technical brochure

3⁄4-5 HP. 3500 RPM. 2SL. U.S. GPM m3/hr. NOTES: 1. Not recommended for operation ...... Goulds is a registered trademark of Goulds Pumps, Inc. and is.
775KB Größe 18 Downloads 65 vistas
TECHNICAL BROCHURE BNPV R2

NPV VERTICALLY IMMERSED ALL STAINLESS STEEL END SUCTION PUMPS BOMBAS NPV DE ASPIRACIÓN AXIAL, TODAS DE ACERO INOXIDABLE, SUMERGIDAS VERTICALMENTE

Goulds Water Technology Commercial Water A FULL RANGE OF NPV PRODUCT FEATURES UNA GAMA TOTAL DE CARACTERÍSTICAS DEL PRODUCTO NPV Superior Materials of Construction: Complete AISI 300 series stainless steel liquid handling components for corrosion resistance, quality appearance and improved strength.

Materiales Superiores de Construcción: Componentes completos para manejo de líquidos en acero inoxidable 300 AISI, resistencia a la corrosión, apariencia de calidad, y resistencia mejoradas.

High Efficiency Impeller: Enclosed impeller with unique floating O-ring design maintains maximum efficiencies over the life of the pump without adjustment.

Impulsor de Alta Eficiencia: El impulsor encerrado con un diseño único de anillo en O flotante, mantiene sin ajustes, la eficiencia máxima durante la vida de la bomba.

Casing Features: Stainless steel construction with NPT threaded, centerline connections. Motors: NEMA standard open drip- proof, totally enclosed fan cooled or explosion proof enclosures. Rugged ball bearing design for continuous duty under all operating conditions.

SL

SR

PAGE 2

Características de la Carcasa: Construcción de acero inoxidable con rosca NPT, conexiones centrales. Motores: Estándar NEMA en cubiertas abiertas a prueba de goteo, totalmente cerradas y enfriadas con ventilador, o en cubiertas a prueba de explosión. Diseño robusto de cojinetes de bolas para trabajo continuo en todas las condiciones de funcionamiento.

The various versions of the NPV are identified by a product code number on the pump label. This number is also the catalog number for the pump. The meaning of each digit in the product code number is shown at left. Las diferentes versiones de la NPV se identifican con un número de código del producto en la etiqueta de la bomba. Este número es también el número del catálogo para la bomba. El significado de cada dígito en el número de código del producto se muestra a la izquierda.

NPV PRODUCT LINE NUMBERING SYSTEM LÍNEA DE PRODUCTO NPV SISTEMA DE NUMERACIÓN Example Product Code, Ejemplo Código del Producto 1 SL 2 C 01 A 1 H

Optional: Hardened Shaft (Ceramic) Shaft, Bearing and Elastomer Options Standard is Option 1 Opciones de eje, cojinete y elastómero Opción 1 es estándar Materials, Materiales Option, Shaft, Bearing, O-rings, Opción Eje Cojinete Anillos en O 1 14" Viton, Viton Viton, Viton 2 14" Carb. graph., Graf. de Carb. Viton, Viton 3 14" EPR EPR 4 14" Carb. graph., Graf. de Carb. EPR 5 24" Viton, Viton Viton, Viton 6 24" Carb. graph., Graf. de Carb. Viton, Viton 7 24" EPR EPR 8 24" Carb. graph., Graf. de Carb. EPR

Impeller Option Code... No Adder Required For optional impeller diameters modify catalog order no. with impeller code listed. Select optional impeller diameter from pump performance curve. Código del Impulsor Opcional... No necesita sumador Para impulsores con diámetros opcionales modificar el número de orden del catálogo con el código del impulser anotado. Escoger el impulsor con diámetro opcional de la curva de rendimiento de la bomba. Pump Size, Tamãno de la Bomba Impeller Code, 1 x 1¼ ­– 6 1¼ x 1½ – 6 1½ x 2 – 6 Código del Impulsor Impeller Diameter (in.) 1SL 1SR 2SL 2SR 3SL 3SR

A B C D E F G H K

61⁄8 45⁄16 5¼ 55⁄16 4¾ 57⁄16 5¾ 4 51⁄16 51⁄16 45⁄8 5¼ 53⁄16 3¾ 47⁄8 45⁄8 43⁄8 415⁄16 4¾ 3½ 45⁄8 45⁄16 41⁄16 45⁄8 47⁄16 3¼ 4¼ 41⁄16 35⁄8 47⁄16 41⁄16 3 37⁄8 3¾ – 43⁄16 – 53⁄8 515⁄16 37⁄16 53⁄8 3¾ – 5 5½ – 5 – – – 61⁄8 – – –

