R00 39
6’ NPSHR – FEET (PIES) 49
50
40
B 713/16"
54
160
55 56
A 8¼" 10 B 713⁄16 7½ C 7 7½ D 6¾ 7½ E 67⁄16 5 F 61⁄8 5
8' 57 58 13'
C 7"
17'
D 63/4" 120 E 67/16"
58
F 61/8"
57
30
NOTE: Pump will pass a sphere to 3⁄16" diameter. NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
56 EFF% 10 HP
71/2 HP
80 20 5 HP
10
0
40
0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
40
0
80
10
120
160
20
U.S. GPM
200
30
m3/hr
50
40
CAPACITY (CAPACIDAD) (Q)
40 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 5SH Size (Tamaño) 2 x 21/2 - 6 RPM 2900 Curve (Curva) CN0496R01
METERS FEET METROS PIES
49 5’ NPSHR – FEET (PIES)
A 67/8" DIA.
59
120
64 7'
B 6 /16" 7
66 67 30
100
68
10'
C 513/16" 80
68 14' 67
D 51/2"
66 EFF%
E 51/8" 20
10 HP
F 413/16" 60 G 47/16"
71/2 HP
40
A 67⁄8" 10 B 67⁄16 7½ C 513⁄16 7½ D 5½ 5 E 51⁄8 5 F 413⁄16 3 G 47⁄16 3 NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
5 HP
10 3 HP
20
0
0 0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
40 10
80 20
120 30
160
200 40
280
240 50
60
320 70
360 U.S. GPM 80
m3/hr
CAPACITY (CAPACIDAD) (Q)
PAGE 15
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
METERS FEET METROS PIES
6’ NPSHR – FEET (PIES)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
A 81/4" DIA. 50
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 8SH Size (Tamaño) 2 x 21/2 - 8 RPM 2900 Curve (Curva) CN0499R01 49
B 73/4"
59
A 8¼" 15 B 7¾ 15 C 7½ 10 D 73⁄16 10 E 67⁄8 7½ F 63⁄16 7½
7'
64
160 C 7 /2" 1
68
D 73/16"
70
9'
E 67/8"
13'
71
40
70
120 F 63/16"
16' 68
30
64 EFF% 15 HP
80
NOTE: Pump will pass a sphere to 5⁄32" diameter. NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
20 10 HP
40
71/2 HP
10
0
0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
80
40
0
10
120 20
160
30
200 40
240 50
360 U.S. GPM
320
280 70
60
80
m3/hr
CAPACITY (CAPACIDAD) (Q)
METERS FEET METROS PIES
6’ NPSHR – FEET (PIES)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
175 50 A 75/16" DIA.
64
B 71/8" C 615/16"
7' 69 69
8' 67
125 D 611/16"
11'
E 63/8" 30
A 75⁄16" 15 B 71⁄8 15 C 615⁄16 15 D 611⁄16 10 E 63⁄8 10 F 61⁄16 7½ G 55⁄8 7½
58 150
40
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 6SH Size (Tamaño) 21/2 x 3 - 6 RPM 2900 Curve (Curva) CN0501R00
100
65
F 61/16"
13' 17' 64
G 55/8"
62
75
58 EFF%
20 50
15 HP
10
10 HP
25
71/2 HP
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0 0
100 25
300
200 50
400 75
CAPACITY (CAPACIDAD) (Q)
PAGE 16
NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
21'
600 U.S. GPM
500 100
125
m3/hr
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM METERS FEET METROS PIES 450
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
130 120 110
A 9 7/8" DIA.
400
50% EFF
6’ NPSHR – FEET (PIES) 55
B 9 1/2"
350
57
D 8 7/8"
90
300 E 8 9/16"
10'
59 60
12'
59
55
F 8 1/4" 250
70 60 50
A B C D E F
8'
C 9 3/16"
100
80
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 24SH Size (Tamaño) 11/2 x 21/2 - 10 RPM 3500 Curve (Curva) CN0503R00
30 H
200
25 H 20 H
150
97⁄8" 30 9½ 30 93⁄16 25 87⁄8 25 89⁄16 20 8¼ 20
NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
P
P
P
40 30
100
20 10
50 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
50
100
0
150
250
200 40
20
U.S. GPM 60
300 m3/hr
CAPACITY (CAPACIDAD) (Q)
Model SSH / 25SH Size (Tamaño) 2 x 21/2 - 10 RPM 3500 Curve (Curva) CN0506R00
METERS FEET METROS PIES 450
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
130 120 110
D 8 /16" 13
300
80
E 8 3/16" F 7 15/16" 250 G 711/16"
50
11'
64
C 9 1/8"
90
60
60 62 9' 63
B 9 /2" 1
100
70
55% EFF
400
350
64
20' 63 50 H 40 H
200 30 H
150
25 H
40 30
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
7’ NPSHR – FEET (PIES)
A 9 7/8" DIA.
P
P
P
A 97⁄8" 50 B 9½ 40 C 91⁄8 40 D 813⁄16 30 E 83⁄16 30 F 715⁄16 25 G 711⁄16 25 NOTE: Pump will pass a sphere t o ½" diameter. NOTA: La bomba pasará una esfera a ½" diámetro.
P
100
20 10
50 0 0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
50
100 20
150
200 40
300
250 60
350 80
400
450 U.S. 500 100
GPM m3/hr
CAPACITY (CAPACIDAD) (Q)
PAGE 17
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
60
A 9 1/16" DIA. 3 325 B 8 /4"
10'
65
A 91⁄16" 60
12' 15'
68
C 8 1/2"
300
70
D 8 1/4"
275 80
50
B 8¾ 50
20'
25' 30'
65
250 E 7 /8" 7
60
225 F 7 /2"
60
200 G 7 1/8"
50
11 175 H 6 /16" J 61/2"
1
D 8¼ 40 F
7½
30
H 611⁄16 20 J 6½ 20 60 15
125
HP
NOTE: Pump will pass a sphere to 19⁄32" diameter. NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
HP
75
25
HP 20 HP 600
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
100 0
200 40
300 60
400
500
80
100
30
120
HP
100
50
50
G 71⁄8 25
HP
20
8½
40
30
150 40
C
E 77⁄8 40
71
70
68
50
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
90
7’ NPSHR – FEET (PIES) 8'
40% EFF
350 100
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 22SH Size (Tamaño) 21/2 x 3 - 8 RPM 3500 Curve (Curva) CN0509R00
METERS FEET METROS PIES
HP
700
140
800 180
160
U.S. GPM m3/hr
CAPACITY (CAPACIDAD) (Q)
Model SSH / 27SH Size (Tamaño) 21/2 x 3 - 10 RPM 3500 Curve (Curva) CN0512R00
METERS FEET METROS PIES
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
600 175
7’ NPSHR – FEET (PIES)
550 150
45% EFF
500
100
60
A 103⁄8" 100 B 915⁄16 75
10' 12'
65
A 1 03/8" DIA.
