Radio RA2 Dimmer_Switch Install Guide 044301

A caga máxima para o -F6AN-DV é a carga reduzida ou o número de balastros, o que for MENOR. Note: -8ANS, -RD-277 and -RS-277 possuem aletas que precisam ser removidas para instalações multigrupos. -6D, -6NA, -10D, -10ND, -F6AN-DV, -8S-DV, -RD and. -RS não possuem abas que precisam ser removidas.
6MB Größe 8 Downloads 12 vistas
Dimmer: R  RD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) Switch: R  RD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz) Typical Power Consumption*: 0.6 W

Remote Dimmers: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Remote Switches: RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) Typical Power Consumption*: 0 W

When combining controls in a wallbox, derating is required; however, no derating is required for remote dimmers / switches. Derating Chart Control

For system Setup Guide and tools visit www.lutron.com/radiora2 Load Specifications: Control

Load Type

-6D1

-6NA1

-10ND1

-F6AN-DV3, 4, 5

-8ANS6

-8S-DV7, 8 9

-RD

Max. Load

Incand.

50 W

600 W

MLV2

50 W / VA

450 W /  600 VA

Incand./ ELV2

5W

600 W

MLV2

5 W / VA

450 W /  600 VA

Incand. -10D1

-6D Min. Load

50 W

1000 W

MLV2

50 W / VA

800 W /  1000 VA

Incand.

10 W

1000 W

MLV2

10 W / VA

800 W /  1000 VA

3-wire Fluorescent/ LED

0.05 A

6A

1 ballast

60 ballasts

Lighting

10 W / VA

8A

Motor

0.08 A

1/4 HP 5.8 A

Lighting

40 W / VA

8A

Motor

0.4 A

1/10 HP 3A

See Dimmer

-RS9

See Switch 10

-RD-277

See Dimmer

-RS-27710

See Switch

8.3 A

1 Dimmer Load Type: -6D, -10D and -10ND are designed for use with permanently installed incandescent, magnetic low-voltage, or tungsten halogen only.  -6NA is designed for use with permanently installed incandescent, electronic low-voltage, magnetic low-voltage, or tungsten halogen only.  Do not install dimmers to control receptacles or motoroperated appliances. Do not mix incandescent, halogen, MLV, or ELV load types on a dimmer. 2 Low-Voltage Applications: Use -6D,-10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers.  Use -6NA with dimmable electronic (solid-state) or magnetic (core and coil) transformers.  Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: a. Do not operate low-voltage circuits without operative lamps in place. b. Replace burned-out lamps as quickly as possible. c. Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. 3 Fluorescent Dimmer Load Type: -F6AN-DV is designed for use with permanently installed 3-wire 120 V~ or 277 V~ line voltage control fluorescent ballasts or LED drivers. Use only with Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, or EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Do NOT use with any other ballasts or drivers. Do not install to control receptacles or motor-operated appliances. 4 Power Boosters / Load Interfaces: -6NA, -10ND, -F6ANDV, and -8ANS can be used to control power boosters / load interfaces. For a list of compatible power boosters / load interfaces see Lutron P/N 369225. 5 Maximum Load: The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS. 6 Switch Load Type -8ANS: -8ANS is designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, or fluorescent loads and with motor loads up to 1/4 HP (5.8 A). 7 Switch Load Type -8S-DV: -8S-DV is designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, fluorescent, or motor loads; or 277 V~ magnetic low-voltage or fluorescent loads. 8 Shunt Capacitor (included): Some -8S-DV installations may require the use of a shunt capacitor. This is especially necessary for load types sensitive to leakage current (i.e. fluorescent ballasts). If load flickers, install a shunt capacitor. For shunt capacitor installation see Wiring Diagram 4 or 8. 9 120 V~ Remote Dimmer / Switch: -RD and -RS are designed for use with 120 V~ dimmers / switches. 10 277 V~ Remote Dimmer / Switch: -RD-277 and -RS-277 are designed for use with 277 V~ dimmers / switches. Do NOT use with motor loads.

Dimmer

Switch

Remote Dimmer

Remote Switch

Important Notes WARNING – Entrapment Hazard – To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment which is not visible from every control location or which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death. Codes: Install in accordance with all local and national electrical codes. Grounding: When no “grounding means” exist in wallbox, the 2011 National Electrical Code® (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove green wire before screwing control into wallbox.

-6NA

-10D, -10ND

-F6AN-DV*

-8ANS

Load Type

End of Gang

Middle of Gang

Incand.

500 W

400 W

MLV

400 W /  500 VA

300 W /  400 VA

Incand./ ELV

500 W

400 W

MLV

400 W /  500 VA

300 W /  400 VA

Incand.

800 W

650 W

MLV

600 W /  800 VA

500 W /  650 VA

3-wire Fluorescent/ LED

5A 50 ballasts

3.5 A 35 ballasts

Lighting

6.5 A

5A

Motor

1/4 HP 5.8 A

1/6 HP 4.4 A

Lighting

8A (2-gang) 7A (3-gang)

Motor

1/10 HP 3A

-8S-DV

7A

Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions. Wallboxes: Lutron recommends using 3 ½ in (89 mm) deep wallboxes for easier installation. Several controls may be installed in one multigang wallbox. See Derating Chart. Remote Dimmers / Switches: Use only remote dimmers (RD-RD / RD-RD-277) and remote switches (RD-RS / RD-RS-277) with dimmers /switches. Up to 9 RD-RD / RD-RD-277 or RD-RS /RD-RS-277 may be used with controls. Mechanical 3- or 4-way switches will not work. RF Device Placement: RF dimmers /switches must be located within 30 ft (9 m) of an RF Signal Repeater. Remote dimmers / switches are not required to be within a specific range of a repeater. For systems with an RF signal repeater, RF dimmers / switches cannot be controlled by the system until they are programmed in a system according to the system Setup Guide.

Note: Wire connectors provided are suitable for copper wire only. Wire Connector: •S  trip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm2) or 12 AWG (2.5 mm2) wire. • Strip insulation 7/16 in (11 mm) for 18 AWG (0.75 mm2) or 16 AWG (1.0 mm2) wire. •U  se to join one or two 14 AWG (1.5 mm2) or 12 AWG (2.5 mm2) wires with one 18 AWG (0.75 mm2) or 16 AWG (1.0 mm2) wire.

Twist wire connector tight.

Control at middle of gang has all fins removed

Dimmer Brass

WARNING – Shock Hazard – To avoid the risk of electric shock locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON could result in serious injury or death.

Black

3. W  ire controls according to one of the following options: a. T  erminals: Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control. • Push-In Terminals: Use with 14 AWG (1.5 mm2) solid copper wire only. Do NOT use stranded or twisted wire. Insert wires fully. To release wire, insert small, flat screwdriver into slot below push-in terminal. Push screwdriver in while pulling wire out. OR

Neutral

c. S  nap wallplate onto wallplate adapter, and verify that control is aligned properly.

6. R  estore power. Verify correct local operation. See Dimmer Operation or Switch Operation.

Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-301 Rev. B 02 / 2012

Load

Wiring Diagram 4

Single Location Installation1 with Neutral -F6AN-DV (120/277 V~)

Single Location Installation1 without Neutral -8S-DV with optional shunt capacitor2 (120-277 V~)

Dimmer Black

Blue 1

Brass

Orange

Silver

Orange

White

Black Green

120/277 V~ 50/60 Hz

Black Orange

Ground

White

Neutral

Blue 1

Black

Load Ground

Multi-Location Installation without Neutral -6D, -10D with -RD (120 V~)

Brass

Black

Green

Lamp Replacement WARNING – Shock Hazard – For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. Working with power ON could result in serious injury or death. For your safety during routine lamp replacement, remove power from the fixture(s) by moving the FASSTM switch into the OFF position on the dimmer / switch and all remote dimmers / switches.

Dioded lamps • If dioded lamps are being used, replace with non-dioded lamps. Load flickers or tapswitch does not work even if load is greater than 40 W (-8SDV only)

Leakage current • Install a shunt capacitor. See Wiring Diagram 4 or 8.

Light turns ON and OFF continuously or lights turn ON when tapswitch is pressed, then turn OFF

Load does not meet the minimum load requirement • Increase load to meet the appropriate minimum load requirement for that control. See Load Specifications. • Install a shunt capacitor with -8S-DV. See See Wiring Diagram 4 or 8. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or -8ANS. See Load Specifications.

Load flickers (-8S-DV only)

Load does not meet the minimum load requirement • Increase load to meet the appropriate minimum load requirement for that control. See Load Specifications. • Install a shunt capacitor. See Wiring Diagram 4 or 8.

Lights don’t turn ON/OFF from a keypad

Improper programming • Program according to the system Setup Guide.

Note: Dimmer may be installed in any location in the circuit.

Green

Ground

Ground

Wiring Diagram 6 Multi-Location Installation3 with Neutral4 -6NA and -10ND with RD-RD, and -8ANS with RD-RS (120 V~) Remote Dimmer/ Remote Switch

Brass

Blue

Black

Brass

Blue

Black

Green

120 V~ 50/60 Hz

Note: Dimmer must be installed on the load side of the circuit. Dimmer / Switch

Remote Dimmer/ Remote Switch

Brass Silver

Hot/Live

Out of RF range • Reposition to be within 30 ft (9 m) of an RF signal repeater. Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams.

Blue

Black

Green

Ground

Green

Ground

Load

Ground

Neutral

Wallplate is warm

Solid-state control dissipation • Solid-state dimmers / switches internally dissipate about 2% of the total connected load. It is normal for dimmers /switches to feel warm to the touch during operation.

Note: Refer to the system Setup Guide for additional troubleshooting suggestions.

Wiring Diagram 7 Multi-Location Dimmer Installation3 with Neutral 4 -F6AN-DV with -RD or -RD-277 (120/277 V~) Remote Dimmer

Brass/ Red

Remote Dimmer

Blue

Brass/ Red

Blue

Black

Black 120/277 V~ 50/60 Hz

Note: Dimmer must be installed on the load side of the circuit.

 Dimmer 

Brass Silver

Hot/Live

Black

Blue

Orange

Orange

White

Black

Green

Green

Green

Ground

Ground

Ground

Black Orange White

Neutral

Wiring Diagram 8 Multi-Location Installation 3 without Neutral -8S-DV with -RS or -RS-277 and optional shunt capacitor2 (120– 277 V~)

Brass/ Red

Wallplate adapter and wallplate purchased separately.

Green

Blue

Black

Shunt Capacitor2

Neutral

Control

Mounting Screws (2)

Brass

Load Ground

Remote Switch / Switch3

Wire Connectors (1 or 5)

Blue

Lamps burned out or not installed • Replace or install lamps.

Optional

Green

120-277 V~ 50/60 Hz

3

Blue

Load is less than minimum load requirement • Make sure the connected load meets the appropriate minimum load requirement for that control. See Load Specifications. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or -8ANS. See Load Specifications.

Hot/Live

Wiring Diagram 5

Wallbox

Included:

Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or-8ANS. See Load Specifications.

Switch Brass

Neutral

Mounting Diagram Wallplate Wallplate Control Adapter Adapter Mounting Mounting Screws Screws

Power not present • Circuit breaker OFF or tripped. Perform short circuit check. • FASS™ is in the OFF position. Move FASS™ to the ON position. Check the dimmer / switch and all of the remote dimmers / switches. See Lamp Replacement.

Ground

Wiring Diagram 3

5. A  ttach the Lutron® Claro® or Satin Colors® wallplate adapter and wallplate. See Mounting Diagram.

b. T  ighten control mounting screws until wallplate adapter is flush to wall (do not over-tighten).

Probable Cause and Action

Lights don’t turn ON / OFF when tapswitch on dimmer / switch or remote dimmer / switch is pressed

Neutral

Brass

For single and multi-location installations see Wiring Diagrams.

Symptom

Green

120 V~ 50/60 Hz

Load Ground

Remote Switch / Switch3

Brass/ Red

Blue

Blue

Switch / Remote Switch3

Brass/ Red

Note: Switch may be installed in any location in the circuit. Blue

Hot/Live Black 120–277 V~ 50/60 Hz

Green

Black

Green

Black

Optional

Green

Shunt Capacitor2

Load Ground

Ground

Ground

Neutral

1W  hen using controls in single location installations, tighten the blue terminal without any wires attached. DO NOT connect the blue terminal to any other wiring or to ground. 2 Shunt capacitor must be installed inside the load fixture or in a separate J-box. 3 Install only 1 dimmer / switch per circuit. Up to 9 remote dimmers / switches may be connected to a dimmer / switch. Total blue terminal wire length may be up to 250 ft (76 m). 4 Neutral wire dimmers / switches  must be connected on the Load side of a multi-location installation.

Dimmer Operation

Switch Operation

Status LEDs (Dimmer only) Indicate light level; glows softly as night light when load is off Tapswitch Tap on/off

Status LED (Switch only) Indicates light status; glows softly as night light when load is off

Dimming Rocker Press to Brighten

Tapswitch Tap on/off

Press to Dim 

*Typical Power Consumption test conditions: Dimmer / Switch: load is off, nightlight mode enabled. Remote Dimmer / Switch: load is off.

Technical Assistance: U.S.A. / Canada: 1.800.523.9466 | Mexico: +1.888.235.2910 Brazil: +55 (11) 3257-6745 (M-F 8:30 to 17:30 BRT) | Other Countries: +1.610.282.3800 24 hours a day, 7 days a week www.lutron.com

Blue 1

Black

Green

120 V~ 50/60 Hz

1. T  urn power OFF at fusebox or circuit breaker. 2. C  heck the installation for short circuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load. Restore power. If lights do not work or a breaker trips, check wiring. Correct wiring and check again. Install control(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit.

Brass Silver

Hot/Live

Hot/Live 120 V~ 50/60 Hz

d. If controls are misaligned, loosen mounting screws appropriately.

Installation

Dimmer/Switch Blue 1

Hot/Live Black

a. Install wallplate adapter onto front of control(s).

Each control has inside fins removed

Single Location Installation1 with Neutral -6NA, -10ND, and -8ANS (120 V~)

Remote Dimmer / Dimmer3 Remote Dimmer / Dimmer3  Dimmer / Remote Dimmer3

4. P  ush all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws provided. Do not pinch the wires. Do Not remove outside fins on controls at the end of gang

Wiring Diagram 2

Single Location Installation1 without Neutral -6D, -10D (120 V~)

Hot/Live

the number of ballasts, whichever is LESS.

Note: -8ANS, -RD-277 and -RS-277 controls have fins that need to be removed for multigang installations. -6D, -6NA, -10D, -10ND, -F6AN-DV, -8S-DV, -RD and -RS controls do not have fins that need to be removed for multigang installations.

Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only.

Wallplates: Lutron® Claro® and Satin Colors® wallplates are recommended for best color match and aesthetic appearance. Do not paint controls or wallplates.

b. W  ire Connectors: Prepare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connector.

*The maximum load for the -F6AN-DV is either the derated load or

Neutral Wire: -6NA, -10ND, -8ANS and -F6AN-DV require a neutral wire connection in the wallbox where the dimmer/switch is to be installed. If a neutral wire connection is not available in the wallbox, contact a licensed electrician for installation.

Spacing: If mounting one control above another, leave at least 4 ½ in (114 mm) vertical space between them.

Wrap wire around screw terminal. Tighten securely to 5 in-lb (0.55 N•m).

Troubleshooting Guide

Wiring Diagram 1

Lutron® Ballast / LED Driver

Designer-Style RF Maestro®

• Screw Terminals: Use with 12 AWG (2.5 mm2) or 14 AWG (1.5 mm2) solid copper wire only. Do NOT use stranded or twisted wire.

Lutron® Ballast / LED Driver

In multigang installations, several controls are grouped horizontally in one multigang wallbox.

Lutron® Ballast / LED Driver

Multigang Installations

Please Read Before Installing

Lutron® Ballast / LED Driver

English Installation Instructions

FASS™ Front Accessible Service Switch

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, and ) are registered trademarks and RadioRA 2, Hi-lume 3D, Compact SE, and FASS are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc.

FASS™ Front Accessible Service Switch

-RD-277 or -RS-277 only OR OFF

ON

Returning Dimmers / Switches to Factory Settings

Note: Returning a dimmer / switch to its factory settings will remove it from the system and erase all programming from it. Step 1 : T  riple tap the tapswitch on a control. DO NOT release after the third tap. Step 2 : K  eep the tapswitch pressed on the third tap (for approximately 3 seconds) until the LEDs on the dimmer start to scroll up and down quickly, or the LED on the switch flashes quickly Step 3 : Release the tapswitch and immediately triple tap the tapswitch again. The LEDs on the dimmer will scroll up and down slowly. The LED on the switch will flash slowly. The control has now been returned to factory settings and needs to be reprogrammed into a system.

Warranty: For warranty information, please see the enclosed Warranty, or visit http://www.lutron.com/TechnicalDocumentLibrary/HomeWorks_Warranty.pdf

Instalaciones con múltiples dispositivos

Atenuadores accesorios: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Interruptores accesorios: RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) Consumo típico de potencia*: 0 W

En instalaciones con dispositivos múltiples, se agrupan varios controles horizontalmente en una caja de empotrar para dispositivos múltiples. Cuando se combinan atenuadores / interruptores en una caja de empotrar se requiere reducir la potencia nominal. Esto no es necesario para los atenuadores / interruptores accesorios. Cuadro de Reducción de la Potencia Nominal

Para la Guía de configuración del sistema y otras herramientas visite: www.lutron.com/radiora2

Control

Tipo de carga

Extremos de la agrupación

Medio de la agrupación

Incand.

500 W

400 W

BVM

400 W /  500 VA

300 W /  400 VA

Incand./ BVE

500 W

400 W

Especificaciones de la carga: Control

-6D1

Tipo de carga

Carga mín.

Carga máx.

Incand.

50 W

600 W

50 W / VA

450 W /  600 VA

BVM2 2

Incand./ BVE

5W

600 W

BVM2

5 W / VA

450 W /  600 VA

Incand.

50 W

1 000 W

BVM

50 W / VA

800 W /  1 000 VA

Incand.

10 W

1 000 W

-6NA1

-10D1

2

-10ND1

3, 4, 5

-F6AN-DV

BVM2

10 W / VA

800 W /  1 000 VA

Fluorescente de 3 conductores / LED

0,05 A

6A

1 balasto

60 balastos

Iluminación -8ANS6

10 W / VA

Motor

0,08 A

1/4 HP 5,8 A

Iluminación

40 W / VA

8A

0,4 A

1/10 HP 3A

7, 8

-8S-DV

8A

Motor

-RD9

Ver el Atenuador

-RS9

Vea Interruptor

-RD-27710

Ver el Atenuador

-RS-27710

Vea Interruptor

8,3 A

1 Tipo de carga del atenuador: Los modelos -6D, -10D y -10ND están diseñados para usarse solamente con cargas incandescentes, magnéticas de bajo voltaje, o halógenas de tungsteno instaladas en forma permanente.  El modelo -6NA está diseñado para usarse solamente con cargas incandescentes, electrónicos de bajo voltaje, magnéticas de bajo voltaje, o halógenas de tungsteno instaladas en forma permanente.  No instale atenuadores para controlar tomas de corriente ni dispositivos motorizados. No combinar tipos de carga incandescente, halógena, BVM o BVE en un atenuador. 2 Uso con bajo voltaje: Use los modelos -6D, -10D y -10ND solamente con transformadores magnéticos (de bobina y núcleo) de bajo voltaje. No los use con transformadores electrónicos (de estado sólido).  Use el modelo -6NA con transformadores atenuables electrónicos (de estado sólido) o magnéticos (de bobina y núcleo) de bajo voltaje.  El funcionamiento de un circuito de bajo voltaje sin lámparas o con lámparas que no funcionan puede resultar en el sobrecalentamiento del transformador y fallas prematuras. Lutron recomienda firmemente lo siguiente: a. N  o opere circuitos de bajo voltaje sin las lámparas en condiciones operativas en su lugar. b. Reemplace las lámparas quemadas lo más rápido posible. c. U  se transformadores que incorporan protección térmica o con fusibles en los bobinados primarios para prevenir fallas del transformador provocadas por sobrecorrientes. 3 Tipo de carga del atenuador para luces fluorescentes: El -F6AN-DV está diseñado para ser usado con drivers de LED o balastos de luces fluorescentes de 3 conductores, de 120 V~ o 277 V~, instalados en forma permanente y controlados a través del voltaje de línea. Use sólo con Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, o EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). NO usar con otros balastos o drivers. No lo instale para controlar tomas de corriente ni electrodomésticos operados por motor. 4 Amplificadores de potencia / Interfaces de carga: -6NA, -10ND, -F6AN-DV, y -8ANS se pueden utilizar para controlar amplificadores de poder/interfaces de carga. Para obtener una lista de amplificadores de poder/interfaces de carga compatibles, consulte Lutron P/N 369225. 5 Carga Máxima: La carga máxima para el -F6AN-DV es la carga reducida o el número de balastos, lo que fuera MENOR. 6 Tipo de carga del interruptor -8ANS: el modelo -8ANS está diseñado para usar con cargas incandescentes, de bajo voltaje magnético, de bajo voltaje electrónico, o fluorecentes instaladas en forma permanente y con cargas de motores de hasta 1/4 HP (5,8 A). 7  Tipo de carga del interruptor -8S-DV: El -8S-DV está diseñado para uso con cargas permanentemente instaladas de 120 V~, incandescentes, de bajo voltaje magnético o electrónico, fluorescentes, o motores; o con cargas de 277 V~, fluorescentes o de bajo voltaje magnético). 8  Condensador paralelo (incluido): ciertas instalaciones -8S-DV pueden requerir el uso de un condensador paralelo. Esto es especialmente necesario con tipos de carga sensibles a la corriente de fuga (por ejemplo balastos fluorescentes). Si la carga parpadea, instale un condensador en paralelo. Para la instalación del condensador paralelo vea el Diagrama de cableado 4 o 8. 9  Atenuador / interruptor accesorio de 120 V~: Los -RD y -RS están diseñados para usar con atenuadores / interruptores de 120 V~. 10 Atenuador / interruptor accesorio de 277 V~: Los -RD-277 y -RS-277 están diseñados para usar con atenuadores / interruptores de 277 V~. NO utilizar con una carga motorizada.

Atenuador

Interruptor

Atenuador accesorio

-6D

Notas importantes ADVERTENCIA – Riesgo de quedar atrapado – Para evitar el riesgo de quedar atrapado, de lesiones graves o la muerte, estos controles no deben usarse para controlar equipos que no sean visibles desde todos los puntos de control o que puedan causar situaciones peligrosas, como quedar atrapado, si se operan accidentalmente. Como ejemplos de equipos que no deben operarse con estos controles podemos citar (sin limitación) portones motorizados, puertas de garaje, puertas industriales, hornos de microondas, almohadillas de calentamiento, etc. Es responsabilidad del instalador asegurar que el equipo que se controla sea visible desde todos los puntos de control y que sólo se conecten equipos adecuados a estos controles. La falta de cumplimiento podría resultar en lesiones graves o la muerte. Códigos: Realice la instalación de acuerdo con todos los códigos eléctricos locales y nacionales. Conexión a tierra: Cuando dentro de la caja de empotrar no hay “medios de conexión a tierra”, el National Electrical Code® 2011 permite la instalación de un control como reemplazo, siempre y cuando 1) se utilice una placa frontal no metálica e incombustible con tornillos de fijación no metálicos o 2) el circuito se encuentre protegido por un interruptor de circuitos de fallas de conexión a tierra (GFCI). Al instalar un control de acuerdo con estos métodos, tape o retire al cable verde antes de atornillar el control en la caja de empotrar.