Driver, Conductor 01 = 1 PH, ODP 07 = 3 PH, XP 02 = 3 PH, ODP 08 = 575 V, XP 03 = 575 V, ODP 09 = 3 PH TEPE, 04 = 1 PH, TEFC Premium Efficiency 05 = 3 PH, TEFC 10 = 1 PH, XP 06 = 575 V, TEFC HP Rating, Potencia en HP C = ½ HP E = 1 HP G = 2 HP J = 5 HP D = ¾ HP F = 1½ HP H = 3 HP Driver: Hertz/Pole/RPM, Condutor: Hercois/Polos/RPM 1 = 60 Hz, 2 pole, 3500 RPM 2 = 60 Hz, 4 pole, 1750 RPM 3 = 60 Hz, 6 pole, 1150 RPM 4 = 50 Hz, 2 pole, 2900 RPM 5 = 50 Hz, 4 pole, 1450 RPM Material, Material SL = Stainless Steel Closed Impeller SR = Stainless Steel Open Impeller SL = Impulsor cerrado, de acero inoxidable SR = Impulsor abierto, de acero inoxidable Pump Size, Tamãno de la Bomba 1 = 1 x 1¼ – 6 3 = 1½ x 2 – 6 2 = 1¼ x 1½ – 6

Goulds Water Technology Commercial Water NPV PERFORMANCE COVERAGE (60 HZ) COBERTURA DE RENDIMIENTO NPV (60 HZ) METERS FEET METROS PIES

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

50

160

140 40 120

30

100

1 x 11⁄4 - 6 1 ⁄2 - 2 HP 3500 RPM 1SL

80 20

11⁄4 x 11⁄2 - 6 3 ⁄4 - 5 HP 3500 RPM 2SL

60

40 10

1SL 1750 RPM

20

0

0

0

2SL 1750 RPM

3SL 1750 RPM

40

20

0

5

60 10

80 15

100 20

120

25

140

25

30

160

U.S. GPM

m3/hr

35

MODEL NPV “SR” PERFORMANCE COVERAGE COBERTURA DE RENDIMIENTO DEL MODELO NPV “SR”

35

30

120

CAPACITY (CAPACIDAD) (Q)

METERS FEET

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

11⁄2 x 2 - 6 1- 5 HP 3500 RPM 3SL

100

80

20 60

15 40

3SR 3500 RPM

1SR 3500 RPM

10

2SR 3500 RPM

20 5

0

1SR 1750 RPM 0

0

0

50

25 5

3SR 1750 RPM

2SR 1750 RPM

10

100

75 15

20

125 25

150 30

35

175 40

200 45

250 U.S. GPM

225 50

55

m3/hr

CAPACITY (CAPACIDAD) (Q)

NOTES: 1. Not recommended for operation beyond printed H-Q curve.

NOTAS: 1. No se recomienda para funcionamiento superior al impreso en la curva H-Q.

2. For critical application conditions consult factory.

2. Para condiciones de aplicaciones críticas consultar con la fábrica.

3. Not all combinations of motor and impeller options are available for every pump model. Please check with G&L on non-cataloged numbers.

3. No todas las combinaciones de las opciones de motor e impulsor están disponibles para cada modelo de bomba. Por favor verifique con G&L los números no catalogados. PAGE 3

Goulds Water Technology Commercial Water

NPV SL/SR MAJOR COMPONENTS: MATERIALS OF CONSTRUCTION COMPONENTES PRINCIPALES NPV SL/SR: MATERIALES DE CONSTRUCCIÓN

23 10 9

8

12 12A

11

13 15A 15B 15C 17

14

16

6

7

5 4

DISCHARGE DESCARGA SUCCIÓN 2

SR

PAGE 4

DISCHARGE DESCARGA 22 (1SR ONLY) (1SR SOLAMENTE) 3

18 19

1

21

SUCTION 20 SUCCIÓN

SL

Goulds Water Technology Commercial Water

Item No., Qty. Description, Parte No. Cant. Descripción

Materials, Materiales

Casing, Pump SL; 1 1 Carcasa, bomba SL AISI 316 SS, Casing, Pump SR; AISI Acero 2 1 Carcasa, bomba SR inoxidable 316 3 1 Guidevane, Aleta guiadora



4 1 O-ring, Casing; Anillo en 0, carcasa

Viton/EPR, Viton/EPR

¼-20 NC-2A x .50 long socket head cap screw, 5 8 Tornillo de casquete de cabeza AISI 304 SS, hueca de ¼-20 NC-2A x, AISI Acero 0,50 de largo inoxidable 304 8 ¼-20 NC hex nut, 6 Tuerca hexagonal de ¼-20 NC Pump mounting plate, 7 1 Placa de montaje de la bomba