450 125
55
8'
C 99⁄16
15'
69
20'
B 9 /16" 15
70
400 C 9 9/16" D 9 1/4"
350
10
E 8 3/4" 40
250
H
25
50
150
P
HP
HP
100
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
100 20
200 40
300 60
400 80
500 100
120
CAPACITY (CAPACIDAD) (Q)
PAGE 18
NOTE: Pump will pass a sphere to 19⁄32" diameter. NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
P
60
50 0
0H
75 65 HP
200 50
E 8¾ 50
69
300 75
30'
600 140
75
D 9¼ 60
700
800
U.S. GPM
160
180
m3/hr
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
10' 50% EFF
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
350 100 90 80
NOTE: Not recommended for operation beyond printed H-Q curve.
Model SSH / 23SH Size (Tamaño) 3 x 4 - 8 RPM 3500 Curve (Curva) CN0515R00
METERS FEET METROS PIES
60
A 9 1/16" DIA.
12’ NPSHR – FEET (PIES) 14' 70
325
B 8 11/16"
75
A 91⁄16" 75
17' 77
300 C 8 7/16"
20' 78
275 D 8 1/16"
B 811⁄16 75 C 87⁄16 60
78 25' 77
60
75
H 67/8" J 6 1/2"
60
150
20
0
70 50
125 K 6 " 100
40
L 5 1/2"
75 15
50
HP
E 711⁄16 50
F 7½ 40
G 71⁄8 40
G 7 1/8"
200 175
30
10
75
1 225 F 7 /2"
50 40
D 81⁄16 50
30'
250 E 7 11/16" 70
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
200
0
40
400 80
600 120
HP
200
K 6 20
HP
L 5½ 15 NOTE: Pump will pass a sphere t o ¾" diameter. NOTA: La bomba pasará una esfera a ¾" diámetro.
HP
1000
160
J 6½ 25
HP
3 25 0 HP H 20 HP P
800
H 67⁄8 30
HP
1400
1200
240
280
320
1600 360
U.S. GPM m3/hr
CAPACITY (CAPACIDAD) (Q)
Model SSH / 28SH Size (Tamaño) 3 x 4 - 10 RPM 3500 Curve (Curva) CN0518R00
METERS FEET METROS PIES
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
600 TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
175
C 913⁄16" 100 D 97⁄16 100 E 91⁄16 75 F 811⁄16 75
550 150
500
45% EFF
450 125
C 9 13/16" DIA.
400
8’ NPSHR – FEET (PIES) 10' 55 12' 65 14' 70 73
75
D 9 7/16" 100
75
25
NOTE: Pump will pass a sphere t o ¾" diameter. NOTA: La bomba pasará una esfera a ¾" diámetro.
25' 75
30'
73
300 F 8 /16" 11
250
60
10 H
P
75
0H
P
HP
150 100 50
0
20' 76
350 E 9 1/16"
200 50
17' 76
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
200 40
400 80
600 120
800 160
1000 200
1200
240
280
1400 320
1600 360
U.S. GPM m3/hr
CAPACITY (CAPACIDAD) (Q)
PAGE 19
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 24SH Size (Tamaño) 11/2 x 21/2 - 10 RPM 1750 Curve (Curva) CN0505R00
METERS FEET METROS PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
110 30
A 9 7/8" DIA.
100
45% EFF
50
90 B 9 /2" C 93/16" 1
25
52
A 97⁄8" 4'
54
C 93⁄16
56
80 D 8 /8"
54
E 8 9/16" 20
70 F 8 1/4"
5'
50
50
3H
3
D 87⁄8 3
E 89⁄16 3
52
F 8¼ 2 NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
60 15
5
B 9½ 5
7
P
40 10
2H
P
30 20
5 10
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
20
10
0
30
40
5
10
110
60
70
80
100 B 9 1/2" 90
25
20
15
100
90
110
15 20 CAPACITY (CAPACIDAD) (Q)
4’ NPSHR – FEET (PIES) 50% EFF 55 57
A 9 7/8" DIA. 30
50
120
130
25
30
150 140 U.S. GPM m3/hr
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 25SH Size (Tamaño) 2 x 21/2 - 10 RPM 1750 Curve (Curva) CN0508R00
METERS FEET METROS PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
3’ NPSHR – FEET (PIES)
A 97⁄8" 7½
58
B 9½ 5
5'
59
C 9 1/8" 80 D 8 13/16"
59
58
70 E 8 3/16" F 7 15/16" 60 G 711/16"
C 91⁄8 5
8' 7.5 HP
5
5H
50
30
P
3H
0 0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
20 5
40 10
60 15
120
100
80 20
25
140 30
CAPACITY (CAPACIDAD) (Q)
PAGE 20
P
20 10
5
E 8 ⁄16 3 3
F 715⁄16 3
40 10
D 813⁄16
160 35
180 40
200 45
240 U.S. GPM 50 m3/hr 55
220
G
711⁄16 3
NOTE: Pump will pass a sphere t o ½" diameter. NOTA: La bomba pasará una esfera a ½" diámetro.
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 1725 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 1725 RPM Model SSH / 22SH Size (Tamaño) 21/2 x 3 - 8 RPM 1750 Curve (Curva) CN0511R00
METERS FEET METROS PIES
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
120 35
A 91⁄16" 7½
110 30
C 8½ 7½
100
90 25
40% EFF 50
60
8'
62
70
64
D 8 1/4"
15
NOTE: Pump will pass a sphere to 19⁄32" diameter. NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
10'
62
60 E 7 7/8" 50
5
H 611⁄16 3
C 8 1/2"
20
8¼
G 71⁄8 3
6'
55
80 A 9 1/16" DIA.
D
E 77⁄8 5
5’ NPSHR – FEET (PIES)
60
15'
55
50
G 7 1/8"
40 H 6 11/16" 10
5
2
30
71 /2 H P
20 5
10 0
HP
0
3
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
50 10
0
100 20
150
200
250
40
30
50
300 60
450 U.S. GPM 100 m3/hr
400
350
70
HP
HP
80
90
CAPACITY (CAPACIDAD) (Q)
METERS FEET METROS PIES
Model SSH / 27SH Size (Tamaño) 21/2 x 3 - 10 RPM 1750 Curve (Curva) CN0514R00 50% EFF
35 110
55
60
A 1 03/8" DIA.