-6NA

-10D, -10ND

-F6AN-DV*

-8ANS

BVM

400 W /  500 VA

300 W /  400 VA

Incand.

800 W

650 W

BVM

600 W /  800 VA

500 W /  650 VA

Fluorescente de 3 conductores / LED

5A 50 balastos

35 balastos

Iluminación

6,5 A

5A

Motor

1/4 HP 5,8 A

Iluminación

8A (2-dispositivos) 7A (3-dispositivos)

-8S-DV

Motor

Placas: Las placas Claro® y Satin Colors® de Lutron® se recomiendan para una mejor combinación de colores y aspecto estético. No pinte los controles ni las placas. Limpieza: Para limpiar, pase un trapo húmedo. NO use ninguna solución química. Cajas de empotrar: Para facilitar la instalación, Lutron recomienda el uso de cajas de empotrar de 89 mm (3 ½ pulg) de profundidad. Varios controles pueden instalarse en una caja para dispositivos múltiples – vea el Cuadro de Reducción de la Potencia Nominal. Atenuadores / Interruptores remotos: utilice solamente los atenuadores remotos (-RD / -RD-277) e interruptores remotos (-RS / -RS-277) con atenuadores / interruptores. Con estos atenuadores o interruptores pueden usarse hasta 9 -RD / -RD-277 o -RS / -RS-277. Los interruptores mecánicos de 3 o 4 vías no funcionarán. Ubicación del dispositivo de RF: los atenuadores / interruptores de RF deben ubicarse a menos de 9 m (30 pies) de un repetidor de señales de RF. Los atenuadores / interruptores accesorios no están sujetos a esta limitación de estar ubicados a cierta distancia de un repetidor. En sistemas con un repetidor de señal de RF, los atenuadores / interruptores RF no pueden ser controlados por el sistema hasta que hayan sido programados de acuerdo con la Guía de configuración del sistema.

Asistencia Técnica: E.U.A. / Canadá: 1.800.523.9466 | México: +1.888.235.2910 Brasil: +55 (11) 3257-6745 (Lunes-Viernes 8:30 to 17:30 BRT) | Otros países: +1.610.282.3800 24 horas al día, los 7 días de la semana www.lutron.com

Latón



b. C  onectores de cable: Prepare los cables. Al hacer conexiones de cable, siga las longitudes para extremos pelados y las combinaciones recomendadas para los conectores proporcionados.

•P  ele 10 mm (3/8 pulg) de aislamiento para cables de 1,5 mm2 (14 AWG) o 2,5 mm2 (12 AWG). • Pele 11 mm (7/16 pulg) de aislamiento para cables de 0,75 mm2 (18 AWG) o 1,0 mm2 (16 AWG). •U  se para unir uno o dos cables de 1,5 mm2 (14 AWG) o 2,5 mm2 (12 AWG) con un cable de 0,75 mm2 (18 AWG) o 1,0 mm2 (16 AWG).

A cada control se le han quitado las aletas interiores

Al control en medio de la agrupación se le han quitado todas las aletas

Instalación ADVERTENCIA – Peligro de descarga eléctrica – Para evitarla, ubique y retire el fusible o asegure el disyuntor en la posición de APAGADO antes de proceder. Cablear con la alimentación ENCENDIDA podría causar lesiones graves o la muerte. 1. D  ESCONECTE la alimentación en la caja de fusibles o en el disyuntor.

5. C  oloque el adaptador y la placa Lutron® Claro® o Satin Colors®. Consulte Diagrama de montaje.

a. Instale el adaptador de la placa sobre el frente del (los) control(es).



b. A  juste los tornillos de montaje del control hasta que el adaptador de placa esté a ras con la pared (no los sobreajuste).



c. P  resione la placa sobre el adaptador y verifique que el control esté correctamente alineado.



d. S  i los controles quedaron mal alineados, afloje los tornillos de montaje según corresponda.

6. R  establezca la alimentación. Verifique que el funcionamiento local sea correcto. Consulte Operación del atenuador u Operación del interruptor.

Diagrama de montaje Tornillos de Adaptador montaje de placa del control

Conectores de cable (1 o 5)

3. C  ablee los controles de acuerdo con una de las opciones siguientes:

Tornillos de montaje (2)

a. T  erminales: Recorte o pele los cables de la caja de empotrar hasta la medida indicada en el reverso del control.

Reemplazo de lámparas

Inserte completamente los cables. Para soltar el cable, inserte un destornillador chato pequeño dentro de la ranura debajo del terminal a presión. Empuje el destornillador mientras tira el cable hacia afuera. O

Atenuador Negro

Azul1

Latón Plateado

Naranja

Naranja

Blanco

Negro

Negro Negro Naranja

Tierra

Blanco

Neutro

Opcional

Verde

120-277 V~ 50/60 Hz

Condensador paralelo2

Carga Tierra

Neutro

Las lámparas están quemadas o no están instaladas. • Reemplace o instale lámparas.

Diagrama de cableado 5 Instalación de un interruptor en múltiples ubicaciones -6D, -10D with -RD (120 V~)

3

Atenuador accesorio/ Atenuador3

Atenuador accesorio/ Atenuador3

Lámparas de diodo • Si se están usando lámparas de diodo, reemplácelas por lámparas sin diodos.

Atenuador3/ Atenuador accesorio Nota: El attenuador puede ser instalado en cualquier lugar del circuito.

Latón

Azul

Latón

Verde

Negro

Azul

Azul

Latón

Verde

Negro

Verde

Carga Tierra

Tierra

Tierra

La carga parpadea o interruptor a presión no funciona incluso si la carga es superior a 40 W (-8S-DV solamente)

Corriente de fuga • Instale un condensador paralelo. Vea el Diagrama de cableado 4 o 8.

La luz se ENCIENDE y se APAGA continuamente o las luces se ENCIENDEN cuando se presiona el interruptor, luego se APAGAN

La carga no cumple con los requisitos de carga mínima • Aumente la carga para cumplir con los requisitos de carga mínima de ese control. Vea Especificaciones de la carga. • Instale un condensador en paralelo con el -8S-DV. Vea el Diagrama de cableado 4 o 8. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga.

La carga parpadea (-8S-DV solamente)

La carga no cumple los requisitos mínimos de carga • Aumente la carga para cumplir con los requisitos de carga mínima de ese control. Vea Especificaciones de la carga. • Instale un condensador paralelo. Vea el Diagrama de cableado 4 o 8.

Las luces no se ENCIENDEN/ APAGAN desde un teclado

Programación incorrecta • Programe todos los dispositivos según la Guía de configuración del sistema.

Instalación3 con control desde varios lugares, con neutro4 -6NA y-10ND con RD-RD, y -8ANS con RD-RS (120 V~) Accesorio atenuador o interruptor accesorio

Latón

Accesorio atenuador o interruptor accesorio

Azul

Atenuador o interruptor

Azul

Latón

Negro

Verde

120 V~ 50/60 Hz

Negro

Negro

Verde

Tierra

Nota: El atenuador debe ser instalado del lado de la carga del circuito

Azul

Latón Plata

Vivo

Verde

Tierra

Carga

Tierra

Fuera del alcance de RF • Reubique para estar a no más de 9 m (30 pies) de un repetidor de señales de RF.

Neutro

Diagrama de cableado 7

Cableado • Cables en cortocircuito. Asegúrese de que el terminal azul no esté conectado a tierra o en cortocircuito con otros cables. • Error en el cableado. Verifique el cableado para asegurarse de que cumpla con las instrucciones de instalación y con los diagramas de cableado.

Instalación3 de un atenuador en múltiples ubicaciones con neutro4 -F6AN-DV con -RD o -RD-277 (120/277 V~) Atenuador accesorio

Atenuador accesorio

Latón/ Rojo

Latón/ Rojo

Azul

Negro 120/277 V~ 50/60 Hz

Nota: El atenuador debe ser instalado del lado de la carga del circuito

Atenuador

Latón

Azul

Azul

Plateado

Vivo Negro

Naranja

Negro Naranja Blanco

Negro

Verde

Verde

Verde

Tierra

Tierra

Tierra

Negro Naranja Blanco

Neutro

La placa de pared está caliente

Disipación de calor del control de estado sólido • Los atenuadores / interruptores de estado sólido disipan internamente cerca del 2% de la carga total conectada. Es normal que se sientan tibios durante el funcionamiento.

Nota: Consulte la Guía de configuración del sistema para sugerencias adicionales de solución de problemas.

Diagrama de cableado 8 Instalación de un interruptor en múltiples ubicaciones3 -8S-DV con -RS o -RS-277 y condensador paralelo opcional2 (120– 277 V~) Interruptor accesorio/ Interruptor3

Interruptor accesorio/ Interruptor3

Interruptor3/ Interruptor accesorio

Latón/ Rojo

Latón/ Rojo

Latón/ Rojo

Nota: El interruptor puede ser instalado en cualquier lugar del circuito. Azul

Azul

Azul

Vivo Negro

Se incluye:

La carga es menor que la carga mínima requerida • Asegúrese de que la carga conectada cumpla con los requerimientos de carga mínima para ese control. Vea la Especificaciones de carga. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga.

Azul1

Vivo

Verde

120/277 V~ 50/60 Hz

120–277 V~ 50/60 Hz

Caja de empotrar

Cableado • Cables en cortocircuito. Asegúrese de que el terminal azul no esté conectado a tierra o en cortocircuito con otros cables. • Error en el cableado. Verifique el cableado para asegurarse de que cumpla con las instrucciones de instalación y con los diagramas de cableado. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga.

Interruptor Latón

Diagrama de cableado 6

4. Inserte todos los cables en la caja de empotrar y coloque el control en la caja usando los tornillos de montaje provistos. No pellizque los cables.

No hay alimentación • Disyuntor APAGADO o se disparó. Verifique si hay cortocircuito. • Interruptor FASS™ en la posición de APAGADO. Cambie el FASS™ a la posición de ENCENDIDO. Verifique el atenuador / interruptor y todos los atenuadores / interruptores accesorios. Consulte Reemplazo de lámparas.

Instalación1 en un solo lugar sin neutro -8S-DV con condensador paralelo opcional2 (120-277 V~)

Neutro

Para instalaciones en una sola y múltiples ubicaciones vea el diagramas de cableado.

Probable Causa y Acción

Las luces no se ENCIENDEN / APAGAN cuando se presiona el interruptor de presión del atenuador / interruptor o del atenuador / interruptor accesorio

Diagrama de cableado 4

Instalación1 en un solo lugar con neutro -F6AN-DV (120/277 V~)

Negro

Gire el conector de cable para afirmarlo

Síntoma

Neutro

120 V~ 50/60 Hz

2: V  erifique que no haya cortocircuitos en la instalación antes de instalar el(los) control(es). Con la alimentación DESCONECTADA, instale interruptores mecánicos estándar entre el vivo y la carga. Restablezca la alimentación. Si las luces no funcionan o un disyuntor se dispara, corrija el cableado y verifique nuevamente. Instale el(los) control(es) solamente cuando ya no haya cortocircuito. La garantía es nula si el control se ENCIENDE con un cortocircuito.

• Terminales de insertar: Use únicamente con cables de cobre sólido de 1,5 mm2 (14 AWG). NO utilice cable trenzado ni retorcido.

Carga

Tierra

Tierra

Vivo

Note: Los controles -8ANS, -RD-277 and -RS-277 tienen aletas que se deben quitar para instalaciones de dispositivos múltiples.

No quite las aletas exteriores de los controles en ambos extremos de la agrupación

Verde

120 V~ 50/60 Hz

Carga

Diagrama de cableado 3

Vivo

Azul1

Negro

Verde

Neutro

7A

Los controles -6D, -6NA, -10D, -10ND, -F6AN-DV, -8S-DV, -RD and -RS no tienen aletas que deban quitarse para instalaciones de dispositivos múltiples.

Vivo Negro

Conector de cable:

1/6 HP 4,4 A

Latón Plata

Azul1

120 V~ 50/60 Hz

Nota: Los conectores provistos son para cable de cobre solamente.

3,5 A

Atenuador / Interruptor

Vivo

Envuelva el cable alrededor del tornillo del terminal. Apriete con firmeza hasta 0,55 N•m (5 pulg-lbs).

1/10 HP 3A

Condiciones ambientales: Temperatura ambiente de operación: de 0 ºC a 40 °C (32 °F a 104 °F), humedad de 0% a 90%, sin condensación. Sólo para uso en interiores. Espaciado: Si se monta un control sobre otro, deje por lo menos 114 mm (4 ½ pulg) de espacio vertical entre ellos.

Interruptor

*La carga máxima para el -F6AN-DV es la carga reducida o el número de balastos, lo que fuera MENOR.

Cables neutros: Los modelos -6NA, -10ND, -8ANS y -F6AN-DV requieren una conexión de neutro en la caja de empotrar en que se instalará el atenuador o interruptor. Si no hay disponible una conexión de neutro en la caja de empotrar, contacte a un electricista autorizado para instalarlo.

*Condiciones de la prueba de consumo típico de potencia Atenuador / interruptor: la carga está apagada, el modo de luz nocturna está habilitado. Atenuador / interruptor accesorio: la carga está apagada.

Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-301 Rev. B 02 / 2012

Interruptor accesorio

Instalación1 en un solo lugar con neutro -6NA, -10ND, y -8ANS (120 V~)

Driver Lutron® de balasto/ LED

Atenuador: R  RD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) Interruptor: R  RD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz) Consumo típico de potencia*: 0.6 W

Guía para la solución de problemas

Diagrama de cableado 2

Instalación1 en un solo lugar sin neutro -6D, -10D (120 V~)

Driver Lutron® de balasto/ LED

Maestro® RF estilo Designer

Diagrama de cableado 1 • Terminales de tornillo: Use solamente con cables de cobre sólidos de 2,5 mm2 (12 AWG) ó 1,5 mm2 (14 AWG). NO utilice cable retorcido ni trenzado.

Driver Lutron® de balasto/ LED

Por favor, lea antes de instalar

Driver Lutron® de balasto/ LED

Español Instrucciones de instalación

Verde

Negro

Verde

Negro

Opcional

Verde

Condensador paralelo2

Carga Tierra

Tierra

Tierra

Neutro

Control El adaptador y la placa se venden por separado.

ADVERTENCIA – Peligro de choque eléctrico – Para cualquier otro procedimiento que no sea el reemplazo habitual de las lámparas se debe desconectar la alimentación desde el panel eléctrico principal. Trabajar con la alimentación CONECTADA puede resultar en lesiones personales graves o la muerte. Para su seguridad durante el reemplazo rutinario de lámparas, desconecte la alimentación del(los) artefacto(s) tirando hacia afuera el interruptor FASSTM, a la posición APAGADO, en el atenuador / interruptor y también en todos los atenuadores / interruptores accesorios.

1C  uando se usan controles en instalaciones con control desde un solo lugar, ajuste el terminal azul sin conectar ningún cable al mismo. NO conecte el terminal azul a ningún otro cable ni a tierra. 2 El condensador paralelo debe ser instalado dentro del artefacto de carga o en una caja J separada. 3 Instalar solamente una (1) atenuador / interruptor por circuito. A un mismo atenuador / interruptor pueden conectarse hasta 9 atenuadores / interruptores accesorios. El largo total del cable del terminal azul puede ser hasta 76 m (250 pies). 4 Los atenuadores / interruptores con cable neutro deben conectarse del lado de la carga de una instalación desde múltiples lugares.

Uso del atenuador

Uso del interruptor LED de estado (interruptor solamente) Indica el estado de luz; brilla suavemente como luz nocturna cuando la carga está apagada

LEDs de estado (atenuador sólo) Indican el nivel de luz; brillan suavemente como luz nocturna cuando la carga está apagada Interruptor de presión Presione para encender o apagar Balancín de atenuación Presione para aumentar la intensidad

Interruptor de presión Presione para encender o apagar

Presione para atenuar

FASS™ Frente Accesible Servicio Interruptor

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA y ) son marcas registradas, y RadioRA 2, Hi-lume 3D, Compact SE y FASS son marcas de Lutron Electronics Co., Inc. NEC es una marca registrada de la National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc.

FASS™ Frente Accesible Servicio Interruptor

-RD-277 o -RS-277 sólo OR OFF

ON

Retorno de los atenuadores / interruptores a la configuración de fábrica Nota: El retorno de un atenuador / interruptor a su configuración de fábrica lo removerá del sistema y borrará toda su programación. Paso 1: P  ulse tres veces y mantenga el interruptor de presión de un control. NO suelte el botón después del tercer pulso. Paso 2 : M  antenga presionado el interruptor después del tercer pulso (durante 3 segundos aproximadamente) hasta que los LEDs del atenuador se enciendan y apaguen rápidamente en secuencia, o el LED del interruptor parpadee rápidamente. Paso 3 : S  uelte el interruptor e inmediatamente púlselo otras tres veces. Los LEDs del atenuador se encenderán y apagarán lentamente en secuencia. El LED del interruptor parpadeará lentamente. El control volvió ahora a su configuración de fábrica y deberá ser reprogramado dentro de un sistema. Garantía: Para obtener información sobre la garantía, consulte la Garantía provista con el producto o visite http://www.lutron.com/TechnicalDocumentLibrary/HomeWorks_Warranty.pdf

Pour le Guide de configuration du système et outils requis, consulter le site www.lutron.com/radiora2 Spécifications de charge : Commande

-6D

Type de charge

Charge min.

Inc.

50 W

600 W

BTM2

50 W / VA

450 W /  600 VA

1

2

Inc./ BTE

5W

600 W

BTM

5 W / VA

450 W /  600 VA

Inc.

50 W

1 000 W

BTM2

50 W / VA

800 W /  1 000 VA

-6NA1 2

-10D1

Inc.

10 W

1 000 W

BTM2

10 W / VA

800 W /  1 000 VA

1

-10ND

-F6AN-DV3, 4, 5

-8ANS6

-8S-DV7, 8

Charge max.

Fluorescent/ DEL à trois (3) fils

0,05 A

6A

1 ballast

60 ballasts

Éclairage

10 W / VA

8A

Moteur

0,08 A

1/4 HP 5,8 A

Éclairage

40 W / VA

8A

Moteur

0,4 A

1/10 HP 3A

-RD9

Voir gradateur

-RS9

Voir commutateur

-RD-27710

Voir gradateur

-RS-27710

Voir commutateur

8,3 A

1 Type de charge pour gradateur : -6D, -10D et -10ND sont conçus seulement pour des charges installées en permanence, incandescentes, magnétiques à basse tension ou tungstène halogène.  -6NA est conçue seulement pour des charges installées en permanence, incandescentes, électroniques à basse tension, magnétiques à basse tension ou tungstène halogène.  Ne pas installer de gradateurs pour la commande de prises standards ou d’appareils motorisés. Ne mélangez pas les types de charge incandescente, halogène, BTM ou BTE sur un gradateur. 2  Applications à basse tension : Utilisez les gradateurs -6D, -10D et -10ND uniquement sur des charges à transformateur basse tension ferro-magnétique. Ne pas utiliser sur un transformateur électronique (à semi-conducteur).  Utiliser le gradateur -6NA sur des charges à contrôlables transformateur basse tension électronique (à semiconducteur) ou ferro-magnétique.  Le fonctionnement d’un circuit d’éclairage à basse tension ayant des ampoules hors d’usage ou non installées peut cause une surchauffe du transformateur et une défaillance prématurée. Lutron fait les recommandations suivantes : a. Ne pas utiliser les circuits à basse tension qui ne sont pas dotés de lampes en état de fonctionnement. b. Remplacer dès que possible les ampoules hors d’usage. c. Utiliser les transformateurs avec protection thermique ou enroulements primaires à fusible afin d’empêcher une défaillance causée par surintensité. 3 Type de charge pour gradateur fluorescent : Le gradateur -F6AN-DV est conçu pour utilisation avec ballasts de fluorescents ou pilotes de lampes à DEL raccordés en permanence sur un circuit 120 V~ ou 277 V~ à 3 fils. Utiliser seulement les appareils Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, or EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Ne PAS utiliser des ballasts ou pilotes différents avec ces produits. Ne pas installer pour le contrôle de prises de courant ou d’appareils motorisés. 4 Amplificateur de puissance / charge d’interfaces : -6NA, -10ND, -F6AN-DV, et -8ANS ne peut être utilisé pour contrôler amplificateur de puissance / charge d’interfaces. Pour connaître les types de amplificateur de puissance / charge d’interfaces compatibles voir Lutron P/N 369225. 5 Charge maximale : La charge maximale pour le gradateur -F6AN-DV est soit la puissance de charge déclassée soit le nombre de ballasts, selon le plus PETIT de ces deux nombres. 6 Type de charge pour commutateur -8ANS : La commande -8ANS est conçue pour une utilisation sur des charges installées en permanence, incandescentes, magnétiques à basse tension, electroniques à basse tension ou fluorescentes et charges motorisées jusqu’à 1/4 HP (5,8 A) fixes. 7 Type de charge pour commutateur -8S-DV : Le commutateur -8S-DV est conçu pour utilisation avec des charges motorisées, fluorescentes, incandescentes, à transformateur B.T. magnétique ou électronique raccordées en permanence sur une alimentation à 120 V~ ou avec charges fluorescentes ou à transformateur B.T. magnétique raccordées en permanence sur un circuit alimenté à 277 V~. 8  Condensateur shunt (inclus) : Certaines applications du commutateur -8S-DV peuvent nécessiter l’installation d’un condensateur shunt. Ceci est principalement requis pour les types de charges sensibles aux courants de fuite (par ex. ballasts fluorescentes). Si la charge scintille, installer un condensateur shunt. Pour l’installation d’un condensateur shunt, voir le Schéma de câblage 4 ou 8. 9  Gradateur/commutateur à distance à 120 V~ : Les gradateurs / commutateurs à distance -RD et -RS sont conçus pour utilisation avec des gradateurs/commutateurs à 120 V~. 10  Gradateur/commutateur à distance à 277 V~ : Les gradateurs / commutateurs à distance –RD-277 et – RS-277 sont conçus pour utilisation avec des gradateurs/ commutateurs à 277 V~. Ne PAS utiliser avec une charge motorisée.