AISI 303 SS, AISI Acero inoxidable 303

3 ⁄8-16 NC-2A x 1.0 long 8 4 Plated steel, hex head bolt, Acero enchapado Perno de cabeza hexagonal de 3 ⁄8-15 NC-2A x 1,0 de largo

Motor mounting plate, 9 1 Placa de montaje del motor 10

1 Motor, Motor



11

1

Tube, support; Tubo, apoyo



12

1

Shaft, Eje

1

Shaft, Ceramic Coated, Eje

12A

Nitronic 60 stainless, Nitronic 60, inoxidable

15B 1 Bearing, Cojinete 15C

1

Bearing, Cojinete

AISI 316 SS, AISI Acero inoxidable 316

17 1

Impeller (closed), AISI 316 SS, Impulsor (cerrado) AISI Acero Plug, drain and vent; inoxidable 316 18 2 Tapón, drenaje y ventilación O-ring, drain and vent plug; Viton/EPR 19 2 Anillo en 0, tapón de drenaje Viton/EPR y ventilación 20 1 Nut, impeller Tuerca, impulsor

300 Series SS, Serie 300, AI

O-ring, impeller; 21 1 Viton, Viton Anillo en 0, impulsor 22* 1 O-ring, internal casing; Viton, Viton Anillo en 0, carcasa interna

23

1

Seal, U-cup; Sello, taza en U

Teflon, Teflón

* Not required on 2SL & 3SL.

AISI 304 SS, AISI Acero inoxidable 304

14 1 Bushing, Casquillo Bearing, Cojinete

Impeller (open), 16 1 Impulsor (abierto)

Electrical, Eléctrico

Stainless steel, Acero inoxidable

1

Materials, Materiales

Cast iron, Hierro fundido

13 1 Snap ring, Anillo de resorte

15A

Item No., Qty. Description, Parte No. Cant. Descripción

Viton, Viton Carbon graphite, Grafito de carbono EPR

PAGE 5

Goulds Water Technology Commercial Water NPV PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM

METERS FEET METROS PIES

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

Impeller Selections for ODP Motors Selecciones del Impulsor para Motores abiertos a prueba de goteo

Model NPV / 1SL Size (Tamaño) 1 x 11/4 - 6 RPM 3500 Curve (Curva) CN0380R00

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Ordering Code, Código de Pedido

Imp. Dia.



F

41⁄16" Spec.



E

47⁄16"

D 180 50

C 53⁄16

NPSHR – FEET (PIES) 160

A 61/8" DIA.

140

40

B 53/4"

40

5' 43

6' 45

120 30

80 20

10

48

D 43/4"

10' 12' 46 45 43 EFF %

47

B

53⁄4



A 61⁄8

2H P

60

1H P

40

0



E 47/16"

1

/2 H

20 0

8'

46

C 53/16" 100

43⁄4

3

/4

P

0

10

20

0

30

1 1/

2

HP

HP

40

50

5

60

70

10

80 U.S. GPM m3/hr

15

CAPACITY (CAPACIDAD) (Q)

METERS FEET METROS PIES

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

50

40

30

NPSHR – FEET (PIES) 5' 130 K 6 /8" DIA. 45 15 50 120 G 5 /16"

7'

1

110 100

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 2SL Size (Tamaño) 11/4 x 11/2 - 6 RPM 3500 Curve (Curva) CN0235R05

10'

53

H 51/2" 55

1

B 5 /16"

53

57

90 25

50 EFF %

C 47/8" 80

59

5

61

D 45/8"

HP

70 20 60 15

50

5

3 F 37/8"

2 11 /2

3

/4

20

0

20 5

HP

40

1 60

10

HP

HP

HP

80 15

HP

100 20

120 25

CAPACITY (CAPACIDAD) (Q)

PAGE 6

F

37⁄8"

E

41⁄4



C

47⁄8



B

51⁄16



A 51⁄4



G



H 51⁄2



K 61⁄8

E 4 /4"

30

10 0



1

40 10

Imp. Dia.

D 45⁄8

15' 20'

A 51/4"

Ordering Code, Código de Pedido

140 30

160 U.S. GPM 35

m3/hr

515⁄16

Goulds Water Technology Commercial Water NPV PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM

METERS FEET METROS PIES

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

35

30

Model NPV / 3SL Size (Tamaño) 11/2 x 2 - 6 RPM 3500 Curve (Curva) CN0386R00

120

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

NPSHR – FEET (PIES) 48

3

100 G 5 /8" DIA.

25

Impeller Selections for ODP Motors Selecciones del Impulsor para Motores abiertos a prueba de goteo

5' 53

6'

58

62 7'

20

64

10'



E

35⁄8"

D

41⁄16

5

B 45⁄8

17'

HP

64 EFF%

3

A 4 /4"



A

43⁄4

H 5

B 45/8"

62

3 60 C 4 /8"

15

Imp. Dia.