63
5' NPSHR – FEET (PIES)
66
68
B 9 /16" 15
30
100 90
25
68
C 9 9/16"
80
A 103⁄8" 15
7'
B 915⁄16 10
10'
C 99⁄16
15'
66
D 9 1/4" E 8 /4"
20'
63
E 8¾ 7½
3
60
70
15
20
H
55
P
60
10
D 9¼ 7½
NOTE: Pump will pass a sphere to 19⁄32" diameter. NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
5
50
P
15
H 10 H
40
P
P H
5
/
10
1 2
7
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
120
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
30 20 10
0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
50 10
100 20
150 30
200 40
250 50
300 60
70
350 80
400 90
450 U.S. GPM 100 m3/hr
CAPACITY (CAPACIDAD) (Q)
PAGE 21
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 60 HZ, 1725 RPM CURVAS DE FUNCIONAMIENTO – 60 HZ, 1725 RPM Model SSH / 23SH Size (Tamaño) 3 x 4 - 8 RPM 1750 Curve (Curva) CN0517R00
METERS FEET METROS PIES
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
120 35
A 91⁄16" 10
110 30
25
20
15
5
D 81⁄16 7½
45% EFF 90 55 1 80 A 9 /16" DIA.
5’ NPSHR – FEET (PIES)
65
68
50
8'
73
15' 73
F 7 1/2"
71 68
G 7 /8" 1
65
J 6 1/2"
55
30 3
20
5H
0 0
100 20
0
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
METERS FEET METROS PIES
40
35
200 40
300 60
400
500
600
80 100 120 CAPACITY (CAPACIDAD) (Q)
130
700
65
120 A 105/8" DIA.
160
B 10¼ 15 C 913⁄16 15
70 8'
73
D 97⁄16 15 10'
100 C 9 13/16"
74
20'
73 70
H
P
20
50
15
40
H
H
P
P
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
100 20
200 0
300 60
400 80
500 100
120
600 140
CAPACITY (CAPACIDAD) (Q)
PAGE 22
30' 65
10
60
20 0
NOTE: Pump will pass a sphere to ¾" diameter. NOTA: La bomba pasará una esfera a ¾" diámetro.
15'
80
30
180
7’ NPSHR – FEET (PIES)
20
10
900 U.S. GPM 200 m3/hr
800
A 105⁄8" 20
45% EFF 55
70
15
P
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
7 90 D 9 /16"
25
140
HP
Model SSH / 28SH Size (Tamaño) 3 x 4 - 10 RPM 1750 Curve (Curva) CN0520R00
110 B 1 01/4" 30
10
71 /2 H P
HP
10 0
J 6½ 3 NOTE: Pump will pass a sphere t o ½" diameter. NOTA: La bomba pasará una esfera a ½" diámetro.
10'
74
D 8 1/16"
F 7½ 5
G 71⁄8 5
6'
71
70 C 8 7/16"
40 10
C 87⁄16 7½
100
60
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
700 160
800 180
900 U.S. GPM 200 m3/hr
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM METERS FEET METROS PIES
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
90 80
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 24SH Size (Tamaño) 11/2 x 21/2 - 10 RPM 2900 Curve (Curva) CN0504R00
300
A 9 7/8" DIA. 48% EFF 250 B 9 1/2"
3’ NPSHR – FEET (PIES) 6' 53 55 57
8'
C 9 3/16"
70
58
D 8 7/8" 60
9 200 E 8 /16"
F 8 1/4"
50 150 40 30
100
10 H
A 97⁄8" 20 B 9½ 15 C 93⁄16 15 10' D 87⁄8 15 57 55 E 89⁄16 10 53 20 HP F 8¼ 10 NOTE: Pump will pass a sphere to ½" diameter. NOTA: La bomba pasará 15 una esfera a ½" diámetro. HP
P
20 50 10
0 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
20
0
80
10
100
120
140
160
180
20 30 CAPACITY (CAPACIDAD) (Q)
220 U.S. 240 GPM m3/hr 50
200
40
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 25SH Size (Tamaño) 2 x 21/2 - 10 RPM 2900 Curve (Curva) CN0507R00
METERS FEET METROS PIES 90
60
40
300
6’ NPSHR – FEET (PIES)
A 9 7/8" DIA.
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
53% EFF 80 250
62
C 9 1/8"
70
60
A 97⁄8" 30
58 60 8' 61
B 9 /2" 1
B 9½ 25
10'
D 8 /16"
C 91⁄8 20
13
200
50
62
61
E 8 3/16" F 7 15/16" G 711/16"
30 H 25 H
150 40 30
D 813⁄16 20
17'
100
F 715⁄16 15 P
P
20 H 15 H
E 83⁄16 15
P
G
711⁄16 15
NOTE: Pump will pass a sphere to 5⁄16" diameter. NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
P
20 50 10 NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
0 0
40
80 20
120
160
200 40
240
280 60
320
360 U.S. 400 GPM 80 m3/hr
CAPACITY (CAPACIDAD) (Q) PAGE 23
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM Model SSH / 22SH Size (Tamaño) 21/2 x 3 - 8 RPM 2900 Curve (Curva) CN0510R00
METERS FEET METROS PIES 250
60
40% EFF 50
A 9 1/16" DIA. 225 B 8 3/4"
6’ NPSHR – FEET (PIES) 8' 60 7' 65
C 8 1/2"
15'
67
B 8¾ 30 18'
65
G 71⁄8 15 40
G 7 /8" H 6 /16" J 61/2"
100
50 25
HP
75
20
50
0
HP
11
15
10
E 77⁄8 20
F 7½ 20
1
125
20
D 8¼ 25
68
F 7 1/2"
40
C 8½ 30 20'
60
175 E 7 7/8"
150
30
A 91⁄16" 40
12'
200 D 8 1/4"
50
10'
10
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
70
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
100 0
200
300
40
60
400 80
H
611⁄16
15
J
6½
15
NOTE: Pump will pass a sphere to 19⁄32" diameter. NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
HP
HP
HP
HP
600 U.S. GPM 700
500 100
30
140
120
m3/hr
CAPACITY (CAPACIDAD) (Q)
Model SSH / 27SH Size (Tamaño) 21/2 x 3 - 10 RPM 2900 Curve (Curva) CN0513R00
METERS FEET METROS PIES 400
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
45% EFF 350
6’ NPSHR – FEET (PIES)
55
100
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
8'
60 65
A 1 0 /8" DIA. 3
10'
68
300 B 9 15/16"
A 103⁄8" 50 C 99⁄16 40
15' 69
C 9 9/16" 75
B 915⁄16 40
12' 68
20' 65
250 D 9 1/4" E 8 3/4"
50
200 25
50
H
40
P
150 30
100
HP
HP
HP
50
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
100 20
200 40
300 60
400 80
CAPACITY (CAPACIDAD) (Q)
PAGE 24
600 U.S. GPM
500 100
120
D
E 8¾ 30
9¼
30
Pump will pass a sphere to 19⁄32" diameter. NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
25
0
140
700
m /hr 3
Goulds Water Technology Commercial Water PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM Model SSH / 23SH Size (Tamaño) 3 x 4 - 8 RPM 2900 Curve (Curva) CN0516R00
METERS FEET METROS PIES 250
50% EFF
70
60
A 9 1/16" DIA.