Commande Gradateur

Commutateur Gradateur à distance

Commutateur à distance

-6D

Notes importantes AVERTISSEMENT – Danger d’enfermement – Pour éviter les dangers d'enfermement, de graves blessures ou le décès de personne, ces commandes ne doivent pas être utilisées pour contrôler des équipements qui ne sont pas visibles à partir de tous les emplacements de commande ou pouvant créer des situations dangereuses ou des pièges si elles sont actionnées accidentellement. Les équipements qui ne doivent pas être contrôlés par ces commandes comprennent (mais sans s’y limiter) : les barrières motorisées, les portes de garage, les portes industrielles, les fours à micro-onde, les coussins chauffants etc. Il est de la responsabilité de l’installateur de s’assurer que l’équipement commandé est visible à partir de tous les emplacements de commande et que seuls des équipements appropriés sont connectés à ces contrôles. Le non respect de cette règle peut causer des blessures graves ou fatales. Codes : Installer conformément à tous les codes électriques locaux et nationaux. Mise à la terre : Dans les cas où le boîtier mural ne possède aucun “ dispositif de raccordement de fils de terre ”, le code “ National Electrical Code® ” (NEC®) 2011 américain permet l’installation de contrôles de remplacement si : 1) une plaque frontale non métallique et ininflammable est utilisée et fixée par des vis non métalliques ou 2) le circuit est protégé par un disjoncteur de fuite de terre (GFCI). Lors de l’installation d’un contrôleur selon l’une des ces méthodes, placez un capuchon sur le fil vert (ou retirez-le) avant de monter le contrôleur dans le boîtier mural.

-6NA

-10D, -10ND

-F6AN-DV*

-8ANS

Type de charge

Charge min.

Charge max.

Incand.

500 W

400 W

BTM

400 W /  500 VA

300 W /  400 VA

Incand./ BTE

500 W

400 W

BTM

400 W /  500 VA

300 W /  400 VA

Incand.

800 W

650 W

BTM

600 W /  800 VA

500 W /  650 VA

Fluorescent/DEL à 3 fils

5A

3,5 A

50 ballasts

35 ballasts

Éclairage

6,5 A

5A

Moteur

1/4 HP 5,8 A

1/6 HP 4,4 A

Éclairage

8A (duplex) 7A (triple)

Moteur

1/10 HP 3A

-8S-DV

Environnement : Température ambiante de fonctionnement : 0 ºC à 40 °C (32 °F à 104 °F) 0 à 90% d’humidité sans condensation. Usage à l’intérieur seulement. Espacement : Pour installer une commande au-dessus d’une autre, laisser un espace vertical d’au moins 114 mm (4 ½ po) entre elles. Plaques murales : Les plaques murales Claro® et Satin Colors® de Lutron® sont recommandées pour obtenir le meilleur assortiment de couleurs et une apparence esthétique. Ne pas peindre les commandes ni les plaques murales. Nettoyage : Pour nettoyer, essuyer à l’aide d’un linge propre et humide. NE PAS utiliser de nettoyants chimiques. Plaques murales : Lutron recommande les boîtes murales de 89 mm (3 ½ po) de profondeur pour faciliter l’installation. Plusieurs commandes peuvent être regroupées dans une boîte à assemblage multiple. Voir Tableau de déclassement. Gradateurs/commutateurs à distance : Utiliser uniquement les gradateurs à distance (-RD/ -RD-277) et commutateurs à distance (-RS/-RS-277) avec les commutateurs/gradateurs. Un total de 9 -RD / -RD-277 ou -RS / -RS-277 peuvent être utilisés avec les gradateurs ou commutateurs. Les commutateurs mécaniques à trois ou quatre voies ne sont pas compatibles avec le système. Emplacement des dispositifs RF : Les gradateurs et commutateurs RF doivent être placés à moins de 9 m (30 pi) d’un répétiteur de signal RF. Les gradateurs/commutateurs à distance ne doivent pas être obligatoirement à une distance spécifique d’un répétiteur. Pour les systèmes avec un répétiteur de signal RF, les gradateurs/commutateurs RF ne peuvent pas être commandé par le système avant d’être programmés dans un système conformément au Guide de configuration de systèmes.

Assistance technique : É.U. / Canada : 1.800.523.9466 | Mexique : 001-888-235-2910 Brésil: +55 (11) 3257-6745 (Lundi-Vendredi 8:30 to 17:30 BRT) | Autres pays : +1.610.282.3800 24 heures par jour, 7 jours par semaine www.lutron.com

b. C  apuchons de connexion : Préparation des fils. Pour les connexions avec capuchon, se conformer aux longueurs de dénudage recommandées pour les combinaisons de fils utilisés avec les capuchons fournis. Remarque : Les capuchons de connexion fournis s’utilisent avec des fils de cuivre seulement. Capuchon de connexion •P  our les fils de calibre 1,5 mm2 (14 AWG) ou 2,5 mm2 (12 AWG), enlever l’isolant sur 10 mm (3/8 po). •P  our les fils de calibre 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG), enlever l’isolant sur 11 mm (7/16 po). •U  tiliser pour raccorder un ou deux fils 1,5 mm2 (14 AWG) ou 2,5 mm2 (12 AWG) avec un fil de calibre 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG)

7A

Note: Les commandes -8ANS, -RD-277 and -RS-277 ont des ailettes qui doivent être enlevées avant de faire une installation à jumelage multiple. Les commandes -6D, -6NA, -10D, -10ND, -F6AN-DV, -8S-DV, -RD and -RS n’ont pas d’ailette à enlever pour les installations à jumelage multiple. Ne pas retirer les ailettes extérieures aux extrémités de l’alignement de contrôles multiples

Les ailettes entre tous les contrôles

adjacents sont enlevées

Le contrôle du milieu de l’unité a ses ailettes latérales enlevées des deux côtés

Installation AVERTISSEMENT – Danger d’électrocution – Pour éviter les chocs électriques, Identifier et retirer le fusible ou verrouiller le disjoncteur en position Ouvert (OFF) avant de procéder. Effectuer le câblage sous tension peut entraîner des lésions corporelles graves, voire la mort. 1. C  ouper l’alimentation au niveau de la boîte à fusibles ou du disjoncteur. 2. A  vant d’installer le(s) contrôles, contrôler la présence de tout court-circuit. Après avoir coupé l’alimentation, installer les commutateurs mécaniques entre le fil sous tension et la charge et rétablir l’alimentation. Si les lumières ne s’allument pas ou qu’un disjoncteur se déclenche, vérifier et rendre le câblage conforme au schéma approprié et faire une nouvelle vérification. N’installer les contrôles qu’après avoir vérifié qu’il n’y a pas de court-circuit. La garantie sera annulée si une unité de contrôle est mise sous tension dans un circuit comportant un court-circuit. 3. Câbler les contrôles selon un des moyens décrits ci-après : a. B  ornes de raccordement : Couper ou dénuder les fils de la boîte murale à la longueur indiquée à la jauge de dénudage à l’endos du contrôle. • Bornes à pression : N’utiliser qu’avec des conducteurs de cuivre massif de calibre 1,5 mm2 (14 AWG). NE PAS utiliser de fil toronné ou torsadé. Insérer le conducteur jusqu’au fond de la borne. Pour dégager le fil, insérer un petit tournevis plat dans la fente sous la borne. et appliquer une pression en retirant le fil. OU

Laiton Sous tension Noir

Gradateur ou interrupteur

Bleu

1

Laiton Argent

Sous tension

Bleu

Noir

Vert

120 V~ 50/60 Hz

Guide

Installation1 d’un seul avec neutre -6NA, -10ND, et -8ANS (120 V~)

Commutateur

Mise à la terre

Neutre

1

Vert

120 V~ 50/60 Hz

Charge

Charge

Schéma de câblage 4

Installation1 d’un seul gradateur avec neutre -F6AN-DV (120/277 V~)

Installation1 d’un seul sans neutre -8S-DV avec condensateur shunt en option2 (120-277 V~)

Gradateur Bleu

Laiton Sous Argenté tension

Noir

1

Orange

Sans alimentation • Disjoncteur ouvert (OFF) ou déclenché. Vérifier la présence éventuelle de court-circuit. • L’interrupteur FASS™ est ouvert (position « OFF »). Vérifier le gradateur/ commutateur et toutes les télécommandes gradateur/commutateur. Voir Remplacement de tubes/ampoules. Câblage • Fils court-circuités. S’assurer que la borne bleue n’est pas mise à la terre ou court-circuitée à d’autres fils. • Erreur de câblage. S’assurer que le câblage est conforme aux directives d’installation et aux schémas de câblage. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge.

Orange

Blanc

Noir Vert

120/277 V~ 50/60 Hz

Noir Orange

Mise à la terre

Blanc

Neutre

Commutateur Laiton

Bleu

Sous tension

Noir

Optionnel

Vert

120-277V~ 50/60 Hz

La charge est en dessous de la charge minimale exigée • S’assurer que la charge connectée est conforme aux exigences minimales pour cette commande. Voir les Spécifications de charge. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge.

1

Condensateur shunt2

Charge Mise à la terre

Ampoules brûlées ou absentes • Remplacer ou installer les ampoules.

Neutre

Schéma de câblage 5

Ampoules à diodes • Si des ampoules à diodes sont utilisées, les remplacer par des ampoules d’un autre type.

Installation3 à emplacements multiples sans neutre Gradateur -6D, -10D with -RD (120 V~) Gradateur à distance / gradateur3

Gradateur3 / gradateur à distance

Gradateur à distance / gradateur3

Bleu

Laiton

Noir

Vert

Bleu

Laiton

Bleu

Noir

Vert

Remarque : Le gradateur peut être installé à n’importe quel emplacement dans le circuit.

Vert

Charge Mise à la terre

Mise à la terre

Mise à la terre

Neutre

4. R  epousser tous les fils dans le boîtier mural et visser légèrement le contrôle au boîtier à l’aide des vis de montage fournies. Ne pas coincer les fils. 5. Attacher l’adaptateur de la plaque murale et la plaque murale Claro® ou Satin Colors® de Lutron®. Voir le Schéma d’assemblage. a. Installer l’adaptateur de la plaque murale sur le devant du/des contrôle(s). b. Serrer les vis de montage du contrôle jusqu’à ce que l’adaptateur du boîtier mural soit à égalité du mur (ne pas trop serrer). c. Enclencher la plaque murale sur l’adaptateur et s’assurer que le contrôle est bien aligné. d. Si les contrôles sont mal alignés, desserrer les vis de montage en conséquence. 6. Rétablir l’alimentation. Vérifier si le fonctionnement local est correct. Voir la feuille de Fonctionnement du gradateur ou Fonctionnement du commutateur.

Cause probable et action suggérée

Les lumières ne répondent pas à l’actionnement du bouton tactile du gradateur/ commutateur ou de la télécommande gradateur/ commutateur

Mise à la terre

Schéma de câblage 3

120 V~ 50/60 Hz

Pour installation d’une unique et à multiples : Voir Schémas de Câblage.

de dépannage

Symptôme

Neutre

Laiton Sous tension Noir

Visser fermement le capuchon de connexion

*La charge maximale pour le gradateur -F6AN-DV est soit la puissance de charge déclassée ou le nombre de ballasts, selon le plus PETIT des deux nombres.

Connexion au fil de neutre : Les gradateurs -6NA, -10ND, -8ANS et -F6AN-DV requièrent une connexion au fil neutre du boîte murale où les gradateur/interrupteur doivent être installés. Si un fil neutre n’est pas présent dans le boîte murale, contacter un électricien certifié pour modifier l’installation.

*Conditions typiques d’essai de consommation d’énergie : G  radateur / commutateur : la charge est coupée et le mode éclairage nocturne est activé. G  radateur / commutateur à distance : la charge est coupée.

Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-301 Rev. B 02 / 2012

Dans les installations à jumelage multiple, plusieurs commandes sont regroupées horizontalement dans un boîtier mural à jumelage multiple. Lorsque des commandes sont regroupées dans un boîtier mural, le déclassement est requis. Ceci ne s’applique pas aux gradateurs/commutateurs à distance. Tableau de déclassement

Schéma de câblage 2

Installation1 d’un seul sans neutre Commutateur -6D, -10D (120 V~)

La charge scintillent ou bouton tactile ne fonctionne pas, même si la charge est supérieure à 40 W (-8S-DV seulement)

Courant de fuite • Installer un condensateur shunt. Voir le Schéma de câblage 4 ou 8.

Les lumières s’allument et s’éteignent sans arrêt ou à l’actionnement du bouton tactile, les lumières s’allument et puis s’éteignent

La charge est de puissance inférieure au minimum requis • Augmenter la charge au-dessus du minimum requis pour ce contrôle. Voir Spécifications de charge. • Pour le commutateur -8S-DV, ajouter un condensateur shunt. Voir le Schéma de câblage 4 ou 8. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge.

La charge scintillent (-8S-DV seulement)

La charge est de puissance inférieure au minimum requis • Augmenter la charge au-dessus du minimum requis pour ce contrôle. Voir Spécifications de charge. • Installer un condensateur shunt. Voir le Schéma de câblage 4 ou 8.

Un pavé numérique ne peut ALLUMER/ÉTEINDRE les lumières

Programmation inadéquate • Programmer conformément au Guide de configuration du système.

Schéma de câblage 6

Installation3 à emplacements multiples avec neutre4 -6NA et -10ND avec RD-RD, -8ANS avec RD-RS (120 V~) Gradateur à distance ou interrupteur à distance

Laiton

Sous tension

Bleu

Noir

Laiton

Gradateur ou interrupteur

Bleu

Noir

Vert

120 V~ 50/60 Hz

Remarque : Le gradateur/interrupteur principal doit être raccordé à la charge.

Gradateur à distance ou interrupteur à distance

Laiton Argent

Noir

Vert

Mise à la terre

Bleu

Vert

Mise à la terre

Charge

Mise à la terre

Neutre

Installation3 de gradateurs à emplacements multiples avec neutre4 Gradateur -F6AN-DV avec gradateur à distance -RD ou -RD-277 (120/277 V~) Gradateur à distance

Sous tension

Laiton/ Rouge

Bleu

Gradateur à distance Laiton/ Rouge

Laiton

Bleu

Argenté Noir

120/277 V~ 50/60 Hz

Noir Vert

Remarque : Le gradateur principal doit être raccordé à la charge.

Gradateur

Bleu Orange

Noir Orange Blanc

Noir Vert

Vert Noir

Mise à la terre

Mise à la terre

Mise à la terre

Orange Blanc

Neutre

Hors de la portée RF • Rapprocher à moins de 9 m (30 pi) d’un répétiteur de signal RF. Câblage • Fils court-circuités. S’assurer que la borne bleue n’est pas mise à la terre ou court-circuitée à d’autres fils. • Erreur de câblage. S’assurer que le câblage est conforme aux directives d’installation et aux schémas de câblage.

Schéma de câblage 7

Ballast/pilote de lampe à diodes Lutron®

Gradateur : R  RD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) Commutateur : R  RD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz Consommation de puissance typique* : 0.6 W

Schéma de câblage 1

La plaque murale est chaude

Dissipation de la commande à semi-conducteurs • Les gradateurs/commutateurs à semi-conducteurs dissipent à l’intérieur environ 2 % de la charge totale raccordée. Il est normal qu’ils soient chauds au toucher lorsqu’ils sont en service.

Remarque : Pour des suggestions additionnelles de dépistage de défauts, se référer au Guide de configuration.

Ballast/pilote de lampe à diodes Lutron®

Gradateurs style décorateur Maestro RF®

Gradateurs à distance : RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Commutateurs à distance : RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) Consommation de puissance typique* : 0 W

• Bornes à vis : N’utiliser qu’avec des conducteurs de cuivre massif de calibre 2,5 mm2 (12 AWG) ou 1,5 mm2 (14 AWG). NE PAS utiliser de fil multibrins ou toronné. Enrouler le conducteur sous la tête de la vis de la borne. Serrer au couple de 0,55 N•m (5 lb-po).

Ballast/pilote de lampe à diodes Lutron®

Installations à jumelage multiple

Veuillez lire avant l’installation

Ballast/pilote de lampe à diodes Lutron®

Français Directives d’installation

Schéma de câblage 8 Schéma d’assemblage

Adaptateur Plaque Vis de de plaque murale montage murale Vis de des montage de contrôles l’adaptateur

Installation3 à emplacements multiples sans neutre Commutateur -8S-DV avec commutateur à distance -RS ou -RS-277 et condensateur shunt en option2 (120-277 V~) Commutateur à distance / commutateur3 Laiton/ Rouge

Sous tension

Noir

Boîtier mural

Inclus :

120-277 V~ 50/60 Hz

Commande

Capuchons de connexion (1 ou 5) Vis de montage (2)

Adaptateur de plaque murale et plaque murale vendus séparément.

Remplacement de tubes/ ampoules AVERTISSEMENT – Danger d’électrocution – Pour toute autre procédure que le simple remplacement des tubes/ampoules, l’alimentation doit être coupée au panneau de distribution. Effectuer tout travail avec le système sous tension peut entraîner des lésions corporelles graves, voire la mort. Pour remplacer les tubes/ampoules sans danger, couper l’alimentation des appareils d’éclairage en plaçant l’interrupteur FASSTM du gradateur/commutateur et de tous les gradateurs/commutateurs à distance en position OFF.

Commutateur à distance / Commutateur3 / commutateur à distance commutateur3 Laiton/ Rouge

Bleu

Vert

Noir

Bleu

Laiton/ Rouge

Vert

Bleu

Noir

Remarque : Le commutateur peut être installé à n’importe quel emplacement dans le circuit.

Optionnel

Vert

Condensateur shunt2

Charge Mise à la terre

Mise à la terre

Mise à la terre

Neutre

1P  our les installations à un seul emplacement de commande, serrer la borne bleue sans y relier de fil. NE connecter aucun des fils, ou fil de m.a.l.t. à la borne bleue. 2 Le condensateur shunt doit être installé à l’intérieur du boîtier de l’appareil d’éclairage ou dans un boîtier de jonction séparé. 3 Installer un (1) seulement gradateur/commutateur par circuit. Un circuit de gradateur/commutateur peut comprendre jusqu’à 9 contrôles gradateur/commutateur à distance. La longueur permise du fil bleu est de 76 m (250 pi). 4 Les gradateurs/interrupteurs avec fil neutre doivent être connectés du côté charge d’une installation à emplacement multiple.

Fonctionnement du gradateur Fonctionnement du Voyants d’état (-F6AN-DV seulement) commutateur Indique le niveau d’éclairage et émet une lueur discrète de veilleuse lorsque la charge est coupée Bouton touche Toucher pour allumer/éteindre

Voyant d’état (-8S-DV seulement) Indique l’état de l’appareil d’éclairage et émet une lueur discrète de veilleuse lorsque la charge est coupée

Bouton d’actionnement à bascule du gradateur Appuyer pour augmenter l’éclairage. Appuyer pour atténuer l’éclairage.

FASS™ Interrupteur de Service à Accès Frontal

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, et ) sont des marques de commerce déposées et RadioRA 2, Hi-lume 3D, Compact SE et FASS sont des marques de commerce de Lutron Electronics Co., Inc. NEC est une marque de commerce déposée de National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc.

Rappel des réglages d’usine des gradateurs/commutateurs

Bouton touche Toucher pour allumer/éteindre

FASS™ Interrupteur de Service à Accès Frontal

-RD-277 ou -RS-277 seulement OR OFF

ON

Remarque : Le rappel du gradateur/commutateur à ses réglages d’usine le retirera du système et effacera toute sa programmation. Étape 1 : T  aper trois fois du doigt sur le bouton tactile d’un contrôle et garder le doigt appuyé sur le bouton après la troisième tape. Étape 2 : G  arder le bouton appuyé durant environ 3 secondes, jusqu’à ce que les voyants du gradateur débutent une séquence d’illumination de va-et-vient rapide ou que le voyant DEL du commutateur se mette à clignoter rapidement Étape 3 : R  elâcher le bouton et refaire immédiatement trois tapes rapides sur le bouton. Les voyants du gradateur débuteront une séquence d’illumination de va-et-vient lente. Le voyant DEL du commutateur clignotera lentement. Le contrôle est alors remis à ses réglages d’usine et doit être reprogrammé dans le système. Garantie : Pour information sur la garantie, veuillez voir la garantie incluse avec le produit, ou visitez http://www.lutron.com/TechnicalDocumentLibrary/HomeWorks_Warranty.pdf

Português

Ao combinar dimmers / interruptores em uma caixa de embutir, é preciso reduzir a carga. Isso não é necessário para interruptores /dimmers remotos. Tabela de redução de carga

Para o Guia de configuração do sistema e ferramentas, visite: www.lutron.com/radiora2

Controle

Especificações de carga: Controle

-6D1

Tipo de carga

Carga mín.

Carga máx.

Incand.

50 W

600 W

Notas importantes

BTM

50 W / VA

450 W /  600 VA

Incand./ BTE2

5W

600 W

AVISO – Perigo de imobilização – Para evitar o risco de imobilização, ferimentos graves ou morte, estes controles não devem ser usados para controlar equipamentos que não estão visíveis a partir de todos os locais de controle ou que podem criar situações perigosas, como imobilização, caso seja operado acidentalmente. Exemplos de equipamentos que não devem ser operados por estes controles incluem (mas não se limitam a) portões motorizados, portões de garagem, portões industriais, fornos de microondas, etc. É de responsabilidade de quem instala garantir que o equipamento que está sendo controlado esteja visível de cada local de controle e que somente equipamentos adequados sejam conectados a estes controles. Proceder de maneira contrária poderá causar morte ou ferimentos graves.

2

1

-6NA

BTM2 Incand. -10D1

1 000 W

BTM

50 W / VA

800 W /  1 000 VA

Incand.

