EcoSystemTM Switching Power Module for Non-Dim Loads ...

Capable of switching 16 A of high in-rush lighting load. (magnetic fluorescent ... integration of non-dim loads into Lutron's EcoSystem. Bus. The Power Module ...
505KB Größe 9 Downloads 50 vistas
EcoSystemTM

C5-XPJ-16A

EcoSystemTM Switching Module 16A Module-1 09.27.07

EcoSystemTM Switching Power Module for Non-Dim Loads Lutron’s EcoSystem Switching Power Module allows integration of non-dim loads into Lutron’s EcoSystem Bus. The Power Module combines digital commands and sensor data to control the load.

Multiple Fixture Switching Control Contrôle de commutation de multiples luminaires Control interruptor de múltiples lámparas

C5-XPJ-16A

Power Indicator (PWR) On: Unit is powered Off: Unit is not powered or is malfunctioning

Indicateur de puissance (PWR) On: l’unité est alimentée Off: l’unité n’est pas alimentée ou est dysfonctionnelle

Indicador de Alimentación (PWR) Encendido: unidad tiene corriente Apagado: unidad no tiene corriente o no está funcionando correctamente

Status Indicator (STAT) Solid: Circuit Level Pulse: No communication

Indicateur d’activité (STAT) Plein: Niveau de circuit Impulsion: Aucune communication

Indicador de estado (STAT) Sólido: Nivel del Circuito Pulsante: No hay comunicación

EcoSystemTM Class 2 Link Lien Classe 2 Enlace Clase 2

• Capable of switching 16 A of high in-rush lighting load (magnetic fluorescent ballast, electronic fluorescent ballast, HID, incandescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode and motor loads). • Provides 20 V power for and responds to one occupant sensor, one EcoSystem photo sensor, and one EcoSystem personal control input (infrared receiver or wallstation) • Communicates status and sensor levels over the EcoSystem Bus • Universal voltage input: 100 - 277 V 50/60 Hz • Non-volatile (EEPROM) memory stores specific system information for 10 years from power down to power restored • 100% performance tested at factory

Class 2 Sensors

Daylight

IR

Common

+20V

P/N 500-10759

DYLT

Capteurs Classe 2 Sensores Clase 2

OCC

STAT

COM

PWR

E2

E1

E1

E2

Features

EcoSystem One-Line To additional ballasts and modules (up to 64 total)

EcoSystem Bus

EcoSystem Ballast

1 2 3 4 5 6 7 8

Non-Dim Load EcoSystem Bus Supply*

IR Receiver

EcoSystem Ballast

EcoSystem Ballast Daylight Sensor

EcoSystem Switching Occupant Power Module Sensor

Lighting Remote

Keypad

*Does not count as one of the ballasts or modules on the EcoSystem Bus.

R

Job Name: Job Number:

S P E C I F I C AT I O N S U B M I T TA L Model Numbers:

Page 1

EcoSystemTM

C5-XPJ-16A

EcoSystemTM Switching Module 16A Module-2 09.27.07

Specifications Standards

Environment

• UL 916 Listed and CSA 184 Certified • Meets ANSI C62.41 Category A surge protection standards up to and including 6 kV • Manufacturing facilities employ ESD reduction practices that comply with the requirements of ANSI/ESD S20.20 • Lutron Quality Systems registered to ISO 9001.2000

Power • Operating Voltage: 100 - 277 V~ 50/60 Hz • Output Rating: 16 A SoftswitchTM maximum non-dim load • Class 2 Sensor Power: 20 V , 50 mA max. Switchable Load Types • • • • • • • •

Magnetic fluorescent ballast Electronic fluorescent ballast Incandescent and Halogen HID loads Magnetic low-voltage transformer Electronic low-voltage transformer Neon or Cold Cathode Motor Loads -1/4 HP at 100 - 120 V~ -1/2 HP at 200 - 277 V~

• Ambient Temperature Operating Range: 32-104 °F (0-40 °C) • Relative humidity: less than 90% non-condensing • For indoor use only Module Wiring (see pages 4-6 for wiring diagrams) • Terminal blocks accept wires of the following size: EcoSystem Bus (E1, E2): #22 - #12 AWG (.64 - 2.5 mm2) solid wire Class 2 Sensors: #22 - #12 AWG (.64 - 2.5 mm2) solid wire • Wiring between module and load is 3 conductors: Switched Hot Neutral Ground • Wiring between module and sensors shall not exceed manufacturers specifications.

NOTE: Do not use to switch receptacles.

R

Job Name: Job Number:

S P E C I F I C AT I O N S U B M I T TA L Model Numbers:

Page 2

EcoSystemTM

C5-XPJ-16A

EcoSystemTM Switching Module 16A Module-3 09.27.07

Dimensions B

C

Dimensions • A = 7.8 in (200 mm) • B = 5.0 in (130 mm) • C = 2.5 in (65 mm)

A

Electrical Contractors and Engineers

Mounting • Mount the EcoSystem Module onto a 4 x 4 in (102 x 102 mm) standard (1900) junction box (not included, but available; Lutron part number 241-496) • Mount on a vertical or horizontal surface; all power wire connections will be made in the junction box; all EcoSystem bus wiring (Class 1 or 2) and sensor wiring (Class 2 only) connections will be made within the front cover of the unit. • Mount in a location where the PWR and STAT indicators are visable.