9'
10’ NPSHR – FEET (PIES)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
225
12' 72
70
B 8 11/16" 60
C 8 /16" 7
200
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
74
B 811⁄16 40
76 D 8 1/16"
50
A 91⁄16" 50
15'
E 7 /16" 11
72
F 7 1/2"
50
G 7 1/8"
40
7 125 H 6 /8"
40
J 6 1/2"
70
75
25 20
50
15
10 0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0
200
0
40
400
600 120
80
30
E 711⁄16 30
F 7½ 25
G 71⁄8 20
HP
H 67⁄8 20 J 6½ 15 NOTE: Pump will pass a sphere t o ½" diameter. NOTA: La bomba pasará una esfera a ½" diámetro.
HP
100
30 20
D 81⁄16
74
175
150
30
C 87⁄16 40
20'
76
HP
HP
HP
HP
800
1200 U.S. GPM 1400
1000
160
200
240
280
m3/hr
CAPACITY (CAPACIDAD) (Q)
TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)
Optional Impeller, Impulsor Opcional Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
Model SSH / 28SH Size (Tamaño) 3 x 4 - 10 RPM 2900 Curve (Curva) CN0519R00
METERS FEET METROS PIES 400
350
C 913⁄16" 60
100 300 C 9 13/16" DIA. 75
50% EFF 8’ NPSHR – FEET (PIES) 9' 60 10' 65 12' 70 73
E 91⁄16 50 F 811⁄16 40
14' 75
E 9 /16" 1
73
F 8 11/16"
200
30
50 150
H
NOTE: Pump will pass a sphere t o ¾" diameter. NOTA: La bomba pasará una esfera a ¾" diámetro.
17'
75
D 9 7/16"
250
D 97⁄16 50
20'
60 P 40
50 H
H
H
P
P
P
100 25 50
0
0
NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
0 0
200 40
400 80
600 120
800 160
1200 U.S. GPM 1400
1000 200
240
280
m3/hr
CAPACITY (CAPACIDAD) (Q)
PAGE 25
Goulds Water Technology Commercial Water SSH CLOSE COUPLED – MATERIALS OF CONSTRUCTION SSH ACOPLE CERRADO – MATERIALES DE CONSTRUCCIÓN 101
100
178
108
103
SSH FRAME MOUNTED – MATERIALS OF CONSTRUCTION SSH ARMAZÓN MONTADO – MATERIALES DE CONSTRUCCIÓN 101
100
370
513
370
184
383 108
228
412A
513
134 184
370C 333A
412A
383
199 422 408 412F 126 Item No., Description, Parte No. Descripción 100
371 Materials, Materiales
Casing, Carcasa
101 Impeller, Impulsor
126 199 422 408 178412F 370B 123 168 112 382 Item No., Description, Materials, Parte No. Descripción Materiales
103
100 316L SS, 316L acero inox.
103
Wear ring, Anillo de desgaste
184
Seal housing, Alojamiento del sello
126
Shaft sleeve, Camisa del eje
316 SS, 316 acero inox.
422
Impeller stud, Perno del impulsor
Steel, Acero
178
Impeller key, Llave del impulsor
Carbon steel, Acero al carbono
199
Impeller washer, Arandela del impulsor
316 SS, 316 acero inox.
370
Casing bolt with nut (casing to adapter), 316L SS, Tornillo de la carcasa con tuerca 316L acero inoxidable (carcasa para adaptador)
108 Adapter, Adaptador
Cast iron ASTM A48 CL20, Hierro fundido ASTM A48CL20
371
Hex head cap screw (adapter to motor), Tornillo de cabeza hexagonal (adaptador para motor)
Steel SAE 1200 series, Acero SAE series 1200
412A
O-ring, Impeller, Anillo en O, impulsor
412F
122
Casing, Carcasa
101 Impeller, Impulsor
316L SS, 316L acero inox.
103
Wear ring, Anillo de desgaste
184
Seal housing, Alojamiento del sello
126
Shaft sleeve, Camisa del eje
316 SS, 316 acero inox.
178
Impeller key, Llave del impulsor
422
Impeller Stud, Perno del impulsor
Carbon steel, Acero al carbono
199
Impeller washer, Arandela del impulsor
316 SS, 316 acero inox.
370 408
Casing bolt with nut, Tornillo de la carcasa con tuerca 316L SS, 316L acero inox.
Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT
513 O-ring, Anillo ‘O’ Viton 383
Mechanical seal, Sello mecánico
See seal chart, Ver tabla del sello
228
Bearing frame, Armazón de balineras
134
Bearing cover, Cubierta de balineras
Cast iron ASTM A48CL20, Hierro fundido ASTM A48CL20
O-ring, shaft sleeve, Anillo en O, camisa del eje Viton
122
Pump shaft, Eje de la bomba
Carbon steel, Acero al carbono
513
O-ring, Anillo 'O'
168
Ball bearing (inboard), Balineras de bolas (interior)
408
Drain plug – 3⁄8 BSP, Válvula de drenaje – 3⁄8 BSP
316L SS, 316 acero inoxidable
112
Ball bearing (outboard), Balineras de bolas (exterior)
Mechanical seal, Sello mecánico
See seal chart, Ver tabla del sello
382
Retaining ring, Anillo de sujeción
370B
Hex head cap screw (adapter to bearing frame), Tornillo de cabeza hexagonal (adaptador para armazón de balineras)
370C
Hex head cap screw (bearing frame to cover), Tornillo de cabeza hexagonal (armazón de balineras para cubierta)
383
Mechanical Seal, Sello Mecánico John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21 Part No., Pleza Número Item, Rotary, Stationary, Elastomers, 180-210 250-360 Rotativo Estacionario Elastómeros Parte Frames, Frames, Armazones Armazones
Metal
Intended Parts, Duty, Partes Servicio Metálicas Propuesto
Hot Water, 10K19 10K20 EPR 383 Carbon, Silicon 316 SS, Agua Caliente Options, Carbone Carbide, 316 Mild Abrasive, 10K27 10K45 Carburo de Acero Abrasivo Suave 383 Viton inoxidable Severe Duty, Opciones silicona 10K64 10K65 Sil-Carb. Deber Severo PAGE 26
108 Adapter, Adaptador
Steel, Acero
333A
Lip seal, Sello cubierto BUNA-N
193
*Grease fitting, Accesorio de grasa Steel, Acero
123
V-ring deflector, Deflector anillo ‘V’ BUNA-N
* M-Group only
Goulds Water Technology Commercial Water SSH – ENGINEERING DATA SSH – INFORMACIÓN TÉCNICA
S-GROUP GRUPO-S
Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End; Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor DISCHARGE DESCARGA
AB MAX.