10 W

1 000 W

BTM

10 W / VA

800 W /  1 000 VA

Fluorescente / LED de 3 fios

0,05 A

6A

1 balastro

60 balastros

Iluminação

10 W / VA

8A

2

-F6AN-DV3, 4, 5

-8ANS6

Motor Iluminação

-8S-DV7, 8 -RD9

450 W /  600 VA

50 W

2

-10ND1

5 W / VA

Motor

0,08 A 40 W / VA 0,4 A

1/4 HP 5,8 A 8A 1/10 HP 3A

Consulte dimmer

9

-RS

Consulte interruptor

-RD-27710

Consulte dimmer

10

-RS-277

8,3 A

Consulte interruptor

1 Tipo de carga de dimmer: Os controles -6D, -10D e -10ND só devem ser utilizados com cargas incandescentes, magnéticas de baixa tensão ou de tungstênio-halogênio instaladas permanentemente.  O controle -6NA só deve ser utilizado com cargas incandescentes, eletrônicos de baixa tensão, magnéticas de baixa tensão ou de tungstênio-halogênio instaladas permanentemente.  Não instale dimmers para comandar tomadas ou aparelhos motorizados. Não é permitido misturar tipos de carga incandescente, halogênio, BTM ou BTE em um dimmer. 2 Aplicações de baixa tensão: Use os modelos -6D, -10D e -10ND somente com transformadores magnéticos (núcleo e bobina) de baixa tensão. Não devem ser utilizados com transformadores eletrônicos (transistorizados) de baixa tensão.  Use o modelo -6NA com dimerizáveis transformadores eletrônicos (transistorizados) ou magnéticos (núcleo e bobina) de baixa tensão.  El funcionamiento de un circuito de bajo voltaje sin lámparas o con lámparas que no funcionan puede resultar en el sobrecalentamiento del transformador y fallas prematuras. Lutron recomienda firmemente lo siguiente: a. Não use circuitos de baixa tensão sem lâmpadas boas. b. S  ubstitua lâmpadas as queimadas o mais rápido possível. c. Use transformadores com proteção térmica ou enrolamentos primários com fusível para evitar falhas devido a sobrecorrentes. 3 Dimmer de carga tipo fluorescente: -F6AN-DV foi projetado para uso com controles de balastros fluorescentes ou comandos de LEDs com voltagem de linha de 120 V~ ou 227 V~ de três cabos instalados permanentemente. Use somente com Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, ou EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). NÃO use com qualquer outro balastrobalastro ou comando. Não instale para controlar receptáculos ou aplicações operadas por motor. 4 Amplificador de potência – interfaces de carga: -6NA, -10ND, -F6AN-DV, e -8ANS pode ser usado para controlar amplificador de potência – interfaces de carga. Para obter uma lista de amplificador de potência – interfaces de carga compatíveis consulte Lutron P/N 369225. 5 Carga máxima: A caga máxima para o -F6AN-DV é a carga reduzida ou o número de balastros, o que for MENOR. 6 Tipo de carga do interruptor -8ANS: -8ANS é um tipo projetados para uso com todas as cargas incandescentes, magnéticas de baixa tensão, eletrônicos de baixa tensão ou de fluorescentes instaladas permanentemente e com cargas de motor de até 1/4 HP (5,8 A). 7 Tipo de carga do interruptor -8S-DV: -8S-DV foi projetado para uso com cargas incandescentes permanentemente instaladas de 120 V~, baixa voltagem magnética, baixa voltagem eletrônica ou cargas de motores; ou cargas fluorescentes ou baixa voltagem magnética de 277 V~. 8 Condensador Shunt (incluído): Algumas instalações do -8S-DV podem exigir o uso de um condensador shunt. Isto é necessário para tipos de cargas sensíveis à corrente de fuga (ou seja, balastros fluorescentes). Se carga tremula, instale um condensador shunt. Para a instalação do condensador shunt, consulte o Esquema de ligações elétricas 4 ou 8. 9  Dimmer / interruptor remoto 120 V~: -RD e -RS foram projetados para uso com dimmers / interruptores 120 V~. 10  Dimmer / interruptor remoto 277 V~: -RD-277 e -RS-277 foram projetados para uso com dimmers/ interruptores 277 V~. NÃO use com cargas de motor.

Interruptor

Dimmer remoto

Interruptor remoto

Dimmer

Códigos: Instale de acordo com os códigos elétricos locais e nacionais. Aterramento: Se não houver uma “forma de aterramento” dentro da caixa de embutir, o Código Nacional de Eletricidade de 2011 (2011 National Electrical Code ® - NEC ®) permite que um controle seja instalado como um substituto, se 1) um espelho não metálico e não combustível for usado com parafusos não metálicos ou 2) o circuito for protegido por um interruptor diferencial por falha no aterramento (GFCI). Ao instalar um controle de acordo com esses métodos, tampe ou remova o fio verde antes de parafusar o controle na caixa de embutir.

-6D

-6NA

-10D, -10ND

-F6AN-DV*

-8ANS

Tipo de carga

Extremo final do agrupamento

Meio do agrupamento

Incand.

500 W

400 W

BTM

400 W /  500 VA

300 W /  400 VA

Incand./ BTE

Espaçamento: Se for instalar um controle sobre o outro, mantenha um espaço vertical entre eles de pelo menos 114 mm (4 ½ in). Espelhos: os modelos Lutron® Claro® e Satin Colors® são recomendados pela variedade de cores e pelo design. Não pinte os controles ou espelhos. Limpeza: Para limpar, passe um pano limpo úmido. NÃO use qualquer solução química de limpeza. Caixa de embutir: A Lutron recomenda o uso de caixas com 89 mm (3 ½ in) de profundidade para facilitar a instalação. É possível instalar vários controles em uma mesma caixa de instalação embutida. Consulte o Tabela de redução de carga. Dimmers / interruptores remotos: Use somente dimmers remotos (-RD / -RD-277) e interruptores remotos (-RS / -RS-277) com dimmers / interruptores. Podem ser usados até 9 -RD / -RD-277 or -RS / -RS-277 com dimmers ou interruptores. Interruptores mecânicos de 3 ou 4 vias não funcionarão. Localização dos dispositivos de RF: Os dimmers / interruptores de RF devem estar a uma distância máxima de 9 m (30 pés) de um repetidor de sinal de RF. Os interruptores / dimmers remotos não precisam estar dentro de limites específicos em relação a um repetidor. Para sistemas com repetidor de sinal de RF, os dimmers / interruptores de RF não podem ser controlados pelo sistema enquanto não estiverem programados de acordo com o Guia de configuração do sistema.

*Condições de teste de consumo normal de energia: D  immer / interruptor: carga desligada, modo luz noturna habilitado. Dimmer / interruptor remoto: carga desligada.

400 W

BTM

400 W /  500 VA

300 W /  400 VA

Incand.

800 W

650 W

BTM

600 W /  800 VA

500 W /  650 VA

5A

3,5 A

Fluorescente / LED de 3 fios.

50 balastros

35 balastros

Iluminação

6,5 A

5A

Motor

1/4 HP 5,8 A

1/6 HP 4,4 A

Iluminação

8A (2-grupos) 7A (3-grupos)

-8S-DV

7A

*A caga máxima para o -F6AN-DV é a carga reduzida ou o número de balastros, o que for MENOR.

Note: -8ANS, -RD-277 and -RS-277 possuem aletas que precisam ser removidas para instalações multigrupos. -6D, -6NA, -10D, -10ND, -F6AN-DV, -8S-DV, -RD and -RS não possuem abas que precisam ser removidas. Não remova as abas externas nos controles na extremidade do grupo.

Cada controle teve as abas internas removidas

Nota: Os conectores de cabo fornecidos são adequados somente para cabos de cobre. Conector de cabo: •R  emova 10 mm (3/8 pol) de isolante do fio 1,5 mm2 (14 AWG) ou do fio 2,5 mm2 (12 AWG). • Remova 11 mm (7/16 pol) de isolante do fio 0,75 mm2 (18 AWG) ou do fio 1,0 mm2 (16 AWG). •U  se para unir um ou dois cabos 1,5 mm2 (14 AWG) ou 2,5 mm2 (12 AWG) com um cabo 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG).

O controle no meio do grupo está com todas as abas removidas

Instalação ATENÇÃO – Risco de choques – Para evitar o risco de choques elétricos, localize e remova o fusível ou trave o disjuntor na posição OFF (desligado) antes de prosseguir. Fazer instalação com a chave geral ligada pode resultar em lesões graves ou fatais. 1. D  ESLIGUE a alimentação na caixa de fusível ou no disjuntor. 2. Verifique a instalação quanto a curtoscircuitos antes de instalar o(s) controle(s). Com a alimentação DELSIGADA, instale interruptores mecânicos padrão entre quente e a carga. Restabeleça a alimentação. Se as lâmpadas não funcionarem ou o disjuntor for desarmado, verifique a fiação. Corrija a fiação e verifique novamente. Instale os controles somente quando não houver curtos-circuitos. A garantia é invalidada se o controle foi acionado (ON) havendo um curto-circuito. 3. Conecte os cabos de acordo com uma das opções abaixo: a. T  erminais: Apare ou retire o isolamento dos fios da caixa de embutir no comprimento indicado pelo medidor de corte, na parte posterior do controle. • Terminais a pressão: Use apenas com o fio 1,5 mm2 (14 AWG) de cobre sólido. NÃO use cabos trançados ou torcidos. Insira os cabos completamente. Para soltar um cabo, insira uma chave de fenda pequena na ranhura abaixo do terminal a pressão. Pressione a chave de fenda enquanto puxa o cabo para fora. OU

Esquema de ligações 2

Instalação1 em um único local sem neutro -6D, -10D (120 V~)

Instalação1 em um único local com neutro -6NA, -10ND e -8ANS (120 V~)

Interruptor

Latão

Latão Prata

Vivo Preto

Azul1

Preto

Verde

Verde

120 V~ 50/60 Hz

Carga Terra

Neutro

Sintoma

Causa provável e ação

As luzes não ACENDEM/ APAGAM quando a chave seletora no dimmer / interruptor ou dimmer / interruptor remoto é pressionada

Não há alimentação. • Disjuntor DESLIGADO ou aberto. Verifique se há curtos-circuitos. • FASS™ está na posição OFF. Mude FASS™ para a posição ON. Verifique o dimmer / interruptor, bem como todos os dimmers / interruptores remotos Consulte Substituição da lâmpada. Fiação • Cabos em curto. Verifique se o terminal azul não está conectado ao terra ou em curto com algum outro cabo. • Erro na fiação. Verifique se a fiação está de acordo com as instruções de instalação e os diagramas de conexão. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga.

Carga

Terra

Neutro

Esquema de ligações 3

Esquema de ligações 4

1

Dimmer

Preto

Azul1

Latão Prata

Vivo

Laranja

Laranja

Preto

Branco

Verde

120/277 V~ 50/60 Hz

Interruptor Latão

Azul1

Lâmpadas estão queimadas ou não estão instaladas • Substitua ou instale as lâmpadas.

Vivo Preto

Preto Laranja

Terra

Branco

Neutro

Opcional

Verde

120-277 V~ 50/60 Hz

3

Instalação em vários locais sem neutro -6D, -10D with -RD (120 V~)

Latão

3

Dimmer remoto / 3 dimmer

Latão

Azul

Dimmer / dimmer remoto Nota: O dimmer pode ser instalado em qualquer lugar do circuito.

Latão

Azul

Lâmpadas de diodo • Se estiverem sendo usadas lâmpadas de diodo, substitua-as por lâmpadas sem diodo

Condensador Shunt2

Carga Terra

Esquema de ligações 5 Dimmer remoto / 3 dimmer

A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima do controle. Consulte o Especificações de carga. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga.

Instalação1 em um único local sem neutro -8S-DV com condensador shunt opcional2 (120-277 V~)

Instalação em um único local com neutro -F6AN-DV (120/277 V~)

Azul

A carga tremula ou chave seletora não funciona, mesmo se a carga for superior a 40 W (somente -8S-DV)

Corrente de fuga • Instale um condensador shunt. Consulte o Esquema de ligações elétricas 4 ou 8.

A luz acende e apaga continuamente ou a luz acende (ON) quando a chave seletora é pressionada, apagando em seguida (OFF)

A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima de carga. Consulte as Especificações de carga. • Instale um condensador shunt com o -8S-DV. Consulte o Esquema de ligações elétricas 4 ou 8. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga.

A carga tremula (somente -8S-DV)

A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima de carga. Consulte as Especificações de carga. • Instale um condensador shunt. Consulte o Esquema de ligações elétricas 4 ou 8.

As luzes não acendem/ apagam a partir de um teclado

Programação incorreta • Programe de acordo com o Guia de configuração do sistema.

Vivo Preto

Instalação em um só local ou vários locais: consulte os Esquema de ligações. 4. C  oloque os cabos de volta na caixa de embutir e parafuse, sem apertar, o controle na caixa usando os parafusos fornecidos. Não amasse os cabos. 5. Prenda o adaptador de espelho e o espelho Claro® ou Satin Colors® da Lutron®. Consulte o Diagrama de montagem. a. Instale o adaptador do espelho na frente do(s) controle(s). b. Aperte os parafusos de montagem do controle até que adaptador do espelho fique rente à parede (não aperte demais). c. Encaixe o espelho no adaptador e verifique se o controle está alinhado corretamente. d. Se os controles estiverem desalinhados, afrouxe os parafusos de montagem apropriadamente 6. Restabeleça a alimentação. Verifique se a operação local está correta. Consulte a Operação do dimmer ou Operação do interruptor.

Diagrama de montagem Adaptador Espelho do espelho Parafusos de Parafusos de instalação do montagem do controle adaptador

Verde

120 V~ 50/60 Hz

Preto

Verde

Preto

Verde

Carga Terra

Terra

Terra

Neutro

Esquema de ligações 6 Instalação3 em vários locais com neutro4 -6NA e -10ND com RD-RD, -8ANS com RD-RS (120 V~) Dimmer remoto ou interruptor remoto

Dimmer remoto ou interruptor remoto

Latão

Latão

Azul

Nota: O dimmer deve ser instalado no lado da carga do circuito. Dimmer ou interruptor

Latão

Azul

Azul

Preto

Preto

Verde

120 V~ 50/60 Hz

Preto

Verde

Terra

Verde

Terra

Carga

Terra

O espelho está quente

Neutro

Esquema de ligações 7 Instalação3 do interruptor em vários locais com neutro -F6AN-DV com -RD ou -RD-277 (120/277 V~) Dimmer remoto Latão/ Vermelho

Dimmer remoto

Azul

Latão/ Vermelho

Azul

Preto 120/277 V~ 50/60 Hz

Nota: Consulteo Guia de configuração do sistema para outras sugestões de solução de problemas.

Azul

Latão Prata

Preto

Laranja

Preto Laranja Branco

Preto

Verde

Verde

Verde

Terra

Terra

Terra

Preto Laranja Branco

Neutro

Esquema de ligações 8

Modelo: MRF2-3BRL-L

Instalação3 do interruptor em vários locais sem neutro -8S-DV com -RS ou -RS-277 e condensador shunt opcional2 (120-277 V~) Interruptor remoto / 3 interruptor

Caixa de embutir

Incluído:

Latão/ Vermelho

Controle

Conectores de cabos (1 ou 5) Parafusos de instalação (2)

Adaptador do espelho e espelho vendidos separadamente.

Interruptor remoto / 3 interruptor Latão/ Vermelho

Azul

Azul

120-277 V~ 50/60 Hz

Verde

Preto

Verde

Latão/ Vermelho

Nota: O interruptor pode ser instalado em qualquer lugar do circuito.

(01) 07898525200097

Azul

Preto

Opcional

Verde

Condensador Shunt2

Carga Terra

Terra

Terra

Substituição de lâmpada

Neutro

AVISO – Perigo de choque – No caso de qualquer procedimento que não seja a troca rotineira de lâmpadas, o painel elétrico principal deverá estar desconectado da rede elétrica. Trabalhar com a rede ligada pode resultar em lesões graves ou fatais. Para sua segurança no caso de troca rotineira de lâmpadas, desligue a(s) luminária(s) movendo o interruptor FASSTM do dimmer / interruptor e de todos os interruptores / dimmers remotos para a posição OFF (desligado).

1A  o usar controles em instalações de único local, aperte o terminal azul sem nenhum fio conectado. NÃO conecte o terminal azul a nenhum outro fio nem ao terra. 2 O condensador shunt deve ser instalado no lado da luminária de carga ou em uma caixa J separada.

Este equipamento opera em caráter (01) secundário, 07898525200110 Modelo: RRD-F6AN-DV isto é, não tem direito à proteção contra interferência prejudicial, mesmo de estaçoes do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Modelo: RRD-6D

3 Instalação apenas um (1) dimmer / interruptor por circuito. Podem ser conectados no dimmer / interruptor até 9 dimmers / interruptores remotos. O comprimento total do cabo do terminal azul pode chegar a 76 m (250 pés). 4 Os dimmers/interruptores de fio neutro devem ser conectados no lado da carga da instalação em vários locais.

Operação do dimmer

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, e ) são marcas registradas e RadioRA 2, Hi-lume 3D, Compact SE e FASS são marcas registradass da Lutron Electronics Co., Inc. NEC é marca registrada da National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Brasil Ltda.

Operação do interruptor

LEDs de status (somente -F6AN-DV) Indica a intensidade da luz; tem um brilho leve, como uma iluminação noturna, quando a carga está desligada Chave seletora Toque para ligar/desligar Controle de atenuação Pressione para aumentar a intensidade Pressione para reduzir a intensidade

FASS™ Frente Acessível Serviço Interruptor

0839-11-6852 0145-11-0905

Modelo: RRD-10ND

3

Interruptor / Interruptor remoto

Vivo Preto

Dissipação de controle de estado sólido • Os dimmers / interruptores de estado sólido dissipam internamente cerca de 2% da carga total conectada. É normal que os dimmers / interruptores fiquem quentes durante o funcionamento.

Nota: O dimmer deve ser instalado no lado da carga do circuito.

Dimmer

Vivo

Fora da faixa de RF • Reposicione para estar dentro de um raio de 9 m (30 pés) de um repetidor de sinais de RF. Fiação • Cabos em curto. Verifique se o terminal azul não está conectado ao terra ou em curto com algum outro cabo. • Erro na fiação. Verifique se a fiação está de acordo com as instruções de instalação e os diagramas de conexão.

Prata

Vivo

Assistência técnica: Brasil: +55 (11) 3257-6745 (Segunda-feira–Sexta-feira 8:30 to 17:30 BRT) E.U.A. / Canadá: 1.800.523.9466 | México: +1.888.235.2910 | Outros países: +1.610.282.3800 24 horas por dia, 7 dias por semana www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-301 Rev. B 02 / 2012

Azul1

120 V~ 50/60 Hz

Guia para Resolução de problemas

Dimmer ou Interruptor

Vivo

Gire com firmeza o conector de fiação

1/10 HP 3A

Motor

Neutro: Os modelos -6NA, -10ND, -8ANS e -F6AN-DV exigem um condutor neutro na caixa de embutir, onde devem ser instalados o dimmer/ interruptor. Se não houver um condutor neutro na caixa de embutir, procure um eletricista autorizado para instalá-lo. Ambiente: Temperatura ambiente de trabalho: 0 °C a 40 °C (32 °F to 104 °F), 0% a 90% de umidade, sem condensação. Uso somente interior.

500 W



Esquema de ligações 1

Comando da Lutron® do balastro/LED

Dimmer: R  RD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) Interruptor: R  RD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz) Consumo normal de energia*: 0,6 W

• Terminais parafusados: Use apenas com o fio 2,5 mm2 (12 AWG) ou 1,5 mm2 (14 AWG) de cobre sólido. NÃO use cabos trançados ou torcidos. Enrole o cabo em volta do terminal parafusado. Aperte bem com 0,55 N•m (5 pol-lb). b. C  onectores de cabos: Prepare os cabos. Ao fazer conexões de cabos, siga o comprimento recomendado de desencape e as combinações para os conectores de cabo fornecidos

Comando da Lutron® do balastro/LED

Tipo Designer RF Maestro®

Em instalações multigrupos, vários controles são reunidos horizontalmente em uma mesma caixa de embutir.

Dimmers remotos: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Interruptores remotos: RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) Consumo típico de energia*: 0 W

Comando da Lutron® do balastro/LED

Por favor, leia antes de instalar

Comando da Lutron® do balastro/LED

Multigang Installations

Instruções de instalação

0839-11-6852

(01) 07898525200073 Modelo: RRD-10D

0839-11-6852

(01) 07898525200080

3283-10-0905

(01) 07898525200219

Modelo: RRD-8ANS

0839-11-6852

(01) 07898525200103 2854-10-0905 Modelo: RRD-8S-DV

(01) 07898525200189

LED de status (somente -8S-DV) Indica o status da luz; tem um brilho suave, como uma iluminação noturna, quando a carga está desligada Chave seletora Toque para ligar/desligar

FASS™ Frente Acessível Serviço Interruptor

-RD-277 ou -RS-277 apenas OR OFF

ON

Restauração dos dimmers/interruptores para a configuração de fábrica

Nota: A restauração de um dimmer / interruptor para a configuração de fábrica o removerá do sistema e apagará toda a programação Passo 1: T  oque três vezes na chave seletora de um controle. NÃO solte após o terceiro toque. Passo 2: M  antenha a chave seletora pressionada após o terceiro toque (por aproximadamente 3 segundos) até que os LEDs no dimmer comecem a piscar em sequência para cima e para baixo rapidamente ou o LED no interruptor pisque rapidamente. Passo 3: S  olte a chave seletora e, imediatamente, pressione-a três vezes novamente. Os LEDs no dimmer se deslocarão para cima e para baixo lentamente. O LED no interruptor piscará lentamente. O controle agora retornou à configuração de fábrica e precisa ser programado para um sistema.

* Fan Speed Control: RRD-2ANF (120 V~ 50 / 60 Hz) * Remote Dimmers: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz)

* Remote Switches: RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz)

Derating Chart

For system Setup Guide and tools visit www.lutron.com/radiora2

Control

Load Specifications Control

-6D1

1

-6NA

Load Type

Min. Load

Max. Load

Incand.

50 W

600 W

MLV2

50 W / VA

450 W /  600 VA

Incand./ ELV2

5W

600 W

MLV2

5 W / VA

450 W /  600 VA

Incand.

-10D1

MLV

-10ND1 -F6AN-DV3, 4, 5 -2ANF6 7

-8ANS

-8S-DV8, 9

2

10 W

1000 W

10 W / VA

800 W /  1000 VA

3-wire Fluorescent/ LED

0.05 A

6A

1 ballast

60 ballasts

Ceiling Fan

0.083 A

2A

Lighting

10 W / VA

8A

Motor

0.08 A

1/4 HP 5.8 A

Lighting

40 W / VA

8A

Motor

0.4 A

1/10 HP 3A

See Dimmer See Switch

-RD-27711

See Dimmer

Dimmer

-6NA

Switch

-10D, -10ND

800 W /  1000 VA

MLV2

-RS10 -RS-277

50 W / VA

-6D

1000 W

Incand.

-RD10

11

50 W

8.3 A

See Switch

1 Dimmer Load Type: -6D, -10D and -10ND are designed for use with permanently installed incandescent, magnetic low-voltage, or tungsten halogen only. -6NA is designed for use with permanently installed incandescent, electronic low-voltage, magnetic low-voltage, or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances. Do not mix incandescent, halogen, MLV, or ELV load types on a dimmer. 2 Low-Voltage Applications: Use -6D,-10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers.  Use -6NA with dimmable electronic (solid-state) or magnetic (core and coil) transformers.  Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: a. Do not operate low-voltage circuits without operative lamps in place. b. Replace burned-out lamps as quickly as possible. c. Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. 3 Fluorescent Dimmer Load Type: -F6AN-DV is designed for use with permanently installed 3-wire 120 V~ or 277 V~ line voltage control fluorescent ballasts or LED drivers. Use only with Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, or EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Do NOT use with any other ballasts or drivers. Do not install to control receptacles or motor-operated appliances.

Remote Dimmer

-F6AN-DV*

Remote Switch

Fan Speed Contol

Important Notes WARNING – Entrapment Hazard – To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment which is not visible from every control location or which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death. Codes: Install in accordance with all local and national electrical codes. Grounding: When no “grounding means” exist in wallbox, the 2011 National Electrical Code® (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove green wire before screwing control into wallbox.

Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, noncondensing. Indoor use only. Spacing: If mounting one control above another, leave at least 4 ½ in (114 mm) vertical space between them.

5 Maximum Load: The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS.

Wallplates: Lutron® Claro® and Satin Colors® wallplates are recommended for best color match and aesthetic appearance. Do not paint controls or wallplates.