C 43⁄8

H 5" 80

Ordering Code, Código de Pedido



G

53⁄8

D 41/16" 58

5 40 E 3 /8"

10

3H

P

5

1H

20

P 1 1/

2

0

0

0 0

20 5

40

60 10

80 15

100 20

53 2H

P

HP

120 25

140 30

160 U.S. GPM 35

m3/hr

CAPACITY (CAPACIDAD) (Q)

PAGE 7

Goulds Water Technology Commercial Water NPV PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

METERS FEET METROS PIES

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 1SL Size (Tamaño) 1 x 11/4 - 6 RPM 1750 Curve (Curva) CN0382R00

Optional Impeller, Impulsor Opcional Ordering Code, Código de Pedido

14

12

A 61/8" DIA.

40 5' 43

B 53/4" 30

4

C

NPSHR – FEET (PIES)

40

10

6

61⁄8"

B 53⁄4

45

35

8

A

Dia.

8'

45 46

46

D 43/4"

20

D 43⁄4

6'

C 53/16"

25

47

48

10' 12' 45

43 EFF %



E 47⁄16



F 41⁄16

1

/3 H

P

7

E 4 /16" 15

53⁄16

F 41/16"

10 2

0

8' 9'

12' NPSHR – FEET (PIES)

5 0

0

5

0

1

10

15

2

3

20 4

25

30

5

6

40 U.S. GPM

35

7

8

m3/hr

9

CAPACITY (CAPACIDAD) (Q)

METERS FEET METROS PIES

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

10

9

32.5 30 27.5

8 25 7

6

22.5

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 2SL Size (Tamaño) 11/4 x 11/2 - 6 RPM 1750 Curve (Curva) CN0238R01 1

K 6 /8" DIA.

NPSHR – FEET (PIES) 5'

G 515/16"

45

53

H 51/2"

15' 20'

57

C

50 EFF %

E 41⁄4



F 37⁄8



G 515⁄16



H 51⁄2



K 61⁄8

5

4

3

2

3

/4

E 41/4"

1

/2

7 10 F 3 /8"

0

HP

1

/3

7.5

0

10 2

20 4

30 6

40 8

50 10

60 12

CAPACITY (CAPACIDAD) (Q)

PAGE 8

HP

12.5

5

47⁄8



61

17.5 D 45/8" 15

51⁄4"

D 45⁄8

53

59

20 C 47/8"

A

Dia.

B 51⁄16

10' 55

A 51/4" B 51/16"

Ordering Code, Código de Pedido

7' 50

Optional Impeller, Impulsor Opcional

14

HP 70 16

80 U.S. GPM 18

m3/hr

Goulds Water Technology Commercial Water NPV PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

METERS FEET METROS PIES

5' 53

48

8

62 7'

6'

10' 64

7

H 5"

3

62

C4 /" 38

D 41/16"

4

1 /2 H P 58

E 35/8"

10

Dia.

43⁄4"

43⁄8

D 41⁄16

64

B 45/8" 15

A

C

17'

20 A 43/4"

5

Ordering Code, Código de Pedido

B 45⁄8 58

G 53/8" DIA.

25

Optional Impeller, Impulsor Opcional



NPSHR – FEET (PIES)

30

6

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 3SL Size (Tamaño) 11/2 x 2 - 6 RPM 1750 Curve (Curva) CN0388R00



E 35⁄8



H

5

G 53⁄8

1

/3 H

P 53 EFF %

2 5 1 0

0

10

0

2

0

30

20 4

50

40

6

8

10

60 12

14

80 U.S. GPM

70 16

18

m3/hr

CAPACITY (CAPACIDAD) (Q)

NPV PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

METERS FEET METROS PIES

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

(Tamaño) 1 x 11/4 - 6

Model NPV / 1SL Size RPM 2900 50 Hz

Optional Impeller, Impulsor Opcional Ordering Code, Código de Pedido

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

50



140

120

NPSHR – FEET (PIES)

1 100 A 6 /8" DIA.

EFF %

B 53/4"

C

40

C 53/16"

43 45

6' 46

48 47

60 D 43/4"

8' 10' 45 43

11 /2

40 F 41/16"

0

0

1

8'

20

9'

3

/4 H

12'



E 47⁄16



F 41⁄16

12'

46

E 47/16" 10

53⁄16

D 43⁄4

5'

80 20

61⁄8"

B 53⁄4

40

30

A

Dia.

HP

HP

P

1

/2 H

P

0 0

10

20

30 5

40

50 10

CAPACITY (CAPACIDAD) (Q)

60

U.S. GPM 15

m3/hr

PAGE 9

Goulds Water Technology Commercial Water NPV PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

25

K 61/8" DIA.