CP
PRIME PLUG SUCTION SUCCIÓN
HE HA
SPACER COUPLING ACOPLE DEL ESPACIADOR COUPLING GUARD, GUARDA ACOPLE
DC DD MAX.
SINGLE PHASE ONLY, SOLO UNIFÁSICOS
KEYWAY 1⁄8 x ¼ CHAVETERO 1⁄8 x ¼
(4) HOLES 5 P ⁄8 DIA. MAX. (4) AGUJEROS 5 ⁄8 DIA.
HG
DRAIN PLUG HE
CREF
3½ 1.125 Ø 1.124
X
HD
3¾
Z
Y
⁄8" – 19 BSP
3
HL
HP
HF HB
Dimensions and Weights – Determined by Pump, Dimension “HL” Determined Dimensiones y Pesos – Determinados por la Bomba by Pump and Bedplate, Dimensión “HL” determinada la bomba y el motor Motor Frame Size, Tamaño del bastidor del motor Pump, Bomba Suction*, Discharge*, CP DC Max., DD X Y Z Wt. (lbs.), 143/ 183/ 213/ 254/ 284/ Sución* Descarga* DC Máx. Peso (lib.) 145 184 215 256 286 9SH 1 X 2–6 5 4¾ 63⁄8 1 56 1 3 5 7 16 ⁄4 3 ⁄8 7 9 ⁄8 7 ⁄8 3 ⁄8 10SH 1 X 2–8 2 1 55⁄8 53⁄8 71⁄8 3 ⁄8 64 9 7 5 7 11SH 1 X 2–10 17 ⁄16 6 ⁄8 6 ⁄8 8 ⁄8 4 86 10 8½ 4¾ 4SH 1½ X 2½–6 169⁄16 5 4¾ 63⁄8 3¼ 57 9¼ 7¾ 4 1½ 7SH 1½ X 2½–8 55⁄8 53⁄8 66 1 2½ 7 ⁄8 5SH 2 X 2½–6 5 4¾ 35⁄8 57 2 175⁄16 4 10 8½ 4¾ 8SH 2 X 2½–8 68 6 5¾ 715⁄16 6SH 2½ X 3–6 3 2½ 59 * For use with ANSI Class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150. Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundación y del Motor
NOTES: 1. All pumps shipped in vertical discharge position. May be rotated in 90° increments. Tighten 38 ⁄ – 16 casing bolts to 12 ft./lbs. torque. 2. Dimensions in inches. 3. Motor dimensions may vary with motor manufacturer. 4. Not to be used for construction purposes. NOTAS: 1. Todas las bombas transportadas en posición de descarga vertical. Pueden rotarse en aumentos de 90º. Apretar 3⁄8 – 16 tornillos de carcasa a 12 pies/libras potencia. 2. Las dimensiones en pulgadas. 3. Las dimensiones puede que varíen con los fabricantes.. 4. No para propósitos de construcción.
HP @ 3500 RPM, HP @ 1750 RPM, Motor HP a 3500 RPM HP a 1750 RPM Frame, Single Phase, Three Phase, Armazón Single Phase, Three Phase, del Monofásicos Trifásicos Monofásicos Trifásicos Motor ODP TEFC ODP TEFC ODP TEFC ODP TEFC
Bedplate Data, Datos de la Fundación AB P Wt. Max., CREF Max., Max., Wt. (lbs.), Motor Bearing AB P Peso HA HB HD** HE HF HG HP* Frame Máx. Máx. Máx. Peso Shim Shim (libras) 143T 1 1 1 1 133⁄8 45 5 5¼ 6 ⁄8 1¾ 145T 2 2 2 – 3 2 1½ 1½ 1½ – 2 1½ – 2 14¼ 53 10 28 8 3¾ 24 2¾ ¾ 48 — 182T 3 3 5 3 2 2 3 3 7 165⁄8 74 5 ⁄8 77⁄8 ¾ 184T 5 5 7½ 5 3 or 5 3 5 3 181⁄8 95 213T 10 7½ 3 18 5 116 7 ⁄8 9 ⁄8 12 31 8¼ 4¼ 29 3 1 65 215T 15 10 191⁄8 136 254T 20 15 1 215⁄8 266 10 ⁄8 13 13 42 10¼ 5¼ 38½ 4 256T 25 20 233⁄8 264 1¾ 284TS 30 25 5 247⁄8 392 12 ⁄8 15 15 44 10½ 5¾ 40½ 3½ 286TS 40 30 265⁄8 432
—
—
110
—
1
124
–
1¾
Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. * “HP” Dimensions at motor end only. ** “HD” Dimension for 254T/256T motor frame on 1 x 2-10 only is 11"; A ¾" motor shim and a 1¾" bearing frame shim are required. Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras. * Dimensiones “HP” sólo en el extremo del motor. ** La dimensión “HD” para el bastidor del motor 254T/256T de 1 x 2 - 10 es sólo 11"; se requieren una cuña del motor de ¾" y una cuña del bastidor de apoyo de 1¾". PAGE 27
Goulds Water Technology Commercial Water SSH-F – ENGINEERING DATA SSH-F – INFORMACIÓN TÉCNICA
M-GROUP GRUPO-M
Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End; Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor C REF.
CP
DISCHARGE
AB MAX.
33/4
415/16
Y
SPACER COUPLING PRIME PLUG
37/8
COUPLING GUARD
1.625 1.624
SINGLE PHASE ONLY
SUCTION PMAX. DC DD
4 HOLES
KEYWAY
MAX.