6  Ceiling Fan Application (-2ANF): • Use to control one paddle-type ceiling fan (permanent split-capacitor). • Use the ceiling fan’s pull chain to set its speed to the highest setting. • Do not use to control fans that use shaded-pole motors (i.e. bath exhaust fans). • Do not use to control fans that have integrated fan speed controls (i.e. fans that have a remote control), unless the integrated control is removed from the ceiling fan. • Do not connect to any other motor-operated appliance or to any lighting load type. • Do not use to control a fan lighting load (i.e. light kit). 7 Switch Load Type -8ANS: -8ANS is designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, or fluorescent loads and with motor loads up to 1/4 HP (5.8 A). 8 Switch Load Type -8S-DV: -8S-DV is designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, fluorescent, or motor loads; or 277 V~ magnetic low-voltage or fluorescent loads. 9 Shunt Capacitor (included): Some -8S-DV installations may require the use of a shunt capacitor. This is especially necessary for load types sensitive to leakage current (i.e. fluorescent ballasts). If load flickers, install a shunt capacitor. For shunt capacitor installation see Wiring Diagram 4 or 8. 10 120 V~ Remote Dimmer / Switch: -RD and -RS are designed for use with 120 V~ dimmers / switches. 11 277 V~ Remote Dimmer / Switch: -RD-277 and -RS-277 are designed for use with 277 V~ dimmers / switches. Do NOT use with motor loads.

Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions. Wallboxes: Lutron recommends using 3 ½ in (89 mm) deep wallboxes for easier installation. Several controls may be installed in one multigang wallbox. See Derating Chart. Remotes: Use only remote dimmers (-RD / -RD-277) and remote switches (-RS / -RS-277)with dimmers /switches / fan speed controls. Up to 9 -RD / -RD-277 or -RS / -RS-277 may be used with controls. Mechanical 3- or 4-way switches will not work. RF Device Placement: RF dimmers /switches and fan controls must be located within 30 ft (9 m) of an RF Signal Repeater. Remote dimmers / switches are not required to be within a specific range of a repeater. For systems with an RF signal repeater, RF dimmers / switches / fan speed controls cannot be controlled by the system until they are programmed in a system according to the system Setup Guide.

* Typical Power Consumption:

Dimmer / Switch / Fan Speed Control: 0.6 W (Load is off, nightlight mode enabled.) Remote Dimmer / Switch: 0 W (Load is off.)

Technical Assistance: U.S.A. / Canada: 1.800.523.9466 | Mexico: +1.888.235.2910 Brazil: +55 (11) 3257-6745 (M-F 8:30 to 17:30 BRT) | Other Countries: +1.610.282.3800 24 hours a day, 7 days a week www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012

-2ANF -8ANS

Load Type

Wrap wire around screw terminal. Tighten securely to 5 in-lb (0.55 N•m).

End of Gang

Middle of Gang

Incand.

500 W

400 W

MLV

400 W /  500 VA

300 W /  400 VA

Incand./ ELV

500 W

400 W

b. W  ire Connectors: Prepare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connector.

MLV

400 W /  500 VA

300 W /  400 VA

NOTE: Wire connectors provided are suitable for copper wire only.

Incand.

800 W

650 W

Wire Connector:

MLV

600 W /  800 VA

500 W /  650 VA

• S  trip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm2) or 12 AWG (2.5 mm2) wire.

3-wire Fluorescent/ LED

5A

3.5 A

50 ballasts

35 ballasts

Ceiling Fan

2A

2A

Lighting

6.5 A

5A

Motor

1/4 HP 5.8 A

1/6 HP 4.4 A

Lighting

8 A (2-gang) 7 A (3-gang)

7A

-8S-DV Motor

• S  trip insulation 7/16 in (11 mm) for 18 AWG (0.75 mm2) or 16 AWG (1.0 mm2) wire. • U  se to join one or two 14 AWG (1.5 mm2) or 12 AWG (2.5 mm2) wires with one 18 AWG (0.75 mm2) or 16 AWG (1.0 mm2) wire.

* The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS.

NOTE: -8ANS, -RD-277 and -RS-277 controls have fins that need to be removed for multigang installations. -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS controls do not have fins that need to be removed for multigang installations.

Twist wire connector tight.

Single Location Installation1 with Neutral -6NA, -10ND, -2ANF and -8ANS (120 V~)

Dimmer Brass

Control at middle of gang has all fins removed

• P  ush-In Terminals: Use with 14 AWG (1.5 mm2) solid copper wire only. Do NOT use stranded or twisted wire. Insert wires fully. To release wire, insert small, flat screwdriver into slot below push-in terminal. Push screwdriver in while pulling wire out.

OR

Probable Cause and Action

Light / fan doesn’t turn ON / OFF when tapswitch on dimmer / switch / fan speed control or remote dimmer / switch is pressed

Power not present • Circuit breaker OFF or tripped. Perform short circuit check. • FASS™ is in the OFF position. Move FASS™ to the ON position. Check the dimmer / switch / fan speed control and all of the remote dimmers / switches. See Lamp Replacement. Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or-8ANS. See Load Specifications.

Load

Neutral

Wiring Diagram 3

Wiring Diagram 4

Single Location Installation1 with Neutral -F6AN-DV (120/277 V~)

Single Location Installation1 without Neutral -8S-DV with optional shunt capacitor2 (120-277 V~)

Dimmer Brass Hot/Live Silver

Black Orange White

Blue 1 Orange

Black

Green

120/277 V~ 50/60 Hz

Black Orange White

Ground

Neutral

Load is less than minimum load requirement • Make sure the connected load meets the appropriate minimum load requirement for that control. See Load Specifications. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or -8ANS. See Load Specifications.

Switch Blue 1

Brass Hot/Live Black

Lamps burned out or not installed • Replace or install lamps.

Optional

Green

120-277 V~ 50/60 Hz

Shunt Capacitor2

Load

Dioded lamps • If dioded lamps are being used, replace with non-dioded lamps.

Ground

Neutral

Fan setting • Make sure the fan is set to its highest speed using the pull-chain. Fan Speed Control Wrong Load Type • Make sure that only a single ceiling paddle fan (permanent split-capacitor motor) rated at 2 A or less is connected to the control. • Make sure that no lighting load (i.e. light kit) is connected to the control.

Wiring Diagram 5 Multi-Location Installation3 without Neutral -6D, -10D with -RD (120 V~)

Blue

Brass Black

Green

 Dimmer / Remote Dimmer3

Blue

Brass

Blue

Black

Green

NOTE: Dimmer may be installed in any location in the circuit.

Green Load

Ground

Ground

Neutral

Load flickers or tapswitch does not work even if load is greater than 40 W (-8S-DV only)

Leakage current • Install a shunt capacitor. See Wiring Diagram 4 or 8.

Light turns ON and OFF continuously or lights turn ON when tapswitch is pressed, then turn OFF

Load does not meet the minimum load requirement • Increase load to meet the appropriate minimum load requirement for that control. See Load Specifications. • Install a shunt capacitor with -8S-DV. See See Wiring Diagram 4 or 8. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or -8ANS. See Load Specifications.

Load flickers (-8S-DV only)

Load does not meet the minimum load requirement • Increase load to meet the appropriate minimum load requirement for that control. See Load Specifications. • Install a shunt capacitor. See Wiring Diagram 4 or 8.

Lights/Fans don’t turn ON/ OFF from a keypad

Improper programming • Program according to the system Setup Guide.

Wiring Diagram 6 4. Push all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws provided. Do not pinch the wires.

a. Install wallplate adapter onto front of control(s).

Multi-Location Installation3 with Neutral4 -6NA, -10ND, and -2ANF with RD-RD, and -8ANS with RD-RS (120 V~) Remote Dimmer/ Remote Switch

Brass

Brass

Blue

Hot/Live Black

Green

120 V~ 50/60 Hz

Black

Black

Green

Ground

Blue

Brass Silver

Blue

Wiring Diagram 7 Multi-Location Dimmer Installation3 with Neutral 4 -F6AN-DV with -RD or -RD-277 (120/277 V~)

Ground

Remote Dimmer Brass/ Red

Remote Dimmer

Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams.

Blue

Brass/ Red

Brass

Blue

Silver

Hot/Live Black

Black

Green

120/277 V~ 50/60 Hz

Wallplate is warm NOTE: Dimmer must be installed on the load side of the circuit.

 Dimmer 

Black

Green Ground

Black Orange White

Blue Orange Green

Black Orange White

Ground

Neutral

Wallplate Wallplate Control Adapter Adapter Mounting Mounting Screws Screws

Out of RF range • Reposition to be within 30 ft (9 m) of an RF signal repeater.

Load

Neutral

Ground

Mounting Diagram

NOTE: Dimmer must be installed on the load side of the circuit.

Green

Ground

c. Snap wallplate onto wallplate adapter, and verify that control is aligned properly.

6. Restore power. Verify correct local operation. See Dimmer/Fan Operation or Switch Operation.

Dimmer / Switch / Fan Speed Control

Remote Dimmer/ Remote Switch

b. Tighten control mounting screws until wallplate adapter is flush to wall (do not over-tighten).

Solid-state control dissipation • Solid-state dimmers / switches / fan speed controls internally dissipate about 2% of the total connected load. It is normal for dimmers / switches / fan speed controls to feel warm to the touch during operation.

NOTE: Refer to the system Setup Guide for additional troubleshooting suggestions.

Wiring Diagram 8 Multi-Location Installation 3 without Neutral -8S-DV with -RS or -RS-277 and optional shunt capacitor2 (120– 277 V~) Remote Switch /  Switch3 Brass/ Red

Remote Switch /  Switch3 Brass/ Red

Blue

Blue

Switch / Remote Switch3 Brass/ Red

NOTE: Switch may be installed in any location in the circuit.

Blue

Hot/Live Wallbox Included:

Black

120–277 V~ 50/60 Hz

Control

Black Green

Mounting Screws (2)

Wallplate adapter and wallplate purchased separately.

Lamp Replacement WARNING – Shock Hazard – For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. Working with power ON could result in serious injury or death.

Black Green

Optional

Green

Load Ground

Wire Connectors (1 or 5)

3. Wire controls according to one of the following options: a. T  erminals: Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control.

Symptom

Ground

Ground

1. Turn power OFF at fusebox or circuit breaker. 2. Check the installation for short circuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load. Restore power. If lights or fans do not work or a breaker trips, check wiring. Correct wiring and check again. Install control(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit.

Green

120 V~ 50/60 Hz

Neutral

120 V~ 50/60 Hz

Installation WARNING – Shock Hazard – To avoid the risk of electric shock locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON could result in serious injury or death.

Black Load

Ground

d. If controls are misaligned, loosen mounting screws appropriately. Each control has inside fins removed

Silver

Hot/Live Green

120 V~ 50/60 Hz

Brass

For single and multi-location installations see Wiring Diagrams.

Blue 1

Brass

Hot/Live Black

Troubleshooting Guide

Dimmer/Switch/ Fan Speed Control Blue 1

Hot/Live Black

5. Attach the Lutron® Claro® or Satin Colors® wallplate adapter and wallplate. See Mounting Diagram. Do Not remove outside fins on controls at the end of gang

Wiring Diagram 2

Single Location Installation1 without Neutral -6D, -10D (120 V~)

Remote Dimmer / Dimmer3 Remote Dimmer / Dimmer3

1/10 HP 3A

Neutral Wire: -6NA, -10ND, -F6AN-DV, -2ANF, and -8ANS require a neutral wire connection in the wallbox where the dimmer/switch/fan control is to be installed. If a neutral wire connection is not available in the wallbox, contact a licensed electrician for installation.

4 Power Boosters / Load Interfaces: -6NA, -10ND, -F6AN-DV, and -8ANS can be used to control power boosters / load interfaces. For a list of compatible power boosters / load interfaces see Lutron P/N 369225.



When combining controls in a wallbox, derating is required; however, no derating is required for fan speed controls and remote dimmers / switches.

Wiring Diagram 1

Lutron® Ballast / LED Driver

Please Read Before Installing

Designer-Style RF Maestro®

* Dimmer: RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Switch: RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz)

• S  crew Terminals: Use with 12 AWG (2.5 mm2) or 14 AWG (1.5 mm2) solid copper wire only. Do NOT use stranded or twisted wire.

Lutron® Ballast / LED Driver

In multigang installations, several controls are grouped horizontally in one multigang wallbox.

Lutron® Ballast / LED Driver

Multigang Installations

Lutron® Ballast / LED Driver

English Installation Instructions

Ground

Shunt Capacitor2

Ground

Neutral

1W  hen using controls in single location installations, tighten the blue terminal without any wires attached. DO NOT connect the blue terminal to any other wiring or to ground. 2 Shunt capacitor must be installed inside the load fixture or in a separate J-box. 3 Install only 1 dimmer / switch / fan speed control per circuit. Up to 9 remote dimmers / switches may be connected to a dimmer / switch / fan speed control. Total blue terminal wire length may be up to 250 ft (76 m). 4 Neutral wire dimmers / switches / fan speed controls must be connected on the Load side of a multi-location installation.

Dimmer/Fan Operation

For your safety during routine lamp replacement, remove power from the fixture(s) by moving the FASS™ switch into the OFF position on the dimmer / switch and all remote dimmers / switches. Dimmer Shown

Switch Operation

Status LEDs Indicate light level; glows softly as night light when load is off Tapswitch Tap on/off

Status LED Indicates light status; glows softly as night light when load is off

Dimming Rocker Press to Brighten or Increase Speed Press to Dim  or Decrease Speed

Tapswitch Tap on/off

FASS™ Front Accessible Service Switch

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, and ) are registered trademarks and RadioRA 2, Compact SE, and FASS are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc.

FASS™ Front Accessible Service Switch

-RD-277 or -RS-277 only OR OFF

ON

Return to Factory Settings NOTE: Returning a dimmer / switch / fan speed contol to its factory settings will remove it from the system and erase all programming from it. Step 1 : T  riple tap the tapswitch on a control. DO NOT release after the third tap. Step 2 : K  eep the tapswitch pressed on the third tap (for approximately 3 seconds) until the LEDs on the dimmer start to scroll up and down quickly, or the LED on the switch flashes quickly Step 3 : Release the tapswitch and immediately triple tap the tapswitch again. The LEDs on the dimmer will scroll up and down slowly. The LED on the switch will flash slowly. The control has now been returned to factory settings and needs to be reprogrammed into a system. Warranty: See the Warranty enclosed with the product, or visit www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf

Instalaciones con múltiples dispositivos

*C  ontrol de velocidad de ventilador: RRD-2ANF (120 V~ 50 / 60 Hz) * Atenuadores accesorios: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz)

* Interruptores accesorios: RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz)

Para la Guía de configuración del sistema y otras herramientas visite: www.lutron.com/radiora2

Especificaciones de la carga Control -6D1

Tipo de carga

Carga mín. Carga máx.

Incand.

50 W

600 W

BVM

50 W / VA

450 W /  600 VA

Incand./ BVE2

5W

600 W

BVM2

5 W / VA

450 W /  600 VA

Incand.

50 W

1 000 W

BVM2

50 W / VA

800 W /  1 000 VA

2

-6NA1

-10D1

-10ND1

Incand.

10 W

1 000 W

BVM2

10 W / VA

800 W /  1 000 VA

0,05 A de 3 -F6AN-DV3, 4, 5 Fluorescente conductores / LED 1 balasto

6A

-2ANF6

Ventilador de techo 0,083 A

2A

Iluminación

10 W / VA

8A

Motor

0,08 A

1/4 HP 5,8 A

Iluminación

40 W / VA

8A

Motor

0,4 A

1/10 HP 3A

-8ANS7

-8S-DV8, 9 -RD10

60 balastos

Ver el Atenuador

-RS10

Vea Interruptor 11

Ver el Atenuador

11

Vea Interruptor

-RD-277 -RS-277

8,3 A

1 Tipo de carga del atenuador: Los modelos -6D, -10D y -10ND están diseñados para usarse solamente con cargas incandescentes, magnéticas de bajo voltaje, o halógenas de tungsteno instaladas en forma permanente. El modelo -6NA está diseñado para usarse solamente con cargas incandescentes, electrónicos de bajo voltaje, magnéticas de bajo voltaje, o halógenas de tungsteno instaladas en forma permanente. No instale atenuadores para controlar tomas de corriente ni dispositivos motorizados. No combinar tipos de carga incandescente, halógena, BVM o BVE en un atenuador. 2 Uso con bajo voltaje: Use los modelos -6D, -10D y -10ND solamente con transformadores magnéticos (de bobina y núcleo) de bajo voltaje. No los use con transformadores electrónicos (de estado sólido). Use el modelo -6NA con transformadores atenuables electrónicos (de estado sólido) o magnéticos (de bobina y núcleo) de bajo voltaje. El funcionamiento de un circuito de bajo voltaje sin lámparas o con lámparas que no funcionan puede resultar en el sobrecalentamiento del transformador y fallas prematuras. Lutron recomienda firmemente lo siguiente: a. No opere circuitos de bajo voltaje sin las lámparas en condiciones operativas en su lugar. b. Reemplace las lámparas quemadas lo más rápido posible. c. Use transformadores que incorporan protección térmica o con fusibles en los bobinados primarios para prevenir fallas del transformador provocadas por sobrecorrientes. 3 Tipo de carga del atenuador para luces fluorescentes: El -F6AN-DV está diseñado para ser usado con drivers de LED o balastos de luces fluorescentes de 3 conductores, de 120 V~ o 277 V~, instalados en forma permanente y controlados a través del voltaje de línea. Use sólo con Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, o EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). NO usar con otros balastos o drivers. No lo instale para controlar tomas de corriente ni electrodomésticos operados por motor. 4 Amplificadores de potencia / Interfaces de carga: -6NA, -10ND, -F6AN-DV, y -8ANS se pueden utilizar para controlar amplificadores de poder/interfaces de carga. Para obtener una lista de amplificadores de poder/interfaces de carga compatibles, consulte Lutron P/N 369225. 5 Carga Máxima: La carga máxima para el -F6AN-DV es la carga reducida o el número de balastos, lo que fuera MENOR. 6 Aplicación de ventilador de techo (-2ANF): • Use para controlar un ventilador de techo de paletas (decondensador permanente). • Use la cadena del ventilador de techo para configurar su velocidad en el valor más alto posible. • No use para controlar ventiladores que usan motores de anillos de desfase (como extractores). • No use para controlar ventiladores que tienen un control de velocidad integrado (por ejemplo ventiladores que tienen un control remoto), a menos que el control integrado se remueva del ventilador de techo. • No conecte ningún otro dispositivo operado a motor o ningún tipo de carga de iluminación. • No lo use para controlar una carga de iluminación de ventilador (por ejemplo juego de luz). 7 Tipo de carga del interruptor -8ANS: el modelo -8ANS está diseñado para usar con cargas incandescentes, de bajo voltaje magnético, de bajo voltaje electrónico, o fluorecentes instaladas en forma permanente y con cargas de motores de hasta 1/4 HP (5,8 A). 8  Tipo de carga del interruptor -8S-DV: El -8S-DV está diseñado para uso con cargas permanentemente instaladas de 120 V~, incandescentes, de bajo voltaje magnético o electrónico, fluorescentes, o motores; o con cargas de 277 V~, fluorescentes o de bajo voltaje magnético). 9  Condensador paralelo (incluido): ciertas instalaciones -8S-DV pueden requerir el uso de un condensador paralelo. Esto es especialmente necesario con tipos de carga sensibles a la corriente de fuga (por ejemplo balastos fluorescentes). Si la carga parpadea, instale un condensador en paralelo. Para la instalación del condensador paralelo vea el Diagrama de cableado 4 o 8. 10  Atenuador / interruptor accesorio de 120 V~: Los -RD y -RS están diseñados para usar con atenuadores / interruptores de 120 V~. 11  Atenuador / interruptor accesorio de 277 V~: Los -RD-277 y -RS-277 están diseñados para usar con atenuadores / interruptores de 277 V~. NO utilizar con una carga motorizada.

*Condiciones de la prueba de consumo típico de potencia: Dimmer / Switch / Control de velocidad de ventilador: 0,6 W (la carga está apagada, el modo de luz nocturna está habilitado.) Atenuador / Interruptor accesorio: 0 W (La carga está apagada.)

Esto no es necesario para los controles de velocidad del ventilador y atenuadores /  interruptores accesorios.

Envuelva el cable alrededor del tornillo del terminal. Apriete con firmeza hasta 0,55 N•m (5 pulg-lbs).

Cuadro de reducción de la potencia nominal

b. C  onectores de cable: Prepare los cables. Al hacer conexiones de cable, siga las longitudes para extremos pelados y las combinaciones recomendadas para los conectores proporcionados.

Control

Atenuador

-6D

Interruptor

-6NA

-10D, -10ND

Atenuador accesorio

Interruptor accesorio

Control de velocidad de ventilador

Notas importantes ADVERTENCIA – Riesgo de quedar atrapado – Para evitar el riesgo de quedar atrapado, de lesiones graves o la muerte, estos controles no deben usarse para controlar equipos que no sean visibles desde todos los puntos de control o que puedan causar situaciones peligrosas, como quedar atrapado, si se operan accidentalmente. Como ejemplos de equipos que no deben operarse con estos controles podemos citar (sin limitación) portones motorizados, puertas de garaje, puertas industriales, hornos de microondas, almohadillas de calentamiento, etc. Es responsabilidad del instalador asegurar que el equipo que se controla sea visible desde todos los puntos de control y que sólo se conecten equipos adecuados a estos controles. La falta de cumplimiento podría resultar en lesiones graves o la muerte. Códigos: Realice la instalación de acuerdo con todos los códigos eléctricos locales y nacionales. Conexión a tierra: Cuando dentro de la caja de empotrar no hay “medios de conexión a tierra”, el National Electrical Code® 2011 permite la instalación de un control como reemplazo, siempre y cuando 1) se utilice una placa frontal no metálica e incombustible con tornillos de fijación no metálicos o 2) el circuito se encuentre protegido por un interruptor de circuitos de fallas de conexión a tierra (GFCI). Al instalar un control de acuerdo con estos métodos, tape o retire al cable verde antes de atornillar el control en la caja de empotrar. Cables neutros: Los modelos -6NA, -10ND, -F6AN-DV, -2ANF, y -8ANS requieren una conexión de neutro en la caja de empotrar en que se instalará el atenuador/interruptor/control de ventilador. Si no hay disponible una conexión de neutro en la caja de empotrar, contacte a un electricista autorizado para instalarlo. Condiciones ambientales: Temperatura ambiente de operación: de 0 ºC a 40 °C (32 °F a 104 °F), humedad de 0% a 90%, sin condensación. Sólo para uso en interiores. Espaciado: Si se monta un control sobre otro, deje por lo menos 114 mm (4 ½ pulg) de espacio vertical entre ellos. Placas: Las placas Claro® y Satin Colors® de Lutron® se recomiendan para una mejor combinación de colores y aspecto estético. No pinte los controles ni las placas. Limpieza: Para limpiar, pase un trapo húmedo. NO use ninguna solución química. Cajas de empotrar: Para facilitar la instalación, Lutron recomienda el uso de cajas de empotrar de 89 mm (3 ½ pulg) de profundidad. Varios controles pueden instalarse en una caja para dispositivos múltiples – vea el Cuadro de Reducción de la Potencia Nominal. Atenuadores / Interruptores remotos: utilice solamente los atenuadores remotos (-RD / -RD-277) e interruptores remotos (-RS / -RS-277) con atenuadores / interruptores  / control de velocidad de ventilador. Con estos atenuadores o interruptores pueden usarse hasta 9 -RD / -RD-277 o -RS / -RS-277. Los interruptores mecánicos de 3 o 4 vías no funcionarán. Ubicación del dispositivo de RF: los atenuadores / interruptores y controles de velocidad de ventilador de RF deben ubicarse a menos de 9 m (30 pies) de un repetidor de señales de RF. Los atenuadores / interruptores accesorios no están sujetos a esta limitación de estar ubicados a cierta distancia de un repetidor. En sistemas con un repetidor de señal de RF, los atenuadores / interruptores / control de velocidad de ventilador de RF no pueden ser controlados por el sistema hasta que hayan sido programados de acuerdo con la Guía de configuración del sistema.