80

5' 50

45

G 515/16"

7' NPSHR – FEET (PIES) 53 10'

H 51/2"

15' 20'

A 51/4" 70

55

1

B 5 /16"

20

60 C 4 /8"

EFF %

59

D 4 /8"

3

50

2

10

F 37/8"

1

30 1

5

0

/2

20

10 7 0

20

0

40

5

60 10

HP

HP

HP

80 15

Dia.



51⁄4"

A

100 20

47⁄8

D 45⁄8

HP

E 41/4" 40

Ordering Code, Código de Pedido

C

50

61

5

Optional Impeller, Impulsor Opcional

B 51⁄16

53 57

7

15

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 2SL Size (Tamaño) 11/4 x 11/2 - 6 RPM 2900 Curve 50 Hz

METERS FEET METROS PIES 90

120 25



E 41⁄4



F 37⁄8



G 515⁄16



H 51⁄2



K 61⁄8

U.S. GPM 30

m3/hr

CAPACITY (CAPACIDAD) (Q)

Model NPV / 3SL Size RPM 2900 50 Hz

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

METERS FEET METROS PIES

25

(Tamaño) 11/2 x 2 - 6

NPSHR – FEET (PIES) 48 5' 53

70 G 53/8" DIA.

58 6'

62 7'

64

3

A 43/4"

17'

HP

64 EFF%

10

62

D 41/16"



2H P 53 1H P /2 H P

5

1

10

0 0

20 5

40

60 10

80 15

100 20

CAPACITY (CAPACIDAD) (Q)

PAGE 10

43⁄8

E 35⁄8

H 5 58

5 30 E 3 /8"

0

C



20

0

43⁄4"

D 41⁄16

C 43/8" 40

A

Dia.

B 45⁄8

10'

50 B 45/8" 15

Ordering Code, Código de Pedido

60 H 5" 20

Optional Impeller, Impulsor Opcional

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

U.S. GPM

120 25

30

m3/hr

G 53⁄8

Goulds Water Technology Commercial Water SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTO NPV PERFORMANCE CURVES – 60 HZ, 3500 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

METERS FEET METROS PIES

90 25

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 1SR Size (Tamaño) 1 x 11/4 - 6 RPM 3500 Curve (Curva) CN0415R00 NPSHR – FEET (PIES) 6' EFF % 20 25

G 53/8" DIA.

12'

70 5

A 4 /16"

30

D 31⁄2

25

B 4" 50

E 31⁄4

3

C 3 /4"

F

40 D 31/2" 10

3

20 5

32 10 0

32

0

3

G 53⁄8

1 30 E 3 /4"

F 3"

0

4

C 33⁄4

18'

60 15

Dia.

B

10'

30

20

Ordering Code, Código de Pedido

A 45⁄16"

8'

H 5"

80

Optional Impeller, Impulsor Opcional

10

20

0

30

1

/2

40

5

3

/4

HP

50

11 /2

1

HP HP

60

2

H

5

HP

HP 90 U.S. GPM

80

70

10

HP

15

20

m3/hr

CAPACITY (CAPACIDAD) (Q)

METERS FEET METROS PIES

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 2SR Size (Tamaño) 11/4 x 11/2 - 6 RPM 3500 Curve (Curva) CN0543R00

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

35

30

30 EFF %

3' NPSHR – FEET (PIES)

42

20

C 45⁄8

6'

40

C 45/8"

D 45⁄16

9'

60 D 45/16"

E 41⁄16

12'

E 41/16"

44

42

10

5

F 3 /4"

40

G 37⁄16

G 37/16"

20

3

0

F 33⁄4

15'

3

40

Dia.

B 51⁄16

80

15

Ordering Code, Código de Pedido

A 55⁄16"

100 A 55/16" DIA.

B 51/16" 25

Optional Impeller, Impulsor Opcional

/4

0 0

20

0

5

40 10

60 15

P

100

80 20

11 /2

1H

HP

HP

120 25

3H P

2H P

140 30

160 U.S. GPM 35

m3/hr 40

CAPACITY (CAPACIDAD) (Q)

PAGE 11

Goulds Water Technology Commercial Water SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTO NPV PERFORMANCE CURVES – 60 HZ, 3500 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 3SR Size (Tamaño) 11/2 x 2 - 6 RPM 3500 Curve (Curva) CN0546R00

METERS FEET METROS PIES 120

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

35

30

Ordering Code, Código de Pedido

7

A 5 /16" DIA.

B 51⁄4

50

C 415⁄16

80 D 45/8"

20'

E 47/16"

25'

D 45⁄8

52

F 43/16"

20

Dia.