5
3/16 X 3/8
HD
/8
HG
DRAIN PLUG HE
HE
3 3/8” GAS ⁄8" THREAD – 19 BSP UNI ISO 228/1
HA
13/4
HF
L HB
NOTE: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position and tighten 3⁄8 – 16 bolts to 12 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes.
Dimensions and Weights – Determined by Pump, Dimensiones y Pesos – Determinados por la Bomba Wt. DC Pump Size, Max., DD L X Y (lbs.), Suction*, Discharge*, Tamaño de CP DC Pump Peso Descarga* la Bomba Succión* Máx. (libras) 24SH 1½ x 2½-10 1½ 125 7 2½ 6 ⁄8 65⁄8 25SH 2 x 2½-10 2 1 815⁄16 125 23 10 ⁄8 4 22SH 2½ x 3-8 61⁄8 57⁄8 125 3 2½ 27SH 2½ x 3-10 15 134 67⁄8 65⁄8 9 ⁄16 23SH 3 x 4-8 1 136 4 3 24 11 ⁄ 8 5 28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148
NOTA: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.
* For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.
Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundación y del Motor HP @ 3500 RPM Motor Frame, Three Phase, Armazón Trifásicos del Motor ODP TEFC
HP @ 1750 RPM – T-Frame Only
ODP
TEFC
ODP
TEFC
184T
3 or 5
3
5
5 7½
Single Phase, Three Phase, Monofásicos Trifásicos
AB P Wt. Max., C Max., Max., AB Ref. P Peso Máx. Máx. Máx. 57⁄8 181⁄8
Bedplate Data, Datos de la Fundación HA
HB
HD
HE
HF
HG
Wt. (lbs.), Peso (libras)
77⁄8 95
213T
7½
215T
15
10
18 5 116 73⁄8 9 ⁄8 10 191⁄8 136 13 42 101⁄4 51⁄4 38½ 4 111
254T
20
15
15
15
256T
25
20
20
215⁄8 266 91⁄2 13 3 20 23 ⁄8 264
284TS/T
30
25
25
25
247⁄8 392 125⁄8 15 15 44 10½ 5¾ 286TS/T 40 30 265⁄8 422
40½ 3½ 124
324TS/T 50 40 1 283⁄4 592 14 ⁄8 173⁄8 12 326TS/T 60 50 30¼ 634 18 48 7¼ 44½ 4 183 364TS/T 75 60 1 315⁄8 834 15 ⁄8 187⁄8 13 365TS/T 100 75 325⁄8 1000 405TS/T 100 18 367⁄8 Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras. PAGE 28
205⁄8 1060 22 56 14 7¼ 52½ 4 214
Goulds Water Technology Commercial Water SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS SSH ACOPLE CERRADO – DIMENSIONES Y PESOS
S-GROUP GRUPO-S
(All dimensions in inches and weights in lbs. Do not use for construction purposes.) (Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)
DISCHARGE DESCARGA
AB MAX.
Y
CREF
Z
PRIME PLUG X SUCTION SUCCIÓN P MAX. G
DC DD MAX.
DRAIN PLUG
E
E
D
A
L 3 ⁄8" – 19 BSP
150 lb. Flange, DC Wt. DIM. “L” (Motor Frame Size) Brida de 150 lib. Max., Pump, DIM. “L” (Tamaño del Armazón del Motor) (lbs.), DD X Y Z Bomba DC Pesos Suct.*, Disch.*, Máx. 143/145 182/184 213/215 254/256 (libras) Succ.* Desc.* 9SH 1 x 2 – 6 5 4¾ 63⁄8 3 24 31⁄8 9 ⁄8 10½ 11½ — 5 3 10SH 1 x 2 – 8 2 1 5 ⁄8 5 ⁄8 71⁄8 37⁄8 32 11SH 1 x 2 – 10 67⁄8 65⁄8 87⁄8 4 10¾ 113⁄8 123⁄8 125⁄8 54 4SH 1½ x 2½ – 6 5 4¾ 63⁄8 3¼ 9¾ 103⁄8 113⁄8 — 25 1½ 7SH 1½ x 2½ – 8 55⁄8 53⁄8 71⁄8 34 2½ 5SH 2 x 2½ – 6 5 4¾ 71⁄8 4 35⁄8 25 2 10½ 111⁄8 121⁄8 123⁄8 8SH 2 x 2½ – 8 5¾ 15 36 6 7 ⁄16 6SH 2½ x 3 – 6 3 2½ 4¾ 27 * For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.
F
F
H-(4) HOLES H-(4) AGUJEROS
B
NOTE: 1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs. 2. ALL dimensions in inches. 3. Motor dimensions may vary with motor manufacturer. 4. Not for construction purposes. NOTA: 1. Las bombas se transportarán en descarga vertical como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. Las dimensiones puede que varíen con los fabricantes. 4. No para propósitos de construcción.
Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM
Motor Frame Selections, Selecciones del Armazón del Motor
P Motor Wt. H Max., (lbs.) CREF Dia., P Peso Motor H (lib.) Diám. Máx. 143JM 2 1 41 6½ 5¼ 6 3½ 2¾ ⁄8 11¼ 11⁄32 65⁄8 145JM 2½ 57 182JM 2¼ 3 7 77 8½ 67⁄8 6½ 4½ 3¾ ⁄16 13½ 7 ⁄8 184JM 97 13 2¾ ⁄32 213JM 7 5 122 9½ 73⁄8 8 5¼ 4¼ ⁄32 15½ 9 ⁄8 215JM 3½ 155 254TCZ 9½ 41⁄8 265 11¼ 9 6¼ 5 ¼ 185⁄8 17⁄32 11½ 256TCZ 11¾ 5 320
Motor Horsepower, Potencia del Motor Motor Frame, 3500 RPM, 3500 RPM 1750 RPM, 1750 RPM Armazón 1Ø, Monofásicos 3Ø, Trifásicos 1Ø, Monofásicos 3Ø, Trifásicos del Motor ODP TEFC ODP TEFC ODP TEFC ODP TEFC 143JM – – – – – – 1 1 145JM 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2 182JM 3 3 5 3 2 2-3 3 3 184JM 5 5 7½ 5 3 – 5 5 213JM 7½ – 10 7½ 5 – 7½ 7½ 215JM 10 – 15 10-15 – – – – 254TCZ – – 20 – – – – – 256TCZ – – 25 20 – – – –
JM Frame, JM Armazón
A
AB B
D
E
F
G
PAGE 29
Goulds Water Technology Commercial Water SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS SSH ACOPLE CERRADO – DIMENSIONES Y PESOS (All dimensions in inches and weights in lbs. Do not use for construction purposes.)