• All field installed Class 2 wiring must be separated from line voltage wiring by at least 0.25 in (6.4 mm) • Some local electrical codes require Class 2 wiring to be separately routed in a metal conduit

CEILING W A L L C5-XPJ-16A C5-XPJ-16A

Junction box

R

Job Name: Job Number:

S P E C I F I C AT I O N S U B M I T TA L Model Numbers:

Page 3

EcoSystemTM

C5-XPJ-16A

EcoSystemTM Switching Module 16A Module-4 09.27.07

EcoSystem Power Module Line Voltage Wiring: • Connect the input feed wires and the output load wires to the module as indicated in the wiring diagrams below

White Green

Black Red

EcoSystem Power Module

Green

Green (ground)

White Black

Red (switched hot)

White (neutral)

Fixture Ground Green White

Distribution Panel

Black

Non-Dim Loads

Multiple Fixture Switching Control Contrôle de commutation de multiples luminaires Control interruptor de múltiples lámparas

C5-XPJ-16A

Indicateur de puissance (PWR) Indicador de Alimentación (PWR) On: l’unité est alimentée Encendido: unidad tiene corriente Off: l’unité n’est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente

Status Indicator (STAT) Solid: Circuit Level Pulse: No communication

Indicateur d’activité (STAT) Plein: Niveau de circuit Impulsion: Aucune communication

Indicador de estado (STAT) Sólido: Nivel del Circuito Pulsante: No hay comunicación

Class 2 Sensors

STAT

Capteurs Classe 2 Sensores Clase 2

DYLT

PWR

COM

EcoSystemTM Class 2 Link Lien Classe 2 Enlace Clase 2

P/N 500-10759

Ground Neutral

Power Indicator (PWR) On: Unit is powered Off: Unit is not powered or is malfunctioning

Daylight

OCC

IR

Common

+20V

E1

E2

E2

E1

Hot

Fixture Ground Green White

C5-XPJ-16A

Black

Non-Dim Loads

Colors indicate the module and ballast wire colors and/or ballast terminal colors

R

Job Name: Job Number:

S P E C I F I C AT I O N S U B M I T TA L Model Numbers:

Page 4

EcoSystemTM

C5-XPJ-16A

EcoSystemTM Switching Module 16A Module-5 09.27.07

EcoSystem Bus Wiring • Wire the EcoSystem bus to E1 and E2 terminals on the front of the module. • When the EcoSystem bus is wired Class 1, the bus wiring must enter the left side knock out and maintain .25 in. (6 mm) spacing from the Class 2 sensor wiring. • When the EcoSystem bus is wired Class 2, the bus wiring may enter either knock out on the low voltage wiring area.

EcoSystem Bus Details • E1 and E2 wires are not polarity sensitive • Bus length is limited by the wire gauge used for E1 and E2 as follows: Bus Length (max) Wire Gauge (solid wire) #12 AWG (2.05 mm) 2,200 ft (671 m) #14 AWG (1.63 mm) 1,400 ft (427 m) #16 AWG (1.29 mm) 900 ft (275 m) #18 AWG (1.02 mm) 570 ft (175 m)

Multiple Fixture Switching Control Contrôle de commutation de multiples luminaires Control interruptor de múltiples lámparas

Multiple Fixture Switching Control Contrôle de commutation de multiples luminaires Control interruptor de múltiples lámparas

C5-XPJ-16A

C5-XPJ-16A

Power Indicator (PWR) On: Unit is powered Off: Unit is not powered or is malfunctioning

Indicateur de puissance (PWR) Indicador de Alimentación (PWR) On: l’unité est alimentée Encendido: unidad tiene corriente Off: l’unité n’est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente

Power Indicator (PWR) On: Unit is powered Off: Unit is not powered or is malfunctioning

Indicateur de puissance (PWR) Indicador de Alimentación (PWR) On: l’unité est alimentée Encendido: unidad tiene corriente Off: l’unité n’est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente

Status Indicator (STAT) Solid: Circuit Level Pulse: No communication

Indicateur d’activité (STAT) Plein: Niveau de circuit Impulsion: Aucune communication

Status Indicator (STAT) Solid: Circuit Level Pulse: No communication

Indicateur d’activité (STAT) Plein: Niveau de circuit Impulsion: Aucune communication

Class 2 Sensors

STAT

Capteurs Classe 2 Sensores Clase 2

DYLT

PWR

COM

DYLT

Capteurs Classe 2 Sensores Clase 2

P/N 500-10759

STAT

Indicador de estado (STAT) Sólido: Nivel del Circuito Pulsante: No hay comunicación

P/N 500-10759

EcoSystemTM Class 2 Link Lien Classe 2 Enlace Clase 2

Class 2 Sensors

PWR

COM

EcoSystemTM Class 2 Link Lien Classe 2 Enlace Clase 2

Indicador de estado (STAT) Sólido: Nivel del Circuito Pulsante: No hay comunicación

Class 2 wiring knock out

Daylight

OCC

IR

Common

+20 V

E2

E1

E2

E1

Daylight

OCC

IR

Common

+20 V

E2

E1

E2

E1

EcoSystem Bus wiring knock out

E1 E2 E1 - Purple E2 - Purple/White E1 E2

NOTE: See page 2 for wiring specifications

R

Job Name: Job Number:

S P E C I F I C AT I O N S U B M I T TA L Model Numbers:

To additional EcoSystem modules, ballasts, and the EcoSystem Bus supply

Page 5

EcoSystemTM

C5-XPJ-16A

EcoSystemTM Switching Module 16A Module-6 09.27.07

Low Voltage Wiring Class 2 Sensors Wiring to Class 2 Sensors • Wire color designations of the Class 2 Terminals: Red = 20 V Black = Common White = IR (wallstation / IR receiver) Blue = Occupancy Sensor Yellow = Daylight Sensor Signal

Multiple Fixture Switching Control Contrôle de commutation de multiples luminaires Control interruptor de múltiples lámparas

C5-XPJ-16A

Power Indicator (PWR) On: Unit is powered Off: Unit is not powered or is malfunctioning

Indicateur de puissance (PWR) Indicador de Alimentación (PWR) On: l’unité est alimentée Encendido: unidad tiene corriente Off: l’unité n’est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente

Status Indicator (STAT) Solid: Circuit Level Pulse: No communication

Indicateur d’activité (STAT) Plein: Niveau de circuit Impulsion: Aucune communication

Class 2 Sensors Capteurs Classe 2 Sensores Clase 2

• Wiring between module and sensors shall not exceed manufacturers specifications. • Make sure that the supply breaker to the digital power module is OFF when wiring.

Daylight

OCC

IR

Indicateur de puissance (PWR) Indicador de Alimentación (PWR) On: l’unité est alimentée Encendido: unidad tiene corriente Off: l’unité n’est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente

Status Indicator (STAT) Solid: Circuit Level Pulse: No communication

Indicateur d’activité (STAT) Plein: Niveau de circuit Impulsion: Aucune communication

Daylight

IR

Common

+20 V

E2

E1

E2

E1

P/N 500-10759

DYLT

Class 2 Sensors Capteurs Classe 2 Sensores Clase 2

COM

STAT

Indicador de estado (STAT) Sólido: Nivel del Circuito Pulsante: No hay comunicación

OCC

PWR

P/N 500-10759

DYLT

IR

Common

+20 V

E2

E1

E1

E2

Power Indicator (PWR) On: Unit is powered Off: Unit is not powered or is malfunctioning

EcoSystemTM Class 2 Link Lien Classe 2 Enlace Clase 2

Class 2 Sensors Capteurs Classe 2 Sensores Clase 2

Daylight

STAT

Indicador de estado (STAT) Sólido: Nivel del Circuito Pulsante: No hay comunicación

COM

PWR

Common

Occupant Sensor Wired to Module

Multiple Fixture Switching Control Contrôle de commutation de multiples luminaires Control interruptor de múltiples lámparas

OCC

EcoSystemTM Class 2 Link Lien Classe 2 Enlace Clase 2

+20 V

Blue

C5-XPJ-16A

Indicateur de puissance (PWR) Indicador de Alimentación (PWR) On: l’unité est alimentée Encendido: unidad tiene corriente Off: l’unité n’est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente Indicateur d’activité (STAT) Plein: Niveau de circuit Impulsion: Aucune communication

E2

Red

Multiple Fixture Switching Control Contrôle de commutation de multiples luminaires Control interruptor de múltiples lámparas

Status Indicator (STAT) Solid: Circuit Level Pulse: No communication

E2

Black

C5-XPJ-16A

Power Indicator (PWR) On: Unit is powered Off: Unit is not powered or is malfunctioning

E1

Class 2 wiring knock out E1

Note - The module accepts only one IR Input. Use of the IR output from the EcoSystem Daylight Sensor precludes the use of an IR receiver or wallstation with the module. When both a daylight sensor and wallstation/IR receiver are wired to the same module, the IR wire from the daylight sensor should not be connected.

DYLT

STAT

COM

PWR

P/N 500-10759

EcoSystemTM Class 2 Link Lien Classe 2 Enlace Clase 2

Indicador de estado (STAT) Sólido: Nivel del Circuito Pulsante: No hay comunicación

Black

Black

Red

Red

White Yellow

White Yellow

EcoSystem Daylight Sensor Wired to Module

EcoSystem Daylight Sensor & Wallstation wired to the module (IR wired only to keypad)

NOTE: See page 2 for wiring specifications

R

Job Name: Job Number:

S P E C I F I C AT I O N S U B M I T TA L Model Numbers:

Page 6