A 57⁄16"

5' NPSHR – FEET (PIES) 40 EFF % 15' 45 10'

B 51/4"

100

C 415/16" 25

Optional Impeller, Impulsor Opcional

30'

45

E 47⁄16

60

G 33/4"

35' 71 /2

15 40

F 43⁄16

HP

G 33⁄4

10

5H P 5

20

3 2

0

0

0

50

0

5

100

10

15

20

HP

150 25

30

HP

35

200 40

U.S. GPM 50 m3/hr 55

45

CAPACITY (CAPACIDAD) (Q)

SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTO NPV PERFORMANCE CURVES – 60 HZ, 1750 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

METERS FEET METROS PIES 25

20

Model NPV / 1SR Size (Tamaño) 1 x 11/4 - 6 RPM 1750 Curve (Curva) CN0549R00 EFF% 20

G 5 3/

3' NPSHR – FEET (PIES)

IA.

30

10'

DIA.

E 31⁄4

IA.

F

DIA.

D 31/2 " DIA.

2.5

E 31/4"

5

IA.

/2 H

P

32 32

0

0

0 0

5

10

15

20

25 5

CAPACITY (CAPACIDAD) (Q)

PAGE 12

30

35

3

G 53⁄8

1

DIA.

F 3" D

4

D 31⁄2

25

B 4" D 10

Dia.

C 33⁄4

6'

5

C 33/4"

Ordering Code, Código de Pedido

B

30

DIA.

15 A 45 /16"

Optional Impeller, Impulsor Opcional

A 45⁄16"

25

8" D

H 5"

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

40 U.S. GPM 45 10 m3/hr

H

5

Goulds Water Technology Commercial Water SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTO NPV PERFORMANCE CURVES – 60 HZ, 1750 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

METERS FEET METROS PIES 30 9

25

A 55/16" DIA. 30 EFF %

B 51/16" 20

C 45/8" 5 15 4

3

Ordering Code, Código de Pedido

Dia.

B 51⁄16

7

6

Optional Impeller, Impulsor Opcional

A 55⁄16"

8

C 45⁄8 2' NPSHR – FEET (PIES) 38 40

D 45⁄16

3'

E 41⁄16

5

D 4 /16"

42

4'

E 41/16"

F 33⁄4

40 38 5'

3 10 F 3 /4"

G 37⁄16

G 37/16"

1

/2 H

2

P

5 1

0

0

0

20

10

0

METERS FEET METROS PIES 9

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 2SR Size (Tamaño) 11/4 x 11/2 - 6 RPM 1750 Curve (Curva) CN0544R00

5

10 CAPACITY (CAPACIDAD) (Q)

Model NPV / 3SR Size (Tamaño) 11/2 x 2 - 6 RPM 1750 Curve (Curva) CN0547R00

80 U.S. GPM

70

m3/hr

15

20

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

A 57/16" DIA. 25

3' NPSHR – FEET (PIES)

C 4 /16"

5 15 4

Ordering Code, Código de Pedido

Dia.

B 51⁄4

43 EFF % 48

15

20

Optional Impeller, Impulsor Opcional

A 57⁄16"

B 51/4"

7

3

60

50

30

8

6

40

30

C 415⁄16

5

D 4 /8" E 47/16"

48 6'

50

F 43/16"

D 45⁄8 43

E 47⁄16 9'

G 33/4"

F 43⁄16 G 33⁄4

10 3

/4

2 1

/2 H

5

HP

P

1

0

0

0 0

20 5

40

80

60 10

15

100 20

120 25

U.S. GPM 30 m3/hr

CAPACITY (CAPACIDAD) (Q)

PAGE 13

Goulds Water Technology Commercial Water SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTO NPV PERFORMANCE CURVES – 50 HZ, 2900 RPM, CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

METERS FEET METROS PIES

70 20

G 53/8" DIA. 60 H 5"

15

Ordering Code, Código de Pedido

B 30

9'

30

B 4"

12' 25

D 31⁄2

18'

E 31⁄4

D 31/2"

F

30 E 31/4"

F 3"

2

20 5

32

10

3

/4

1

/2

32 0

0

0

10

5

0

4

C 33⁄4

10'

40 C 33/4" 10

Dia.

A 45⁄16"

NPSHR – FEET (PIES) 6' EFF % 20 25

A 45/16"

50

Optional Impeller, Impulsor Opcional

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 1SR Size (Tamaño) 1 x 11/4 - 6 RPM 2900 Curve (Curva) CN0416R00

15

20

25

30

35

40

50

45

2

12

11 /2

G 53⁄8 HP

H

5

HP

HP

60

55

10

HP 1 H P

3

65

14

75 U.S. GPM

70 16

m3/hr

CAPACITY (CAPACIDAD) (Q)

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

METERS FEET METROS PIES 80

70 20 60

15

Model NPV / 2SR Size (Tamaño) 11/4 x 11/2 - 6 RPM 2900 Curve (Curva) CN0545R00

40

5 50 C 4 /8"

4' 42

D 45⁄16 E 41⁄16

6' 44

8'

F 33⁄4

42 40 10'

3 30 F 3 /4"

G 37⁄16

G 3 /16"

2H P

20 5 10

1 1/

2

1H P 1 /2 H /4 HP P 3

0 0

20 5

40

80

60 10

15

120

100 20

CAPACITY (CAPACIDAD) (Q)

PAGE 14

Dia.