M-GROUP GRUPO-M
(Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.) CPMAX.
DISCHARGE
AB MAX.
415/16
Y
PRIME PLUG
SUCTION P MAX.
G
E
D
DC DD MAX.
DRAIN PLUG
E
L /8-19 BSP
3
A
F
F
H-4 HOLES
B
Dimensions “L” Determined by Pump and Motor, Dimensiones “L” Determinadas por la Bomba y el Motor CP Max., CP Máx.
Wt. DC Motor Frame Size, Max., (lbs.), Tamaño del Armazón del Motor DD X Y DC Peso Máx. (libras) 140 180 210 250 280 320 360 24SH 1½ x 2 ½-10 1½ 34½ 75 10½ — 2½ 67⁄8 65⁄8 25SH 2 x 2½-10 2 815⁄16 75 111⁄8 4 121⁄8 137⁄8 143⁄8 22SH 2½ x 3-8 36 61⁄8 57⁄8 72 — 15 3 2½ 27SH 2½ x 3-10 84 — — 67⁄8 65⁄8 915⁄16 23SH 3 x 4-8 86 11½ 121⁄8 4 3 37 5 133⁄8 147⁄8 153⁄8 16 28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 98 — — NOTES: NOTAS: * For use with ANSI class 150 mating flanges. 1. Las bombas se transportarán en descarga verti* Para usar con bridas que casan ANSI clase 150. 1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing cal como estándar. Para otras orientaciones, rebolts, rotate discharge to desired position, and tirar los tornillos de la carcasa, rotar la descarga tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to a la posición deseada, y apretar 3⁄8 – 16 tornillos 20 ft./lbs., ½ – 13 bolts to 35 ft./lbs. a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras, 2. Motor dimensions may vary with motor ½ – 13 tornillos a 35 pies/libras. manufacturer. 2. TODAS las dimensiones en pulgadas. 3. Not for construction purposes. 3. No para propósitos de construcción. Pump Size, Tamaño de la Bomba
Pump
Suction*, Discharge*, Succión* Descarga*
Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM Frame, Armazón
A
AB Max.
B
D
E
F
G
P Max., P Máx. 11 ⁄32 73⁄16 H
145JM 6½ 5¼ 6 3½ 2¾ 2½ 1⁄8 182JM 2¼ 3 8½ 57⁄8 6½ 4½ 3¾ ⁄16 8½ 184JM 13 2¾ ⁄32 213JM 7 9½ 73⁄8 8 5¼ 4¼ ⁄32 103⁄16 215JM 3½ 254JM 41⁄8 11¼ 9 11¾ 6¼ 5 13¼ 256JM 5 ¼ 17⁄32 284JM 4¾ 12¼ 12¼ 12¼ 7 5½ 15 286JM 5½ 324JM 5¼ 5 14 13¼ 14 8 6¼ ⁄16 1615⁄16 326JM 6 21 ⁄32 364TCZ 55⁄8 17¾ 151⁄8 15½ 9 7 1 19 365TCZ 61⁄8
364TCZ and 365TCZ frames are built with 326JM shaft extensions. Dimensions may vary with manufacturer. Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM. Las dimensiones puede que varíen con los fabricantes. PAGE 30
Motor Frame Selections, Selecciones del Armazón del Motor Motor Horsepower, Potencia del Motor Wt. 3500 RPM 1750 RPM Max., Frame, Armazón 3 PH, Trifásicos Peso 1 PH, Monofásicos 3 PH, Trifásicos Máx. ODP TEFC ODP TEFC ODP TEFC 145JM – – – – 2 2 57 182JM – – 2 2, 3 3 3 77 184JM – – 3 – 5 5 97 213JM 10 – 5 – 7½ 7½ 141 215JM 15 10 – – 10 10 155 254JM 20 15 – – 15 15 265 256JM 25 20 – – 20 20 320 284JM 30 25 – – 25 25 419 286JM 40 30 – – – – 422 324JM 50 40 – – – – 562 326JM 60 50 – – – – 625 364TCZ 75 60 – – – – 775 365TCZ 100 75, 100 – – – – 905 364TCZ and 365TCZ frames are built with 326JM shaft extensions. Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM.
Goulds Water Technology Commercial Water SSH FRAME MOUNTED – DIMENSIONS AND WEIGHTS SSH ARMAZÓN MONTADO – DIMENSIONES Y PESOS
DISCHARGE DESCARGA
S-GROUP GRUPO-S
CP Y
Z
PRIME PLUG X
3½
SUCTION SUCCIÓN
5¼
2¾
2¾
1.125 DIA. 1.124 KEYWAY 1⁄8 x ¼, CHAVETERO 1⁄8 x ¼ 7 ⁄16 DIA. – (4) HOLES 7 ⁄16 DIA. – (4) AGUJEROS
DC MAX. DD
DRAIN PLUG
7
L ⁄8" – 19 BSP
3
5
¾
½
6½
Dimensions and Weights – Bare Pump Only, Dimensiones y Pesos – Solamente Bomba 150 lb. Flange, Brida de 150 lib.
CP DC Pump, Max., DD Max., L X Y Z Bomba CP Suction*, Discharge*, DC Máx. Máx. Succión* Descarga*
Wt. (lbs.), Peso (libras)
9SH 1 x 2 – 6 5 4¾ 63⁄8 1 56 163⁄4 77⁄8 3 ⁄8 5 3 10SH 1 x 2 – 8 2 1 5 ⁄8 5 ⁄8 71⁄8 37⁄8 64 11SH 1 x 2 – 10 67⁄8 65⁄8 179⁄16 8¾ 87⁄8 4 86 4SH 1½ x 2½ – 6 5 4¾ 169⁄16 7¾ 63⁄8 3¼ 57 1½ 7SH 1½ x 2½ – 8 55⁄8 53⁄8 1 65 2½ 7 ⁄8 5SH 2 x 2½ – 6 5 4¾ 5 35⁄8 57 2 17 ⁄16 8½ 4 8SH 2 x 2½ – 8 15 68 6 5¾ 7 ⁄16 6SH 2½ x 3 – 6 3 2½ 59 * For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150.
NOTE: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 –16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs. 2. ALL dimensions in inches. 3. Not for construction purposes.
NOTA: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.
PAGE 31
Goulds Water Technology Commercial Water SSH FRAME MOUNTED – DIMENSIONS AND WEIGHTS SSH ARMAZÓN MONTADO – DIMENSIONES Y PESOS
M-GROUP GRUPO-M
CP DISCHARGE
4 /
Y
15 16
PRIME PLUG
37/8 SUCTION
1.625 1.624
31/2
31/2
DC
MAX.
DD
4 HOLES 9 / 1 6 D IA .
61/2
L
DRAIN PLUG
81/2
KEYWAY
/16 X 3/8
3
61/4
DIA.
1"
/
1 2
81/2
/8" – BSP
3
Dimensions and Weights – Bare Pump Only, Dimensiones y Pesos – Solamente Bomba Wt. DC Pump Size, Max., DD L X Y (lbs.), Suction*, Discharge*, Tamaño de Pump CP DC Peso Descarga* la Bomba Succión* Máx. (libras) 24SH 1½ x 2½-10 1½ 125 2½ 67⁄8 65⁄8 25SH 2 x 2½-10 2 815⁄16 125 23 10¼ 4 22SH 2½ x 3-8 61⁄8 57⁄8 125 3 2½ 27SH 2½ x 3-10 15 134 67⁄8 65⁄8 9 ⁄16 23SH 3 x 4-8 136 4 3 24 11¼ 5 28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148 * For use with ANSI class 150 mating flanges. * Para usar con bridas que casan ANSI clase 150. NOTES: 1. Pumps will be shipped with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 3⁄8 –16 bolts to 12 ft./lbs. 2. Motor dimensions may vary with motor manufacturer. 3. Not for construction purposes.
PAGE 32
NOTAS: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construcción.
Goulds Water Technology Commercial Water SPECIFICATIONS ESPECIFICACIONES Capacities to: 1100 GPM (250 m3/hr) at 3500 RPM 775 GPM (177 m3/hr) at 1750 RPM Heads to: 525 feet THD (158 m) at 3500 RPM 130 feet THD (40 m) at 1750 RPM Maximum working pressures to: 230 PSI (15 bars) Maximum temperatures to: 250°F (121°C) All wetted components of AISI: Type 316L stainless steel material. Rotation: Clockwise when viewed from motor end. Enclosed impeller and replaceable wear ring: for high efficiency and maximum wear life. Motor (close coupled): NEMA standard JM shaft open drip-proof, totally enclosed and explosion-proof enclosures, 60 Hz, 1750 or 3500 RPM. Single phase ODP (115/230 V) 1750 RPM, 1 – 5 HP. Three phase ODP. TEFC/Exp. proof (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP
NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Motor (frame mounted): NEMA standard T-frame open drip-proof, totally enclosed and explosionproof (three phase only) enclosures 60 Hz, 1750 or 3500 RPM. Single phase (115/230 V) 1750 RPM, 1 – 5 HP Three phase (208 – 230/ 460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP NOTE: Overload protection must be provided. Contactor with overload for single phase or starter with heaters for three phase ordered separately. Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings.
Capacidades: 1100 GPM (105 m 3/hr) a 3500 RPM 775 GPM (177 m3/hr) a 1750 RPM Cargas: 525 pies THD (158 m) a 3500 RPM 130 pies THD (40 m) a 1750 RPM Presión de trabajo máxima: 230 PSI (15 baras) Temperatura máxima: 250°F (121°C) Todos los componentes mojados de AISI: Material de acero inoxidable tipo 316L. Rotación: En dirección de las agujas del reloj visto desde el extremo final del motor. Impulsor encerrado y anillo de desgaste reemplazable: para alta eficiencia y máxima durabilidad. Motor (acople cerrado): Eje a prueba de goteo JM estándar NEMA, totalmente encerrado y recintos a prueba de explosión, 60 Hz, 1750 ó 3500 RPM. Unifásicos ODP (115/230 V) 1750 RPM, 1 – 5 HP Trifásicos ODP. TEFC/a prueba de explosión (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP
NOTA: Se debe de proporcionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado. Motor (armazón montado): Armazón abierto T a prueba de goteo estándar NEMA, totalmente encerrado y recintos a prueba de explosión (trifásicos solamente) 60 Hz, 1750 ó 3500 RPM. Unifásicos (115/230 V) 1750 RPM, 1 – 5 HP. Trifásicos (208 – 230/460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP NOTA: Se debe de proporcionar protección térmica contra sobrecarga. Contactor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por separado. Opcional: Fundación rígida de acero al carbono, guarda acople de metal laminado diseñado según las especificaciones OSHA y acoples del espaciador T.B. WOODS tipo “SC”.
PAGE 33
Goulds Water Technology Commercial Water TYPICAL APPLICATIONS APLICACIONES TÍPICAS HVAC, Calefacción, Ventilación y Aire Acondicionado
Water truck, Camión cisterna
PAGE 34
Specifically designed for all traditional cast iron or bronze fitted water and low grade corrosive services.
Diseñada específicamente para todos los servicios de agua de hierro fundido o recubiertas de bronce y servicios corrosivos de bajo grado.
• Water circulation
• Circulación de Agua
• Booster systems
• Aumento de presión
• Liquid transfer
• Transferencia de líquidos
• HVAC pump replacements
• Reemplazos para bombas HVAC
• General service pumping
• Bombeo de servicios generales
PCB washer, Arandela PCB
Tubing washer, Arandela de tubería
Textile dyes, Colorantes textiles
Reverse osmosis, Ósmosis invertida
Boiler feed, Alimentación de caldera
Goulds Water Technology Commercial Water NOTES NOTAS
PAGE 35
Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We’re a global team unified in a common purpose: creating innovative solutions to meet our world’s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com
Xylem 1) El tejido en las plantas que hace que el agua suba desde las raíces; 2) una compañía líder global en tecnología en agua. Somos un equipo global unido por un propósito común: crear soluciones innovadoras para satisfacer las necesidades de agua de nuestro mundo. Desarrollar nuevas tecnologías que mejorarán la manera en que se usa, se conserva y se reutiliza el agua en el futuro es un aspecto crucial de nuestra labor. Transportamos, tratamos, analizamos y retornamos el agua al medio ambiente, y ayudamos a las personas a usar el agua de manera eficiente, en sus casas, edificios, fábricas y campos. Desde hace mucho tiempo y en más de 150 países, tenemos relaciones sólidas con clientes que nos conocen por nuestra potente combinación de marcas de producto líderes y conocimientos de aplicación, con el respaldo de nuestro legado de innovación. Para obtener más información, visite xyleminc.com.
Xylem Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148 Phone/Teléfono: (800) 453-6777 Fax: (888) 322-5877 www.gouldswatertechnology.com Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. Goulds es una marca registrada de Goulds Pumps, Inc. utilizada con permiso. © 2015 Xylem Inc.
BSSH R1
July (Julio) 2015