Asistencia técnica: E.U.A. / Canadá: 1.800.523.9466 | México: +1.888.235.2910 Brasil: +55 (11) 3257-6745 (Lunes-Viernes 8:30 to 17:30 BRT) | Otros países: +1.610.282.3800 24 horas al día, los 7 días de la semana www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012

Cuando se combinan controles en una caja de empotrar se requiere reducir la potencia nominal.

• T  erminales de tornillo: Use solamente con cables de cobre sólidos de 2,5 mm2 (12 AWG) ó 1,5 mm2 (14 AWG). NO utilice cable retorcido ni trenzado.

Tipo de carga

Extremos de la agrupación

Medio de la agrupación

Incand.

500 W

400 W

BVM

400 W /  500 VA

300 W /  400 VA

Incand./ BVE

500 W

400 W

BVM

400 W /  500 VA

300 W /  400 VA

Incand.

800 W

650 W

600 W /  800 VA

BVM

500 W /  650 VA

-F6AN-DV*

Fluorescente de 3 conductores / LED

5A

3,5 A

50 balastos

35 balastos

-2ANF

Ventilador de techo

2A

2A

Iluminación

6,5 A

5A

Motor

1/4 HP 5,8 A

1/6 HP 4,4 A

Iluminación

8 A (2-dispositivos) 7 A (3-dispositivos)

7A

Motor

1/10 HP 3A

-8ANS

-8S-DV

* La carga máxima para el -F6AN-DV es la carga reducida o el número de balastos, lo que fuera MENOR.

NOTA: Los controles -8ANS, -RD-277 and -RS-277 tienen aletas que se deben quitar para instalaciones de dispositivos múltiples. Los controles -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS no tienen aletas que deban quitarse para instalaciones de dispositivos múltiples. No quite las aletas exteriores de los controles en ambos extremos de la agrupación

NOTA: Los conectores provistos son para cable de cobre solamente. Conector de cable: • Pele 10 mm (3/8 pulg) de aislamiento para cables de 1,5 mm2 (14 AWG) o 2,5 mm2 (12 AWG). • P  ele 11 mm (7/16 pulg) de aislamiento para cables de 0,75 mm2 (18 AWG) o 1,0 mm2 (16 AWG). • Use para unir uno o dos cables de 1,5 mm2 (14 AWG) o 2,5 mm2 (12 AWG) con un cable de 0,75 mm2 (18 AWG) o 1,0 mm2 (16 AWG).

Gire el conector de cable para afirmarlo

Al control en medio de la agrupación se le han quitado todas las aletas

Instalación ADVERTENCIA – Peligro de descarga eléctrica – Para evitarla, ubique y retire el fusible o asegure el disyuntor en la posición de APAGADO antes de proceder. Cablear con la alimentación ENCENDIDA podría causar lesiones graves o la muerte. 1. DESCONECTE la alimentación en la caja de fusibles o en el disyuntor. 2. Verifique que no haya cortocircuitos en la instalación antes de instalar el(los) control(es). Con la alimentación DESCONECTADA, instale interruptores mecánicos estándar entre el vivo y la carga. Restablezca la alimentación. Si las luces o ventiladores no funcionan o un disyuntor se dispara, corrija el cableado y verifique nuevamente. Instale el(los) control(es) solamente cuando ya no haya cortocircuito. La garantía es nula si el control se ENCIENDE con un cortocircuito. 3. Cablee los controles de acuerdo con una de las opciones siguientes: a. T  erminales: Recorte o pele los cables de la caja de empotrar hasta la medida indicada en el reverso del control. • Terminales de insertar: Use únicamente con cables de cobre sólido de 1,5 mm2 (14 AWG). NO utilice cable trenzado ni retorcido. Inserte completamente los cables. Para soltar el cable, inserte un destornillador chato pequeño dentro de la ranura debajo del terminal a presión. Empuje el destornillador mientras tira el cable hacia afuera. O

Diagrama de cableado 2

Instalación1 en un solo lugar sin neutro -6D, -10D (120 V~)

Instalación1 en un solo lugar con neutro -6NA, -10ND, -2ANF y -8ANS (120 V~) Atenuador / interruptor / Control de velocidad de ventilador

Interruptor Latón

Azul 1

Vivo

Latón Plata

Vivo

Negro

Azul 1

Negro

Verde

120 V~ 50/60 Hz

Guía para la solución de problemas

Verde

120 V~ 50/60 Hz

Carga Tierra

Carga

Tierra

Neutro

Síntoma

Probable Causa y Acción

Luz / ventilador no se ENCIENDEN / APAGAN cuando se presiona el interruptor de presión del atenuador / interruptor / control de velocidad de ventilador o del atenuador / interruptor accesorio.

No hay alimentación • Disyuntor APAGADO o se disparó. Verifique si hay cortocircuito. • Interruptor FASS™ en la posición de APAGADO. Cambie el FASS™ a la posición de ENCENDIDO. Verifique el atenuador / interruptor / control de velocidad de ventilador y todos los atenuadores / interruptores accesorios. Consulte Reemplazo de lámparas.

Neutro

Diagrama de cableado 3

Diagrama de cableado 4

Instalación1 en un solo lugar sin neutro -8S-DV con condensador paralelo opcional2 (120-277 V~)

Instalación1 en un solo lugar con neutro -F6AN-DV (120/277 V~) Atenuador Latón Vivo Plateado Negro 120/277 V~ 50/60 Hz

Interruptor Negro Naranja Blanco

Azul1 Naranja Verde

Negro Naranja Blanco

Tierra

Neutro

Latón

Negro

Opcional

Verde

120-277 V~ 50/60 Hz

Condensador paralelo2

Carga Tierra

Neutro

Las lámparas están quemadas o no están instaladas. • Reemplace o instale lámparas.

Diagrama de cableado 5

Lámparas de diodo • Si se están usando lámparas de diodo, reemplácelas por lámparas sin diodos.

Instalación de un interruptor en múltiples ubicaciones3 -6D, -10D with -RD (120 V~) Atenuador accesorio/ Atenuador3

Atenuador accesorio/ Atenuador3

Latón

Latón

Azul

Azul

Atenuador3/ Atenuador accesorio

Latón

Negro

Negro

Configuración del ventilador • Asegúrese que el ventilador está en su velocidad máxima utilizando la cadena.

NOTA: El attenuador puede ser instalado en cualquier lugar del circuito.

Azul

Verde

120 V~ 50/60 Hz

Tipo de carga incorrecto del control de velocidad del ventilador • Asegúrese que solamente un único ventilador de paletas (motor de condensador permanente) de 2 A o menos está conectado al control. • Asegúrese que ninguna carga de iluminación (por ejemplo un juego de luz) está conectado al control.

Verde Carga

Tierra

Para instalaciones en una sola y múltiples ubicaciones vea el diagramas de cableado.

Verde

Negro

Tierra

Tierra

Neutro

Diagrama de cableado 6 4. Inserte todos los cables en la caja de empotrar y coloque el control en la caja usando los tornillos de montaje provistos. No pellizque los cables. 5. Coloque el adaptador y la placa Lutron® Claro® o Satin Colors®. Consulte Diagrama de montaje.

Instalación3 con control desde varios lugares, con neutro4 -6NA, -10ND, -2ANF con RD-RD, y -8ANS con RD-RS (120 V~) Atenuador accesorio/ interruptor accesorio

Latón Negro 120 V~ 50/60 Hz

b. Ajuste los tornillos de montaje del control hasta que el adaptador de placa esté a ras con la pared (no los sobreajuste).

Neutro

6. Restablezca la alimentación. Verifique que el funcionamiento local sea correcto. Consulte Operación del atenuador / ventilador u Operación del interruptor.

Latón

Atenuador / interruptor / Control de velocidad de ventilador

Azul

Latón Plata

Vivo

a. Instale el adaptador de la placa sobre el frente del (los) control(es).

d. Si los controles quedaron mal alineados, afloje los tornillos de montaje según corresponda.

Azul

Atenuador accesorio/ interruptor accesorio

Verde

Negro

Verde

Tierra

Diagrama de cableado 7 Instalación3 de un atenuador en múltiples ubicaciones con neutro4 -F6AN-DV con -RD o -RD-277 (120/277 V~) Atenuador accesorio

Latón/ Rojo

Vivo

Negro 120/277 V~ 50/60 Hz

Azul

Atenuador accesorio

Latón/ Rojo

Azul

Negro

Atenuador

Latón Plateado Negro

Verde

Verde

Tierra

Azul Naranja

NOTA: El atenuador debe ser instalado del lado de la carga del circuito Negro Naranja Blanco

Verde

Tierra

Tierra

Negro Naranja Blanco

Adaptador Placa de placa Tornillos de Tornillos de montaje del montaje del control adaptador

Latón/ Rojo

Latón/ Rojo

Azul

Azul

Azul

La carga no cumple con los requisitos de carga mínima • Aumente la carga para cumplir con los requisitos de carga mínima de ese control. Vea Especificaciones de la carga. • Instale un condensador en paralelo con el -8S-DV. Vea el Diagrama de cableado 4 o 8. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga.

La carga parpadea (-8S-DV solamente)

La carga no cumple los requisitos mínimos de carga • Aumente la carga para cumplir con los requisitos de carga mínima de ese control. Vea Especificaciones de la carga. • Instale un condensador paralelo. Vea el Diagrama de cableado 4 o 8.

Las luces / ventiladores no se ENCIENDEN/APAGAN desde un teclado

Programación incorrecta • Programe todos los dispositivos según la Guía de configuración del sistema.

La placa de pared está caliente

Interruptor3/ Interruptor accesorio Latón/ Rojo

La luz se ENCIENDE y se APAGA continuamente o las luces se ENCIENDEN cuando se presiona el interruptor, luego se APAGAN

Cableado • Cables en cortocircuito. Asegúrese de que el terminal azul no esté conectado a tierra o en cortocircuito con otros cables. • Error en el cableado. Verifique el cableado para asegurarse de que cumpla con las instrucciones de instalación y con los diagramas de cableado.

Instalación de un interruptor en múltiples ubicaciones3 -8S-DV con -RS o -RS-277 y condensador paralelo opcional2 (120– 277 V~) Interruptor accesorio/ Interruptor3

Corriente de fuga • Instale un condensador paralelo. Vea el Diagrama de cableado 4 o 8.

Fuera del alcance de RF • Reubique para estar a no más de 9 m (30 pies) de un repetidor de señales de RF.

Diagrama de cableado 8 Interruptor accesorio/ Interruptor3

La carga parpadea o interruptor a presión no funciona incluso si la carga es superior a 40 W (-8S-DV solamente)

Carga

Tierra

Neutro

Diagrama de montaje

NOTA: El atenuador debe ser instalado del lado de la carga del circuito

Azul

Negro

Verde

Tierra

Cableado • Cables en cortocircuito. Asegúrese de que el terminal azul no esté conectado a tierra o en cortocircuito con otros cables. • Error en el cableado. Verifique el cableado para asegurarse de que cumpla con las instrucciones de instalación y con los diagramas de cableado. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga. La carga es menor que la carga mínima requerida • Asegúrese de que la carga conectada cumpla con los requerimientos de carga mínima para ese control. Vea la Especificaciones de carga. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga.

Azul1

Vivo

Vivo

c. Presione la placa sobre el adaptador y verifique que el control esté correctamente alineado. A cada control se le han quitado las aletas interiores

Diagrama de cableado 1

Driver Lutron® Driver Lutron® de balasto/ de balasto/ LED LED

Por favor, lea antes de instalar

Maestro® RF estilo designer

* Atenuador: RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Interruptor: RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz)

En instalaciones con dispositivos múltiples, se agrupan varios controles horizontalmente en una caja de empotrar para dispositivos múltiples.

Driver Lutron® Driver Lutron® de balasto/ de balasto/ LED LED

Español Instrucciones de instalación

Disipación de calor del control de estado sólido • Los atenuadores / interruptores / controles de velocidad de ventilador de estado sólido disipan internamente cerca del 2% de la carga total conectada. Es normal que atenuadores / interruptores / controles de velocidad de ventilador se sientan tibios al tacto durante el funcionamiento.

NOTA: Consulte la guía de configuración del sistema para sugerencias adicionales de solución de problemas.

NOTA: El interruptor puede ser instalado en cualquier lugar del circuito.

Vivo Negro Caja de empotrar Se incluye:

120–277 V~ 50/60 Hz

Control

Conectores de cable (1 o 5)

El adaptador y la placa se venden por separado.

Tornillos de montaje (2)

Reemplazo de lámparas ADVERTENCIA – Peligro de choque eléctrico – Para cualquier otro procedimiento que no sea el reemplazo habitual de las lámparas se debe desconectar la alimentación desde el panel eléctrico principal. Trabajar con la alimentación CONECTADA puede resultar en lesiones personales graves o la muerte. Para su seguridad durante el reemplazo rutinario de lámparas, desconecte la alimentación del(los) artefacto(s) tirando hacia afuera el interruptor FASS™, a la posición APAGADO, en el atenuador / interruptor y también en todos los atenuadores / interruptores accesorios.

Verde

Negro

Verde

Negro

Opcional

Verde Carga

Tierra

Tierra

Condensador paralelo2

Tierra

Neutro

1C  uando se usan controles en instalaciones con control desde un solo lugar, ajuste el terminal azul sin conectar ningún cable al mismo. NO conecte el terminal azul a ningún otro cable ni a tierra. 2 El condensador paralelo debe ser instalado dentro del artefacto de carga o en una caja J separada. 3 Instalar solamente una (1) atenuador / interruptor / control de velocidad de ventilador por circuito. A un mismo atenuador / interruptor pueden conectarse hasta 9 atenuadores / interruptores / controles de velocidad de ventilador. El largo total del cable del terminal azul puede ser hasta 76 m (250 pies). 4 Los atenuadores / interruptores / controles de velocidad de ventilador con cable neutro deben conectarse del lado de la carga de una instalación desde múltiples lugares.

Operación del atenuador / ventilador

Operación del interruptor LED de estado (interruptor solamente) Indica el estado de luz; brilla suavemente como luz nocturna cuando la carga está apagada

LEDs de estado (atenuador sólo) Indican el nivel de luz; brillan suavemente como luz nocturna cuando la carga está apagada Interruptor de presión Presione para encender o apagar Balancín de atenuación Presione para aumentar la intensidad de la luz o aumentar la velocidad Presione para atenuar o bajar la velocidad

Atenuador muestra

FASS™ Frente Accesible Servicio Interruptor

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA y ) son marcas registradas, y RadioRA 2, Compact SE y FASS son marcas de Lutron Electronics Co., Inc. NEC es una marca registrada de la National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc.

Interruptor de presión Presione para encender o apagar

FASS™ Frente Accesible Servicio Interruptor

-RD-277 o -RS-277 sólo OR OFF

ON

Retorno a la configuración de fábrica NOTA: El retorno de un atenuador / interruptor / controle de velocidad de ventilador a su configuración de fábrica lo removerá del sistema y borrará toda su programación. Paso 1: P  ulse tres veces y mantenga el interruptor de presión de un control. NO suelte el botón después del tercer pulso. Paso 2 : M  antenga presionado el interruptor después del tercer pulso (durante 3 segundos aproximadamente) hasta que los LEDs del atenuador se enciendan y apaguen rápidamente en secuencia, o el LED del interruptor parpadee rápidamente. Paso 3 : S  uelte el interruptor e inmediatamente púlselo otras tres veces. Los LEDs del atenuador se encenderán y apagarán lentamente en secuencia. El LED del interruptor parpadeará lentamente. El control volvió ahora a su configuación de fábrica y deberá ser reprogramado dentro de un sistema. Garantía: Consulte la sección garantía que se incluye junto con el producto, o visite: www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf

Pour le Guide de configuration du système et outils requis, consulter le site www.lutron.com/radiora2

Spécifications de charge  Commande

Type de charge

Charge min.

Charge max.

Inc.

50 W

600 W

BTM2

50 W / VA

450 W /  600 VA

Inc./ BTE2

5W

600 W

BTM2

5 W / VA

450 W /  600 VA

Inc.

50 W

1 000 W

BTM2

50 W / VA

800 W /  1 000 VA

Inc.

10 W

1 000 W

BTM2

10 W / VA

800 W /  1 000 VA

-F6AN-DV3, 4, 5

Fluorescent/ DEL à trois (3) fils

0,05 A

6A

1 ballast

60 ballasts

-2ANF6

Ventilateur de 0,083 A plafond

2A

Éclairage

10 W / VA

8A

Moteur

0,08 A

1/4 HP 5,8 A

Éclairage

40 W / VA

8A

Moteur

0,4 A

1/10 HP 3A

-6D1

-6NA1

-10D1

-10ND1

-8ANS7

-8S-DV8, 9 -RD10

Voir gradateur

-RS10

Voir interrupteur

-RD-27711 11

-RS-277

Voir gradateur

8,3 A

Voir interrupteur

1 T  ype de charge pour gradateur : -6D, -10D et -10ND sont conçus seulement pour des charges installées en permanence, incandescentes, magnétiques à basse tension ou tungstène halogène.  -6NA est conçue seulement pour des charges installées en permanence, incandescentes, électroniques à basse tension, magnétiques à basse tension ou tungstène halogène.  Ne pas installer de gradateurs pour la commande de prises standards ou d’appareils motorisés. Ne mélangez pas les types de charge incandescente, halogène, BTM ou BTE sur un gradateur. 2 Applications à basse tension : Utilisez les gradateurs -6D, -10D et -10ND uniquement sur des charges à transformateur basse tension ferro-magnétique. Ne pas utiliser sur un transformateur électronique (à semi-conducteur). Utiliser le gradateur -6NA sur des charges à contrôlables transformateur basse tension électronique (à semi- conducteur) ou ferro-magnétique.  Le fonctionnement d’un circuit d’éclairage à basse tension ayant des ampoules hors d’usage ou non installées peut cause une surchauffe du transformateur et une défaillance prématurée. Lutron fait les recommandations suivantes : a. Ne pas utiliser les circuits à basse tension qui ne sont pas dotés de lampes en état de fonctionnement. b. Remplacer dès que possible les ampoules hors d’usage. c. Utiliser les transformateurs avec protection thermique ou enroulements primaires à fusible afin d’empêcher une défaillance causée par surintensité. 3 Type de charge pour gradateur fluorescent : Le gradateur -F6AN-DV est conçu pour utilisation avec ballasts de fluorescents ou pilotes de lampes à DEL raccordés en permanence sur un circuit 120 V~ ou 277 V~ à 3 fils. Utiliser seulement les appareils Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, or EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Ne PAS utiliser des ballasts ou pilotes différents avec ces produits. Ne pas installer pour le contrôle de prises de courant ou d’appareils motorisés. 4 Amplificateur de puissance / charge d’interfaces : -6NA, -10ND, -F6AN-DV, et -8ANS ne peut être utilisé pour contrôler amplificateur de puissance / charge d’interfaces. Pour connaître les types de amplificateur de puissance / charge d’interfaces compatibles voir Lutron P/N 369225. 5 Charge maximale : La charge maximale pour le gradateur -F6AN-DV est soit la puissance de charge déclassée soit le nombre de ballasts, selon le plus PETIT de ces deux nombres. 6  Application de ventilateur de plafond (-2ANF) : • S’utilise pour commander un seul ventilateur de plafond (moteur biphasé à condensateur permanent). • À l’aide de la chaîne à tirette, réglez la vitesse du ventilateur à son maximum*. • Ne pas utiliser pour commander les ventilateurs utilisant un moteur à pôle écran (p. ex. les ventilateurs de décharge d’air de salle de bain). • Ne pas utiliser pour commander un ventilateur qui a une commande de vitesse intégrée (ou qui est commandé à distance) à moins que la commande de vitesse soit retirée du ventilateur plafonnier*. • Ne pas raccorder à tout autre type d’appareil motorisé ou autre type de charge d’éclairage. • Ne pas utiliser pour commander une charge d’éclairage de plafonnier (luminaire). 7 Type de charge pour interrupteur -8ANS : La commande -8ANS est conçue pour une utilisation sur des charges installées en permanence, incandescentes, magnétiques à basse tension, electroniques à basse tension ou fluorescentes et charges motorisées jusqu’à 1/4 HP (5,8 A) fixes. 8 Type de charge pour interrupteur -8S-DV : Le interrupteur -8S-DV est conçu pour utilisation avec des charges motorisées, fluorescentes, incandescentes, à transformateur B.T. magnétique ou électronique raccordées en permanence sur une alimentation à 120 V~ ou avec charges fluorescentes ou à transformateur B.T. magnétique raccordées en permanence sur un circuit alimenté à 277 V~. 9  Condensateur shunt (inclus) : Certaines applications du interrupteur -8S-DV peuvent nécessiter l’installation d’un condensateur shunt. Ceci est principalement requis pour les types de charges sensibles aux courants de fuite (par ex. ballasts fluorescentes). Si la charge scintille, installer un condensateur shunt. Pour l’installation d’un condensateur shunt, voir le Schéma de câblage 4 ou 8. 10  Gradateur/interrupteur à distance à 120 V~ : Les gradateurs / interrupteurs à distance -RD et -RS sont conçus pour utilisation avec des gradateurs/interrupteurs à 120 V~. 11  Gradateur/interrupteur à distance à 277 V~ : Les gradateurs / interrupteurs à distance –RD-277 et –RS-277 sont conçus pour utilisation avec des gradateurs/interrupteurs à 277 V~. Ne PAS utiliser avec une charge motorisée.

*Conditions typiques d’essai de consommation d’énergie : Gradateur / Comutateur / Commande de vitesse de ventilateur : 0,6 W (La charge est coupée et le mode éclairage nocturne est activé.) Gradateur / Interrupteur à distance : 0 W (La charge est coupée.)

Commande

-6D

Gradateur

Interrupteur

Charge min.

Charge max.

Incand.