C 45⁄8

E 41/16"

0

Ordering Code, Código de Pedido

B 51⁄16

30 EFF % 2' NPSHR – FEET (PIES)

B 51/16"

7

0

Optional Impeller, Impulsor Opcional

A 55⁄16"

A 55/16" DIA.

5 40 D 4 /16"

10

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

25

HP

U.S. GPM 30 m3/hr

Goulds Water Technology Commercial Water SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTO NPV PERFORMANCE CURVES – 50 HZ, 2900 RPM, CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

METERS FEET METROS PIES 80

NOTE: Not recommended for operation beyond printed H-Q curve. NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

Model NPV / 3SR Size (Tamaño) 11/2 x 2 - 6 RPM 2900 Curve (Curva) CN0548R00

TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) (H)

A 57/16" DIA. 70 B 51/4" 20 60

15

C 415/16"

Dia.

B 51⁄4 C 415⁄16

D 45/8" 7 50 E 4 /16"

40

Ordering Code, Código de Pedido

A 57⁄16"

4' NPSHR – FEET (PIES) 40 EFF % 10' 45 50 14'

D 45⁄8

50

52

F 43/16"

Optional Impeller, Impulsor Opcional

17'

45

20'

G 33/4"

E 47⁄16 24'

F 43⁄16

10 30

G 33⁄4

5H

P

20 5

2 10

0

0

1

0 0

10

HP

100

50 5

11 /2

15

20

3H

P

HP

HP

150 25

30

35

200 40

45

U.S. GPM 50 m3/hr 55

CAPACITY (CAPACIDAD) (Q)

PAGE 15

Goulds Water Technology Commercial Water NPV PUMP – DIMENSIONS, WEIGHTS AND SPECIFICATIONS BOMBA NPV – DIMENSIONES, PESOS Y ESPECIFICACIONES 7,00 DIAM. 6,50 DIAM. MÁX. 7.00 DIA. 6.50 DIA. MAX.

OPTIONAL MOUNTING ACCESSORIES ACCESORIOS DE MONTAJE OPCIONALES MP1 .56 DIA. TYPICAL ,56 DIAM., TÍPICO

6.25

9.5 REF. 9,5 REF.

5 ⁄8" DIA. ⁄8" DIAM.

5

5.25

.50

C MAX. C MÁX.

15.50

14.0 REF. 14,0 REF.

11.00

1.50 REF.

B

B A

VIEW “A-A” .75 MOUNTING PLATE TYPICAL VISTA A-A ,75 TÍPICO PLACA DE MONTAJE

CLEARANCE HOLE AGUJERO DE PASO

“Y”

“X” 8.68

SUCTION SUCCIÓN

.56 DIA. TYPICAL ,56 DIAM., TÍPICO

MC1 5.97

5.97

6.0" MINIMUM LIQUID LEVEL 6,0" MÍNIMO NIVEL DEL LÍQUIDO

DISCHARGE DESCARGA

“N”

“R”

“M”

A

VIEW “B-B” MOUNTING CLAMP VISTA B-B ABRAZADERA DE MONTAJE

Dimensions – Determined by Pump, Dimensiones – Determinadas por la Bomba Dimensions Determined by Shaft, Dimensiones Determinadas por el Eje Max. Wt. Pump, Suction NPT, Discharge NPT, Pump only, M N R “X” “Y” Bomba Succión NPT Descarga NPT Peso máx., 14" 24" 14" 24" 14" 24" Bomba sola. 1SL/1SR 2SL/SR 3SL/SR

11⁄4 1 43⁄8 2 7.78 17.78 13.20 23.20 14.68 24.68 65 1 1 ⁄2 11⁄4 41⁄2 21⁄8 7.78 17.78 13.20 23.20 14.68 24.68 70 2 11⁄2 45⁄8 21⁄8 7.78 17.78 13.20 23.20 14.68 24.68 70

NOTES:

NOTAS:

1. Motor dimensions may vary with motor manufacturers.

1. Las dimensiones del motor puede que varíen con los fabricantes.

2. Dimensions in inches, weights in pounds.

2. Dimensiones en pulgadas, pesos en libras.

3. For explosion proof motor dimensions consult factory for information. 4. Not to be used for construction purposes unless certified. PAGE 16

3. Para las dimensiones de los motores a prueba de explosión consultar con la fábrica para información. 4. No usar para propósitos de construcción sin certificar.

Available Motor Weights and Dimensions, Pesos y Dimensiones de Motores que se ofrecen Motor Weights, Pesos del Motor C Max. Length, 3 Phase, Trifásicos 1 Phase, Monofásicos (Longitud) ODP TEFC EXP ODP TEFC EXP 1 ⁄2 16 21 47 19 18 27 103⁄16 3 ⁄4 19 24 41 21 21 30 107⁄16 1 22 26 49 23 21 30 111⁄16 11⁄2 28 35 56 27 27 37 1115⁄16 2 33 39 60 32 33 44 1211⁄16 3 40 43 — 41 37 — 139⁄16 5 50 — — 50 — — 139⁄16 71⁄2 — — — 49 — — 14 HP

Dimensions in inches, weights in pounds., Dimensiones en pulgadas, pesos en libras.

Goulds Water Technology Commercial Water NPV TYPICAL APPLICATIONS APLICACIONES TÍPICAS NPV Specifically designed for Tank Mounted applications traditionally requiring various materials such as all iron, bronze fitted or all bronze construction.

Diseñadas específicamente para aplicaciones de tanques montados, requiriendo tradicionalmente varios materiales, tales como todo de hierro, accesorios de bronce o toda la construcción de bronce.

• Machine coolant recirculation

• Recirculación del refrigerante de la máquina

• Part washer

• Lavador de pieza

• Liquid transfer

• Transferencia de líquidos

• Spray system

• Sistemas de aspersión

• Chillers

• Enfriadores

• Washing/cleaning systems

• Sistemas de lavado/limpieza

• OEM applications

• Aplicaciones del fabricante del equipo original

• General purpose sump and tank draining

• Sumidero y tanque de desagüe para uso general

NPV SPECIFICATIONS ESPECIFICACIONES NPV Capacities to: 125 GPM (L/min) at 1750 RPM 245 GPM (L/min) at 3500 RPM Heads to: 38 feet (11 m) at 1750 RPM 150 feet (50 m) at 3500 RPM

Motor specifications: NEMA 56J frame, 1750 RPM, 1⁄2 HP and 3⁄4 HP. 3500 RPM 1⁄2 through 71⁄2 HP. Open drip-proof, totally enclosed fan-cooled or explosion proof enclosures. Stainless steel shaft with ball bearings.

Maximum temperatures to: 250°F (121°C)

Single phase: Voltage 115/230 ODP and TEFC. (3 HP model – 230 V only) Built-in overload with autoreset provided.

Direction of rotation: Clockwise when viewed from motor end.

Three phase: Voltage 208230/460 ODP, TEFC and EX PROOF.

Working pressures to: 125 PSIG (9 bars)

NOTE: For three phase motors, overload protection must be provided in starter unit. Starter and heaters must be ordered separately.

Capacidades: 125 GPM (L/min) a 1750 RPM 245 GPM (L/min) a 3500 RPM Alturas de carga a: 39 pies (11 m) a 1750 RPM 150 pies (50 m) a 3500 RPM Presión de trabajo: 125 lib/pulg 2 (9 barias) Temperatura máxima: 250 °F (121°C) Dirección de rotación: En dirección de las agujas del reloj visto desde el extremo final del motor.

Especificaciones de motores: Armazón 56J NEMA, 1750 RPM 1 ⁄2 HP y 3⁄4 HP. 3500 RPM 1⁄2 a 71⁄2 HP CF. A prueba de goteo, totalamente cerrados y enfriados con ventilador o en cubiertas a prueba de explosión. Eje de acero inoxidable con balineras de bolas. Monofásicos: Voltaje 115/230 abiertos a prueba de goteo y totalmente cerrados y enfriados con ventilador. (modelo 3 HP – 230 voltios solamente) Se proporciona protección térmica contra sobrecarga construida con reseteo automático. Trifásicos: Voltaje 208230/460 abiertos a prueba de goteo, totalmente cerrados y enfriados con ventilador y a prueba de explosión. NOTA: Para motores trifásicos se debe de proporcionar la protección térmica contra sobrecarga en la unidad de arranque. El arrancador y los calentadores se deben pedir por separado.

PAGE 17

Goulds Water Technology Commercial Water NOTES NOTAS

PAGE 18

Goulds Water Technology Commercial Water NOTES NOTAS

PAGE 19

Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We’re a global team unified in a common purpose: creating innovative solutions to meet our world’s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com

Xylem Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148 Phone: (866) 325-4210 Fax: (888) 322-5877 www.gouldswatertechnology.com Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. WaterGun is a trademark of Xylem Inc. or one of its subsidiaries. © 2016 Xylem Inc.

BNPV R2

February 2016