500 W

400 W

BTM

400 W /  500 VA

300 W /  400 VA

Incand./ BTE

500 W

400 W

-6NA

400 W /  500 VA

BTM -10D, -10ND

Gradateur à distance

Interrupteur Commande de vitesse de ventilateur à distance

Notes importantes AVERTISSEMENT – Danger d’enfermement – Pour éviter les dangers d'enfermement, de graves blessures ou le décès de personne, ces commandes ne doivent pas être utilisées pour contrôler des équipements qui ne sont pas visibles à partir de tous les emplacements de commande ou pouvant créer des situations dangereuses ou des pièges si elles sont actionnées accidentellement. Les équipements qui ne doivent pas être contrôlés par ces commandes comprennent (mais sans s’y limiter) : les barrières motorisées, les portes de garage, les portes industrielles, les fours à micro-onde, les coussins chauffants etc. Il est de la responsabilité de l’installateur de s’assurer que l’équipement commandé est visible à partir de tous les emplacements de commande et que seuls des équipements appropriés sont connectés à ces contrôles. Le non respect de cette règle peut causer des blessures graves ou fatales. Codes : Installer conformément à tous les codes électriques locaux et nationaux. Mise à la terre : Dans les cas où le boîtier mural ne possède aucun “ dispositif de raccordement de fils de terre ”, le code “ National Electrical Code® ” (NEC®) 2011 américain permet l’installation de contrôles de remplacement si : 1) une plaque frontale non métallique et ininflammable est utilisée et fixée par des vis non métalliques ou 2) le circuit est protégé par un disjoncteur de fuite de terre (GFCI). Lors de l’installation d’un contrôleur selon l’une des ces méthodes, placez un capuchon sur le fil vert (ou retirezle) avant de monter le contrôleur dans le boîtier mural. Connexion au fil de neutre : Les gradateurs -6NA, -10ND, -F6AN-DV, -2ANF, et -8ANS requièrent une connexion au fil neutre du boîte murale où les gradateur / interrupteur / commande de ventilateur doivent être installés. Si un fil neutre n’est pas présent dans le boîte murale, contacter un électricien certifié pour modifier l’installation. Environnement : Température ambiante de fonctionnement : 0 ºC à 40 °C (32 °F à 104 °F) 0 à 90% d’humidité sans condensation. Usage à l’intérieur seulement. Espacement : Pour installer une commande au-dessus d’une autre, laisser un espace vertical d’au moins 114 mm (4 ½ po) entre elles. Plaques murales : Les plaques murales Claro® et Satin Colors® de Lutron® sont recommandées pour obtenir le meilleur assortiment de couleurs et une apparence esthétique. Ne pas peindre les commandes ni les plaques murales. Nettoyage : Pour nettoyer, essuyer à l’aide d’un linge propre et humide. NE PAS utiliser de nettoyants chimiques. Plaques murales : Lutron recommande les boîtes murales de 89 mm (3 ½ po) de profondeur pour faciliter l’installation. Plusieurs commandes peuvent être regroupées dans une boîte à assemblage multiple. Voir Tableau de déclassement. Gradateurs/interrupteurs à distance : Utiliser uniquement les gradateurs à distance (-RD/ -RD-277) et interrupteurs à distance (-RS/-RS-277) avec les interrupteurs/gradateurs. Un total de 9 -RD / -RD-277 ou -RS / -RS-277 peuvent être utilisés avec les gradateurs ou interrupteurs. Les interrupteurs mécaniques à trois ou quatre voies ne sont pas compatibles avec le système. Emplacement des dispositifs RF : Les gradateurs / interrupteurs et commandes de vitesse de ventilateurs RF doivent être placés à moins de 9 m (30 pi) d’un répétiteur de signal RF. Les gradateurs/ interrupteurs à distance ne doivent pas être obligatoirement à une distance spécifique d’un répétiteur. Pour les systèmes avec un répétiteur de signal RF, les gradateurs / interrupteurs / commandes de vitesse de ventilateurs RF ne peuvent pas être commandé par le système avant d’être programmés dans un système conformément au Guide de configuration de systèmes.

Assistance technique : É.U. / Canada : 1.800.523.9466 | Mexique : 001-888-235-2910 Brésil: +55 (11) 3257-6745 (Lundi-Vendredi 8:30 to 17:30 BRT) | Autres pays : +1.610.282.3800 24 heures par jour, 7 jours par semaine www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012

Type de charge

300 W /  400 VA

Incand.

800 W

650 W

BTM

600 W /  800 VA

500 W /  650 VA

5A

3,5 A

50 ballasts

35 ballasts

-F6AN-DV*

Fluorescent/ DEL à 3 fils

-2ANF

Ventilateur de plafond

2A

2A

Éclairage

6,5 A

5A

Moteur

1/4 HP 5,8 A

1/6 HP 4,4 A

Éclairage

8A (duplex) 7A 7 A (triple)

Moteur

1/10 HP 3A

-8ANS

-8S-DV

* La charge maximale pour le gradateur -F6AN-DV est soit la puissance de charge déclassée ou le nombre de ballasts, selon le plus PETIT des deux nombres.

REMARQUE : Les commandes -8ANS, -RD277 and -RS-277 ont des ailettes qui doivent être enlevées avant de faire une installation à jumelage multiple. Les commandes -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS n’ont pas d’ailette à enlever pour les installations à jumelage multiple. Ne pas retirer les ailettes extérieures aux extrémités de l’alignement de contrôles multiples

b. C  apuchons de connexion : Préparation des fils. Pour les connexions avec capuchon, se conformer aux longueurs de dénudage recommandées pour les combinaisons de fils utilisés avec les capuchons fournis. REMARQUE : Les capuchons de connexion fournis s’utilisent avec des fils de cuivre seulement. Capuchon de connexion • Pour les fils de calibre 1,5 mm2 (14 AWG) ou 2,5 mm2 (12 AWG), enlever l’isolant sur 10 mm (3/8 po). • P  our les fils de calibre 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG), enlever l’isolant sur 11 mm (7/16 po). • U  tiliser pour raccorder un ou deux fils 1,5 mm2 (14 AWG) ou 2,5 mm2 (12 AWG) avec un fil de calibre 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG)

Le contrôle du milieu de l’unité a ses ailettes latérales enlevées des deux côtés

Installation AVERTISSEMENT – Danger d’électrocution – Pour éviter les chocs électriques, Identifier et retirer le fusible ou verrouiller le disjoncteur en position Ouvert (OFF) avant de procéder. Effectuer le câblage sous tension peut entraîner des lésions corporelles graves, voire la mort. 1. Couper l’alimentation au niveau de la boîte à fusibles ou du disjoncteur. 2. Avant d’installer le(s) contrôles, contrôler la présence de tout court-circuit. Après avoir coupé l’alimentation, installer les interrupteurs mécaniques entre le fil sous tension et la charge et rétablir l’alimentation. Si les lumières ne s’allument pas ou qu’un disjoncteur se déclenche, vérifier et rendre le câblage conforme au schéma approprié et faire une nouvelle vérification. N’installer les contrôles qu’après avoir vérifié qu’il n’y a pas de courtcircuit. La garantie sera annulée si une unité de contrôle est mise sous tension dans un circuit comportant un court-circuit. 3. Câbler les contrôles selon un des moyens décrits ci-après : a. B  ornes de raccordement : Couper ou dénuder les fils de la boîte murale à la longueur indiquée à la jauge de dénudage à l’endos du contrôle. • Bornes à pression : N’utiliser qu’avec des conducteurs de cuivre massif de calibre 1,5 mm2 (14 AWG). NE PAS utiliser de fil toronné ou torsadé. Insérer le conducteur jusqu’au fond de la borne. Pour dégager le fil, insérer un petit tournevis plat dans la fente sous la borne. et appliquer une pression en retirant le fil. OU

Laiton Sous tension

Bleu 1

Noir

Laiton

Sous tension

120 V~ 50/60 Hz

Bleu 1

Argent Noir

Vert

Vert Charge

120 V~ 50/60 Hz

Charge Mise à la terre

Neutre

Schéma de câblage 3

Schéma de câblage 4

Installation1 d’un seul gradateur avec neutre -F6AN-DV (120/277 V~)

Installation1 d’un seul sans neutre -8S-DV avec condensateur shunt en option2 (120-277 V~)

Gradateur Laiton Sous Argenté tension

Noir Orange Blanc

Bleu 1 Orange

Noir

Vert

120/277 V~ 50/60 Hz

Guide de dépannage Symptôme

Cause probable et action suggérée

Lumière / ventilateur ne répond pas à l’actionnement du bouton tactile du gradateur/interrupteur ou de la télécommande gradateur/ interrupteur

Sans alimentation • Disjoncteur ouvert (OFF) ou déclenché. Vérifier la présence éventuelle de court-circuit. • L’interrupteur FASS™ est ouvert (position « OFF »). Vérifier le gradateur/ interrupteur et toutes les télécommandes gradateur/interrupteur. Voir Remplacement de tubes/ampoules. Câblage • Fils court-circuités. S’assurer que la borne bleue n’est pas mise à la terre ou court-circuitée à d’autres fils. • Erreur de câblage. S’assurer que le câblage est conforme aux directives d’installation et aux schémas de câblage. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge.

Mise à la terre

Neutre

Noir Orange Blanc

Mise à la terre Neutre

Interrupteur Laiton

La charge est en dessous de la charge minimale exigée • S’assurer que la charge connectée est conforme aux exigences minimales pour cette commande. Voir les Spécifications de charge. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge.

Bleu 1

Sous tension

Noir

Optionnel

Vert Charge

120-277 V~ 50/60 Hz

Condensateur shunt2

Mise à la terre

Ampoules brûlées ou absentes • Remplacer ou installer les ampoules.

Neutre

Schéma de câblage 5 Installation3 à emplacements multiples sans neutre Gradateur -6D, -10D with -RD (120 V~) Gradateur à distance / gradateur3

Gradateur à distance / gradateur3

Gradateur3 /  gradateur à distance

Laiton

Laiton

Laiton

Bleu

Noir

Noir

Vert

120 V~ 50/60 Hz

Bleu

Vert

Ampoules à diodes • Si des ampoules à diodes sont utilisées, les remplacer par des ampoules d’un autre type.

Noir

Réglage de ventilateur • Assurez-vous que le ventilateur est réglé, par sa chaîne à tirette, à sa vitesse maximale.

REMARQUE : Le gradateur peut être installé à n’importe quel emplacement dans le circuit.

Bleu

Le contrôle de ventilateur n’est pas relié à un type de charge approprié • Assurez-vous que seulement un ventilateur à pales (moteur biphasé avec condensateur relié en permanence) de courant nominal de 2 A ou moins est relié au contrôle. • Assurez-vous qu’aucune charge d’éclairage (luminaires) n’est raccordée au contrôle.

Vert Charge

Mise à la terre

Mise à la terre

Mise à la terre

Neutre

Pour installation d’une unique et à multiples   Voir schémas de câblage. 4. Repousser tous les fils dans le boîtier mural et visser légèrement le contrôle au boîtier à l’aide des vis de montage fournies. Ne pas coincer les fils. 5. Attacher l’adaptateur de la plaque murale et la plaque murale Claro® ou Satin Colors® de Lutron®. Voir le Schéma d’assemblage. a. Installer l’adaptateur de la plaque murale sur le devant du/des contrôle(s).

Les ailettes entre tous les contrôles adjacents sont enlevées

Gradateur / interrupteur / commande de vitesse de ventilateur

Interrupteur

Sous tension

Visser fermement le capuchon de connexion

Installation1 d’un seul avec neutre -6NA, -10ND, -2ANF et -8ANS (120 V~)

Installation1 d’un seul sans neutre Interrupteur -6D, -10D (120 V~)

b. Serrer les vis de montage du contrôle jusqu’à ce que l’adaptateur du boîtier mural soit à égalité du mur (ne pas trop serrer). c. Enclencher la plaque murale sur l’adaptateur et s’assurer que le contrôle est bien aligné. d. Si les contrôles sont mal alignés, desserrer les vis de montage en conséquence. 6. Rétablir l’alimentation. Vérifier si le fonctionnement local est correct. Voir la feuille de Fonctionnement du gradateur / commande de vitesse de ventilateur ou Fonctionnement du interrupteur.

Schéma d’assemblage Adaptateur Plaque de plaque murale Vis de murale montage Vis de des montage de contrôles l’adaptateur

Schéma de câblage 6

Installation3 à emplacements multiples avec neutre4 -6NA, -10ND, -2ANF avec RD-RD, -8ANS avec RD-RS (120 V~) Gradateur à distance ou interrupteur à distance Laiton

Sous tension

Noir

Laiton

Gradateur / interrupteur / commande de vitesse de ventilateur

Bleu

Noir

Vert

120 V~ 50/60 Hz

Laiton Argent Noir

Vert

Mise à la terre

Bleu

Vert

Mise à la terre

Charge

La charge scintillent ou bouton tactile ne fonctionne pas, même si la charge est supérieure à 40 W (-8S-DV seulement)

Courant de fuite • Installer un condensateur shunt. Voir le Schéma de câblage 4 ou 8.

Les lumières s’allument et s’éteignent sans arrêt ou à l’actionnement du bouton tactile, les lumières s’allument et puis s’éteignent

La charge est de puissance inférieure au minimum requis • Augmenter la charge au-dessus du minimum requis pour ce contrôle. Voir Spécifications de charge. • Pour le interrupteur -8S-DV, ajouter un condensateur shunt. Voir le Schéma de câblage 4 ou 8. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge.

La charge scintillent (-8S-DV seulement)

La charge est de puissance inférieure au minimum requis • Augmenter la charge au-dessus du minimum requis pour ce contrôle. Voir Spécifications de charge. • Installer un condensateur shunt. Voir le Schéma de câblage 4 ou 8.

Lumières ne s’allument pas ON / OFF à partir d’un clavier

Programmation inadéquate • Programmer conformément au Guide de configuration du système.

Mise à la terre

Neutre

Schéma de câblage 7 Installation3 de gradateurs à emplacements multiples avec neutre4 Gradateur -F6AN-DV avec gradateur à distance -RD ou -RD-277 (120/277 V~) Gradateur à distance

Gradateur à distance

Laiton/ Rouge

Laiton/ Rouge

Sous tension

Noir 120/277 V~ 50/60 Hz

Bleu

Bleu

Vert

Noir

REMARQUE : Le gradateur principal doit être raccordé à la charge.

Gradateur

Laiton Argenté

Mise à la terre

Noir

Vert Mise à la terre

Bleu Orange

Noir Orange Blanc

Vert Mise à la terre

Noir Orange Blanc

Neutre

Hors de la portée RF • Rapprocher à moins de 9 m (30 pi) d’un répétiteur de signal RF. Câblage • Fils court-circuités. S’assurer que la borne bleue n’est pas mise à la terre ou court-circuitée à d’autres fils. • Erreur de câblage. S’assurer que le câblage est conforme aux directives d’installation et aux schémas de câblage.

Schéma de câblage 8 Installation3 à emplacements multiples sans neutre Interrupteur -8S-DV avec interrupteur à distance -RS ou -RS-277 et condensateur shunt en option2 (120-277 V~) Interrupteur à distance / interrupteur3 Laiton/ Rouge Sous tension Noir 120-277 V~ 50/60 Hz

Boîtier mural Inclus :

Bleu

Gradateur à distance ou interrupteur à distance

REMARQUE : Le gradateur/interrupteur principal doit être raccordé à la charge.

Ballast/pilote de lampe à diodes Lutron®

Veuillez lire avant l’installation *C  ommande de vitesse de ventilateur : * Interrupteurs à distance : RRD-2ANF (120 V~ 50 / 60 Hz) RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) * Gradateurs à distance : RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz)

Schéma de câblage 2

Schéma de câblage 1

Ballast/pilote de lampe à diodes Lutron®

Gradateurs style décorateur Maestro® RF

* Gradateur : RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Interrupteur : RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz)

• B  ornes à vis : N’utiliser qu’avec des conducteurs de cuivre massif de calibre 2,5 mm2 (12 AWG) ou 1,5 mm2 (14 AWG). NE PAS utiliser de fil multibrins ou toronné. Enrouler le conducteur sous la tête de la vis de la borne. Serrer au couple de 0,55 N•m (5 lb-po).

Ballast/pilote de lampe à diodes Lutron®

Installations à jumelage multiple Dans les installations à jumelage multiple, plusieurs commandes sont regroupées horizontalement dans un boîtier mural à jumelage multiple. Lorsque des commandes sont regroupées dans un boîtier mural, le déclassement est requis. Ceci ne s’applique pas aux commandedes de vitesse des ventilateurs et gradateurs/ interrupteurs à distance. Tableau de déclassement

Ballast/pilote de lampe à diodes Lutron®

Français Directives d’installation

Bleu

Vert

Interrupteur à distance / interrupteur3

Interrupteur3 / interrupteur à distance

Laiton/ Rouge

Laiton/ Rouge

Noir

Bleu

Vert

Noir

Bleu

REMARQUE : Le interrupteur peut être installé à n’importe quel emplacement dans le circuit.

Mise à la terre

Dissipation de la commande à semi-conducteurs • Les gradateurs/interrupteurs /commande de vitesse de ventilateur à semi-conducteurs dissipent à l’intérieur environ 2 % de la charge totale raccordée. Il est normal qu’ils soient chauds au toucher lorsqu’ils sont en service.

REMARQUE : Pour des suggestions additionnelles de dépistage de défauts, se référer au guide de configuration. Optionnel

Vert Charge

Mise à la terre

La plaque murale est chaude

Mise à la terre

Condensateur shunt2

Neutre Commande

Capuchons de connexion (1 ou 5) Vis de montage (2)

Adaptateur de plaque murale et plaque murale vendus séparément.

Remplacement de tubes/ ampoules AVERTISSEMENT – Danger d’électrocution – Pour toute autre procédure que le simple remplacement des tubes/ampoules, l’alimentation doit être coupée au panneau de distribution. Effectuer tout travail avec le système sous tension peut entraîner des lésions corporelles graves, voire la mort. Pour remplacer les tubes/ampoules sans danger, couper l’alimentation des appareils d’éclairage en plaçant l’interrupteur FASS™ du gradateur/interrupteur et de tous les gradateurs/interrupteurs à distance en position OFF.

1P  our les installations à un seul emplacement de commande, serrer la borne bleue sans y relier de fil. NE connecter aucun des fils, ou fil de mise à la terre à la borne bleue. 2 Le condensateur shunt doit être installé à l’intérieur du boîtier de l’appareil d’éclairage ou dans un boîtier de jonction séparé. 3 Installer un (1) seulement gradateur/interrupteur / commandes de vitesse de ventilateurs par circuit. Un circuit de gradateur/ interrupteur / commande de vitesse de ventilateur peut comprendre jusqu’à 9 contrôles gradateur/interrupteur / commande de vitesse de ventilateur à distance. La longueur permise du fil bleu est de 76 m (250 pi). 4 Les gradateurs / interrupteurs / commandes de vitesse de ventilateurs avec fil neutre doivent être connectés du côté charge d’une installation à emplacement multiple.

Fonctionnement du gradateur /  commande de vitesse de ventilateur

Gradateur montré

Fonctionnement du interrupteur

Voyants d’état (-F6AN-DV seulement) Indique le niveau d’éclairage et émet une lueur discrète de veilleuse lorsque la charge est coupée Bouton touche Toucher pour allumer/éteindre

Voyant d’état (-8S-DV seulement) Indique l’état de l’appareil d’éclairage et émet une lueur discrète de veilleuse lorsque la charge est coupée

Bouton d’actionnement à bascule du gradateur Appuyer pour augmenter l’intensité d’éclairage ou augmenter la vitesse Appuyer pour diminuer l’intensité d’éclairage ou diminuer la vitesse

Bouton touche Toucher pour allumer/éteindre

FASS™ Interrupteur de Service à Accès Frontal

FASS™ Interrupteur de Service à Accès Frontal

-RD-277 ou -RS-277 seulement OR OFF

ON

Rappel des réglages d’usine des gradateurs/interrupteurs REMARQUE : Le rappel du gradateur / interrupteur /commandes de vitesse de ventilateurs à ses réglages d’usine le retirera du système et effacera toute sa programmation. Étape 1 : T  aper trois fois du doigt sur le bouton tactile d’un contrôle et garder le doigt appuyé sur le bouton après la troisième tape. Étape 2 : G  arder le bouton appuyé durant environ 3 secondes, jusqu’à ce que les voyants du gradateur débutent une séquence d’illumination de va-et-vient rapide ou que le voyant DEL du interrupteur se mette à clignoter rapidement Étape 3 : R  elâcher le bouton et refaire immédiatement trois tapes rapides sur le bouton. Les voyants du gradateur débuteront une séquence d’illumination de va-et-vient lente. Le voyant DEL du interrupteur clignotera lentement. Le contrôle est alors remis à ses réglages d’usine et doit être reprogrammé dans le système. Garantie : voir la garantie incluse avec le produit ou visitez : www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, et ) sont des marques de commerce déposées et RadioRA 2, Compact SE et FASS sont des marques de commerce de Lutron Electronics Co., Inc. NEC est une marque de commerce déposée de National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc.

Ao combinar controles em uma caixa de embutir, é preciso reduzir a carga. Isso não é necessário para controles de velocidade de ventilador e dimmers / interruptores remotos. Tabela de redução de carga Controle

Especificações de carga Controle -6D1

-6NA1

-10D1

Tipo de carga Carga mín. Carga máx. Incand.

50 W

600 W

BTM2

50 W / VA

450 W /  600 VA

Incand. / BTE2

5W

600 W

BTM2

5 W / VA

450 W /  600 VA

Incand.

50 W

1 000 W

BTM

50 W / VA

800 W /  1 000 VA

Incand.

10 W

1 000 W

BTM2

10 W / VA

800 W /  1 000 VA

0,05 A

6A

1 balastro

60 balastros

0,083 A

2A

2

-10ND1

-F6AN-DV3, 4, 5 Fluorecente /  LED de 3 fios Ventilador de teto

-2ANF6 -8ANS7

8, 9

-8S-DV

Iluminação

10 W / VA

8A

Motor

0,08 A

1/4 HP 5,8 A

Iluminação

40 W / VA

8A

0,4 A

1/10 HP 3A

Motor

-RD10

Consulte dimmer

10

-RS

Consulte interruptor 11

-RD-277

Consulte dimmer

-RS-27711

Consulte interruptor

8,3 A

1 Tipo de carga de dimmer: Os controles -6D, -10D e -10ND só devem ser utilizados com cargas incandescentes, magnéticas de baixa tensão ou de tungstênio-halogênio instaladas permanentemente.  O controle -6NA só deve ser utilizado com cargas incandescentes, eletrônicos de baixa tensão, magnéticas de baixa tensão ou de tungstênio-halogênio instaladas permanentemente.  Não instale dimmers para comandar tomadas ou aparelhos motorizados. Não é permitido misturar tipos de carga incandescente, halogênio, BTM ou BTE em um dimmer. 2 Aplicações de baixa tensão: Use os modelos -6D, -10D e -10ND somente com transformadores magnéticos (núcleo e bobina) de baixa tensão. Não devem ser utilizados com transformadores eletrônicos (transistorizados) de baixa tensão.  Use o modelo -6NA com dimerizáveis transformadores eletrônicos (transistorizados) ou magnéticos (núcleo e bobina) de baixa tensão.  El funcionamiento de un circuito de bajo voltaje sin lámparas o con lámparas que no funcionan puede resultar en el sobrecalentamiento del transformador y fallas prematuras. Lutron recomienda firmemente lo siguiente: a. Não use circuitos de baixa tensão sem lâmpadas boas. b. Substitua lâmpadas as queimadas o mais rápido possível. c. Use transformadores com proteção térmica ou enrolamentos primários com fusível para evitar falhas devido a sobrecorrentes. 3 Dimmer de carga tipo fluorescente: -F6AN-DV foi projetado para uso com controles de balastros fluorescentes ou comandos de LEDs com voltagem de linha de 120 V~ ou 227 V~ de três cabos instalados permanentemente. Use somente com Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, ou EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). NÃO use com qualquer outro balastrobalastro ou comando. Não instale para controlar receptáculos ou aplicações operadas por motor. 4 Amplificador de potência – interfaces de carga: -6NA, -10ND, -F6AN-DV, e -8ANS pode ser usado para controlar amplificador de potência – interfaces de carga. Para obter uma lista de amplificador de potência – interfaces de carga compatíveis consulte Lutron P/N 369225. 5 Carga máxima: A caga máxima para o -F6AN-DV é a carga reduzida ou o número de balastros, o que for MENOR. 6 Aplicação de ventilador de teto (-2ANF): • Usar para controlar um ventilador de teto do tipo com pá (condensador permanente)*. • Usar a corrente de tração do ventilador de teto para programar sua velocidade para a mais alta*. • Não usar para controlar ventiladores que usam motores (i.e. ventiladores de exaustão de banheiro)*. • Não usar para controlar ventiladores que têm controles de velocidade integrados (i.e. ventiladores que têm controle remoto), a menos que o controle integrado tenha sido removido do ventilador de teto*. • Não conectar a nenhum outro equipamento operado por motor ou a qualquer outro tipo de carga de iluminação. • Não usar para controlar uma carga de iluminação de ventilador (i.e. kit de luz). 7 Tipo de carga do interruptor -8ANS: -8ANS é um tipo projetados para uso com todas as cargas incandescentes, magnéticas de baixa tensão, eletrônicos de baixa tensão ou de fluorescentes instaladas permanentemente e com cargas de motor de até 1/4 HP (5,8 A). 8 Tipo de carga do interruptor -8S-DV: -8S-DV foi projetado para uso com cargas incandescentes permanentemente instaladas de 120 V~, baixa voltagem magnética, baixa voltagem eletrônica ou cargas de motores; ou cargas fluorescentes ou baixa voltagem magnética de 277 V~. 9 Condensador Shunt (incluído): Algumas instalações do -8S-DV podem exigir o uso de um condensador shunt. Isto é necessário para tipos de cargas sensíveis à corrente de fuga (ou seja, balastros fluorescentes). Se carga tremula, instale um condensador shunt. Para a instalação do condensador shunt, consulte o Esquema de ligações elétricas 4 ou 8. 10  Dimmer / interruptor remoto 120 V~: -RD e -RS foram projetados para uso com dimmers / interruptores 120 V~. 11  Dimmer / interruptor remoto 277 V~: -RD-277 e -RS-277 foram projetados para uso com dimmers/ interruptores 277 V~. NÃO use com cargas de motor.

*Condições de teste de consumo normal de energia: Dimmer / Switch / Controle de velocidade de ventilador: 0,6 W (Carga desligada, modo luz noturna habilitado.) Dimmer / Interruptor remoto: 0 W (Carga desligada.)

-6D

Dimmer

Interruptor -6NA

-10D, -10ND

Dimmer remoto

Interruptour Controle de remoto velocidade de ventilador

Notas importantes AVISO – Perigo de imobilização – Para evitar o risco de imobilização, ferimentos graves ou morte, estes controles não devem ser usados para controlar equipamentos que não estão visíveis a partir de todos os locais de controle ou que podem criar situações perigosas, como imobilização, caso seja operado acidentalmente. Exemplos de equipamentos que não devem ser operados por estes controles incluem (mas não se limitam a) portões motorizados, portões de garagem, portões industriais, fornos de microondas, etc. É de responsabilidade de quem instala garantir que o equipamento que está sendo controlado esteja visível de cada local de controle e que somente equipamentos adequados sejam conectados a estes controles. Proceder de maneira contrária poderá causar morte ou ferimentos graves. Códigos: Instale de acordo com os códigos elétricos locais e nacionais. Aterramento: Se não houver uma “forma de aterramento” dentro da caixa de embutir, o Código Nacional de Eletricidade de 2011 (2011 National Electrical Code ® - NEC ®) permite que um controle seja instalado como um substituto, se 1) um espelho não metálico e não combustível for usado com parafusos não metálicos ou 2) o circuito for protegido por um interruptor diferencial por falha no aterramento (GFCI). Ao instalar um controle de acordo com esses métodos, tampe ou remova o fio verde antes de parafusar o controle na caixa de embutir. Neutro: Os modelos -6NA, -10ND, -F6AN-DV, -2ANF, e -8ANS exigem um condutor neutro na caixa de embutir, onde devem ser instalados o dimmer/ interruptor/controles de ventilador. Se não houver um condutor neutro na caixa de embutir, procure um eletricista autorizado para instalá-lo. Ambiente: Temperatura ambiente de trabalho: 0 °C a 40 °C (32 °F to 104 °F), 0% a 90% de umidade, sem condensação. Uso somente interior. Espaçamento: Se for instalar um controle sobre o outro, mantenha um espaço vertical entre eles de pelo menos 114 mm (4 ½ in). Espelhos: os modelos Lutron® Claro® e Satin Colors® são recomendados pela variedade de cores e pelo design. Não pinte os controles ou espelhos. Limpeza: Para limpar, passe um pano limpo úmido. NÃO use qualquer solução química de limpeza. Caixa de embutir: A Lutron recomenda o uso de caixas com 89 mm (3 ½ in) de profundidade para facilitar a instalação. É possível instalar vários controles em uma mesma caixa de instalação embutida. Consulte o Tabela de redução de carga. Dimmers / interruptores remotos: Use somente dimmers remotos (-RD / -RD-277) e interruptores remotos (-RS / -RS-277) com dimmers / interruptores. Podem ser usados até 9 -RD / -RD-277 or -RS / -RS-277 com dimmers ou interruptores. Interruptores mecânicos de 3 ou 4 vias não funcionarão. Localização dos dispositivos de RF: Os dimmers / interruptores e controles de velocidade de ventilador de RF devem estar a uma distância máxima de 9 m (30 pés) de um repetidor de sinal de RF. Os interruptores / dimmers remotos não precisam estar dentro de limites específicos em relação a um repetidor. Para sistemas com repetidor de sinal de RF, os dimmers / interruptores / controles de velocidade de ventilador de RF não podem ser controlados pelo sistema enquanto não estiverem programados de acordo com o Guia de configuração do sistema.

Assistência técnica: Brasil: +55 (11) 3257-6745 (Segunda-feira–Sexta-feira 8:30 to 17:30 BRT) E.U.A. / Canadá: 1.800.523.9466 | México: +1.888.235.2910 | Outros países: +1.610.282.3800 24 horas por dia, 7 dias por semana www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012

-F6AN-DV*

-2ANF

-8ANS

Tipo de carga

Interruptor Latão Preto

Instalação1 em um único local com neutro -F6AN-DV (120/277 V~)

500 W

400 W

BTM

400 W /  500 VA

300 W /  400 VA

NOTA: Os conectores de cabo fornecidos são adequados somente para cabos de cobre.

Incand./ BTE

500 W

400 W

Conector de cabo:

BTM

400 W /  500 VA

300 W /  400 VA

Incand.

800 W

650 W

• R  emova 10 mm (3/8 pol) de isolante do fio 1,5 mm2 (14 AWG) ou do fio 2,5 mm2 (12 AWG).

BTM

600 W /  800 VA

500 W /  650 VA

5A

3,5 A

50 balastros

35 balastros

Ventilador de teto

2A

2A

Iluminação

6,5 A

5A

Iluminação

8 A (2-grupos) 7 A (3-grupos)

Motor

1/10 HP 3A

-8S-DV

1/6 HP 4,4 A

Terra

Carga

Sintoma

Causa provável e ação

As luz ou ventilador não ACENDEM/APAGAM quando a chave seletora no dimmer / interruptor / controle de velocidade de ventilador ou dimmer / interruptor remoto é pressionada

Não há alimentação. • Disjuntor DESLIGADO ou aberto. Verifique se há curtos-circuitos. • FASS™ está na posição OFF. Mude FASS™ para a posição ON. Verifique o dimmer / interruptor / controle de velocidade de ventilador, bem como todos os dimmers / interruptores remotos Consulte Substituição da lâmpada.

Terra

Neutro Neutro

Esquema de ligações 4 Instalação1 em um único local sem neutro -8S-DV com condensador shunt opcional2 (120-277 V~)

• R  emova 11 mm (7/16 pol) de isolante do fio 0,75 mm2 (18 AWG) ou do fio 1,0 mm2 (16 AWG). • U  se para unir um ou dois cabos 1,5 mm (14 AWG) ou 2,5 mm2 (12 AWG) com um cabo 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG). 2

Preto Laranja Branco

Azul1

Latão Prata

Vivo

Laranja

Preto

Verde

120/277 V~ 50/60 Hz

Interruptor Latão

Azul1

Vivo Preto

Preto Laranja Branco

Terra

Neutro

Condensador Shunt 2

Carga

120-277 V~ 50/60 Hz

Lâmpadas estão queimadas ou não estão instaladas • Substitua ou instale as lâmpadas.

Opcional

Verde

Lâmpadas de diodo • Se estiverem sendo usadas lâmpadas de diodo, substitua-as por lâmpadas sem diodo

Terra

Neutro

Programação do ventilador • Verifique se o ventilador está programado para sua mais alta velocidade usando a corrente de tração.

Esquema de ligações 5 Instalação3 em vários locais sem neutro -6D, -10D with -RD (120 V~) Dimmer remoto / dimmer 3

Gire com firmeza o conector de fiação

Dimmer remoto / dimmer 3 Latão

Azul

Latão Preto

Tipo de carga errada no controle de velocidade de ventilador • Confirme se apenas um único ventilador de pás giratórias de teto (motor com condensador permanente) classificado em 2 A ou menos está ligado ao controle. • Verifique se nenhuma carga de iluminação (i.e. kit de luz) está conectado ao controle.

Dimmer 3 /  dimmer remoto Latão

Azul

7A

NOTA: -8ANS, -RD-277 and -RS-277 possuem aletas que precisam ser removidas para instalações multigrupos. -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS não possuem abas que precisam ser removidas.

Não remova as abas externas nos controles na extremidade do grupo.

4. Coloque os cabos de volta na caixa de embutir e parafuse, sem apertar, o controle na caixa usando os parafusos fornecidos. Não amasse os cabos.

Azul

a. Instale o adaptador do espelho na frente do(s) controle(s). b. Aperte os parafusos de montagem do controle até que adaptador do espelho fique rente à parede (não aperte demais).

d. Se os controles estiverem desalinhados, afrouxe os parafusos de montagem apropriadamente

Instalação ATENÇÃO – Risco de choques – Para evitar o risco de choques elétricos, localize e remova o fusível ou trave o disjuntor na posição OFF (desligado) antes de prosseguir. Fazer instalação com a chave geral ligada pode resultar em lesões graves ou fatais. 1. DESLIGUE a alimentação na caixa de fusível ou no disjuntor. 2. Verifique a instalação quanto a curtos-circuitos antes de instalar o(s) controle(s). Com a alimentação DELSIGADA, instale interruptores mecânicos padrão entre quente e a carga. Restabeleça a alimentação. Se as lâmpadas e ventalidores não funcionar ou o disjuntor for desarmado, verifique a fiação. Corrija a fiação e verifique novamente. Instale os controles somente quando não houver curtos-circuitos. A garantia é invalidada se o controle foi acionado (ON) havendo um curto-circuito. 3. Conecte os cabos de acordo com uma das opções abaixo: a. T  erminais: Apare ou retire o isolamento dos fios da caixa de embutir no comprimento indicado pelo medidor de corte, na parte posterior do controle. • Terminais a pressão: Use apenas com o fio 1,5 mm2 (14 AWG) de cobre sólido. NÃO use cabos trançados ou torcidos. Insira os cabos completamente. Para soltar um cabo, insira uma chave de fenda pequena na ranhura abaixo do terminal a pressão. Pressione a chave de fenda enquanto puxa o cabo para fora. OU

6. Restabeleça a alimentação. Verifique se a operação local está correta. Consulte a Operação do dimmer / controle de velocidade de ventilador ou Operação do interruptor.

Preto

Verde

NOTA: O dimmer pode ser instalado em qualquer lugar do circuito.

Verde Carga

Terra

Terra

Terra

Neutro

Esquema de ligações 6 Instalação3 em vários locais com neutro4 -6NA e -10ND, -2ANF com RD-RD, -8ANS com RD-RS (120 V~)

5. Prenda o adaptador de espelho e o espelho Claro® ou Satin Colors® da Lutron®. Consulte o Diagrama de montagem.

c. Encaixe o espelho no adaptador e verifique se o controle está alinhado corretamente.

O controle no meio do grupo está com todas as abas removidas

Verde

120 V~ 50/60 Hz

Instalação em um só local ou vários locais consulte os esquema de ligações.

Preto

Dimmer remoto ou interruptor remoto

Dimmer remoto ou interruptor remoto

Latão

Latão

Azul

Preto

Preto

Verde

Terra

NOTA: O dimmer deve ser instalado no lado da carga do circuito.

Azul

Latão Prata

Azul

Preto

Verde

A carga tremula ou chave seletora não funciona, mesmo se a carga for superior a 40 W (somente -8S-DV)

Corrente de fuga • Instale um condensador shunt. Consulte o Esquema de ligações elétricas 4 ou 8.

A luz acende e apaga continuamente ou a luz acende (ON) quando a chave seletora é pressionada, apagando em seguida (OFF)

A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima de carga. Consulte as Especificações de carga. • Instale um condensador shunt com o -8S-DV. Consulte o Esquema de ligações elétricas 4 ou 8. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga.

A carga tremula (somente -8S-DV)

A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima de carga. Consulte as Especificações de carga. • Instale um condensador shunt. Consulte o Esquema de ligações elétricas 4 ou 8.

As luzes / ventiladores não acendem/apagam a partir de um teclado

Programação incorreta • Programe de acordo com o Guia de configuração do sistema.

Dimmer / Interruptor / Controle de velocidade de ventilador

Vivo 120 V~ 50/60 Hz

Verde

Terra

Carga

Terra

Neutro

Esquema de ligações 7 Instalação3 do interruptor em vários locais com neutro -F6AN-DV com -RD ou -RD-277 (120/277 V~) Dimmer remoto Latão/ Vermelho

Dimmer remoto Latão/ Vermelho

Azul

Azul

Latão Prata

Preto

Preto

Azul Laranja

Preto Laranja Branco

Preto Laranja Branco

Preto

Verde

Verde

Terra

Verde

Terra

Terra

Neutro

O espelho está quente

Instalação3 do interruptor em vários locais sem neutro -8S-DV com -RS ou -RS-277 e condensador shunt opcional2 (120-277 V~)

Diagrama de montagem Adaptador Espelho do espelho Parafusos de instalação Parafusos de montagem do do controle adaptador

Latão/ Vermelho Vivo Preto 120-277 V~ 50/60 Hz

Latão/ Vermelho

Azul

Verde

Preto

Azul

Verde

Latão/ Vermelho Preto

Azul

NOTA: O interruptor pode ser instalado em qualquer lugar do circuito.

Terra

(01) 07898525200097

Verde

Condensador Shunt 2

Terra

1 Ao usar controles em instalações de único local, aperte o terminal azul sem nenhum fio conectado. NÃO conecte o terminal

Controle

Conectores de cabos (1 ou 5)

Adaptador do espelho e espelho vendidos separadamente.

Parafusos de instalação (2)

Substituição de lâmpada AVISO – Perigo de choque – No caso de qualquer procedimento que não seja a troca rotineira de lâmpadas, o painel elétrico principal deverá estar desconectado da rede elétrica. Trabalhar com a rede ligada pode resultar em lesões graves ou fatais. Para sua segurança no caso de troca rotineira de lâmpadas, desligue a(s) luminária(s) movendo o interruptor FASS™ do dimmer / interruptor e de todos os interruptores / dimmers remotos para a posição OFF (desligado).

azul a nenhum outro fio nem ao terra. 2 O condensador shunt deve ser instalado no lado da luminária de carga ou em uma caixa J separada. 3 Instalação apenas um (1) dimmer / interruptor/ controle de velocidade de ventilador por circuito. Podem ser conectados no dimmer / interruptor / controle de velocidade de ventilador até 9 dimmers / interruptores remotos. O comprimento total do cabo do terminal azul pode chegar a 76 m (250 pés). 4 Os dimmers / interruptores / controles de velocidade de ventilador de fio neutro devem ser conectados no lado da carga da instalação em vários locais.

Operação do dimmer / controle de velocidade de ventilador 

LED de status (somente -8S-DV) Indica o status da luz; tem um brilho suave, como uma iluminação noturna, quando a carga está desligada

Chave seletora Toque para ligar/desligar

Chave seletora Toque para ligar/desligar

Controle de atenuação Pressione para aumentar a intensidade de luz ou para aumentar a velocidade Pressione para reduzir a intensidade de luz ou para reduzir a velocidade de ventilador

FASS™ Frente Acessível Serviço Interruptor

Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, e ) são marcas registradas e RadioRA 2, Compact SE e FASS são marcas registradass da Lutron Electronics Co., Inc. NEC é marca registrada da National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Brasil Ltda.

Modelo: RRD-6D

0839-11-6852

(01) 07898525200073 Modelo: RRD-10D

0839-11-6852

3283-10-0905

(01) 07898525200219

Modelo: RRD-8ANS

0839-11-6852

(01) 07898525200103 2854-10-0905 Modelo: RRD-8S-DV

Operação do interruptor

LEDs de status (somente -F6AN-DV) Indica a intensidade da luz; tem um brilho leve, como uma iluminação noturna, quando a carga está desligada

Dimmer mostrado

0839-11-6852 0145-11-0905

Modelo: RRD-10ND

Este equipamento opera em caráter (01) secundário, 07898525200110 Modelo: RRD-F6AN-DV isto é, não tem direito à proteção contra interferência prejudicial, mesmo de estaçoes do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário.

Opcional Carga

Terra

Modelo: MRF2-3BRL-L

Interruptor 3 / Interruptor remoto

Neutro

Caixa de embutir Incluído:

Interruptor remoto / interruptor 3

Dissipação de controle de estado sólido • Os dimmers / interruptores / controles de velocidade de ventiladores de estado sólido dissipam internamente cerca de 2% da carga total conectada. É normal que os dimmers / interruptores / controles de velocidade de ventiladores fiquem quentes durante o funcionamento.

NOTA: Consulteo guia de configuração do sistema para outras sugestões de solução de problemas.

Esquema de ligações 8 Interruptor remoto / interruptor 3

Fora da faixa de RF • Reposicione para estar dentro de um raio de 9 m (30 pés) de um repetidor de sinais de RF. Fiação • Cabos em curto. Verifique se o terminal azul não está conectado ao terra ou em curto com algum outro cabo. • Erro na fiação. Verifique se a fiação está de acordo com as instruções de instalação e os diagramas de conexão.

NOTA: O dimmer deve ser instalado no lado da carga do circuito.

Dimmer

Vivo 120/277 V~ 50/60 Hz

Fiação • Cabos em curto. Verifique se o terminal azul não está conectado ao terra ou em curto com algum outro cabo. • Erro na fiação. Verifique se a fiação está de acordo com as instruções de instalação e os diagramas de conexão. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga. A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima do controle. Consulte o Especificações de carga. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga.

Vivo

número de balastros, o que for MENOR.

Cada controle teve as abas internas removidas

Verde

120 V~ 50/60 Hz

Guia para resolução de problemas

Dimmer

* A caga máxima para o -F6AN-DV é a carga reduzida ou o

Azul1

Preto Carga

Esquema de ligações 3

Incand.

1/4 HP 5,8 A

Vivo

Verde

120 V~ 50/60 Hz

b. C  onectores de cabos: Prepare os cabos. Ao fazer conexões de cabos, siga o comprimento recomendado de desencape e as combinações para os conectores de cabo fornecidos

Meio do agrupamento

Motor

Latão Prata

Vivo

Extremo final do agrupamento

Fluorescente / LED de 3 fios.

Dimmer / Interruptor / Controle de velocidade de ventilador

Azul1

Comando da Lutron® do balastro/LED

Para o Guia de configuração do sistema e ferramentas, visite: www.lutron.com/radiora2



Instalação1 em um único local com neutro -6NA, -10ND, -2ANF e -8ANS (120 V~)

Instalação1 em um único local sem neutro -6D, -10D (120 V~)

• T  erminais parafusados: Use apenas com o fio 2,5 mm2 (12 AWG) ou 1,5 mm2 (14 AWG) de cobre sólido. NÃO use cabos trançados ou torcidos. Enrole o cabo em volta do terminal parafusado. Aperte bem com 0,55 N•m (5 pol-lb).

Comando da Lutron® do balastro/LED

*C  ontrole de velocidade de ventilador: * Interruptores remotos: RD-RS (120 V~ 50 / 60 Hz) RRD-2ANF (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) * Dimmers remotos: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz)

Em instalações multigrupos, vários controles são reunidos horizontalmente em uma mesma caixa de embutir.

Comando da Lutron® do balastro/LED

Por favor, leia antes de instalar

Tipo designer RF Maestro®

* Dimmer: RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Interruptor: RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz)

Esquema de ligações 2

Esquema de ligações 1

Instalações múltiplas

Comando da Lutron® do balastro/LED

Português Instruções de instalação

FASS™ Frente Acessível Serviço Interruptor

-RD-277 ou -RS-277 apenas OR OFF

ON

(01) 07898525200080

(01) 07898525200189

Restauração dos dimmers/interruptores para a configuração de fábrica NOTA: A restauração de um dimmer / interruptor / control de velocidade de ventiladore para a configuração de fábrica o removerá do sistema e apagará toda a programação Passo 1: T  oque três vezes na chave seletora de um controle. NÃO solte após o terceiro toque. Passo 2: M  antenha a chave seletora pressionada após o terceiro toque (por aproximadamente 3 segundos) até que os LEDs no dimmer comecem a piscar em sequência para cima e para baixo rapidamente ou o LED no interruptor pisque rapidamente. Passo 3: S  olte a chave seletora e, imediatamente, pressione-a três vezes novamente. Os LEDs no dimmer se deslocarão para cima e para baixo lentamente. O LED no interruptor piscará lentamente. O controle agora retornou à configuração de fábrica e precisa ser programado para um sistema. Garantia: Consulte a garantia que acompanha o produto ou visite: www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf