CEDULA JURIDICA 3-007-521568. -PLANTA DE CONJUNTO MECANICO. TRAMPA DE GRASA SANITARIO, VER DETALLE. (GREASE TRAP, SEE DETAIL).
1MB Größe 1 Downloads 0 vistas
HACIA DESFOGUE PLUVIAL (TO RAINWATER DISCHARGE POINT)

0

125

280

SIMBOLOGIA MECANICA (MECHANICAL SYMBOLOGY) CALLE EXISTENTE (EXISTING STREET) 3.3 4%

ACCESO (ACCESS)

ACERAS EXISTENTE (EXISTING SIDEWALKS) -26 DR Ø CS PV mm 0 15

TUBERIA PARA AGUA PLUVIAL EN P.V.C Ø INDICADO (RAINWATER PIPE P.V.C, Ø INDICATED

CASETA (SECURITY BOOTH)

TRAMPA DE GRASA SANITARIO, VER DETALLE (GREASE TRAP, SEE DETAIL)

BODEGA DFSE STORAGE ROOM DFSE

15

TANQUE PLUVIAL A COLOCAR VER DETALLE EN LAMINA SR-7.1 (RAINWATER TANK TO BE PLACED SEE DETAIL IN SHEET SR-7.1)

0 0 15

PVC SDR-26 150 mmØ

1.5 %

ARBOL EXISTENTE (EXISTING TREE)

EDIFICIO EXISTENTE A REMODELAR (EXISTING BUILDING TO BE REMODELED)

1.5

LABORATORIO DFSE LABORATORY DFSE

CAJA DE REGISTRO EXISTENTE (EXISTING INSPECTION CHAMBER)

%

6 R-2 SD Ø C PV mm 150

MODIFICACION 1

E-00319 FECHA

REVISO

--/--/--

OGB

MUSEO NACIONAL (NATIONAL MUSEUM) Tel (506) 2290 4070 Fax (506) 2290 7122 Oficentro Alquimia, 100 m Sur de la Liga de la Caña La Uruca, San José, Costa Rica www.estru.com

CAJA DE REGISTRO EXISTENTE (EXISTING INSPECTION CHAMBER)

NOTA : (NOTE :) 1

PLANTA DE CONJUNTO MECANICO (MECHANICAL GENERAL PLAN) ESCALA 1:250 (SCALE)

CONJUNTO GENERAL (GENERAL PLAN)

ACOTADO cm (DIMENSIONS IN cm)

EL TANQUE PLUVIAL DEBE INCLUIR DOS BOMBAS SUMERGIBLES CON CAPACIDAD DE 10 l/s 5HP CADA UNA MONOFASICAS (THE RAINWATER TANK MUST INCLUDED TWO SUBMERSIBLES PUMPS WITH A CAPACITY OF 10 l/s 5HP EACH, SINGLE-PHASE)

estru consult

CONSULTORESENINGENIERÍA

PROYECTO :

MAG MONITORING CENTER RETROFIT CONTENIDO -PLANTA DE CONJUNTO MECANICO -(MECHANICAL GENERAL PLAN)

INFORMACION REGISTRO PUBLICO PROPIETARIO: N° CATASTRO:

SERVICIO FITOSANITARIO DEL ESTADO CEDULA JURIDICA 3-007-521568 4-7745-75

FOLIO REAL:

4-23854-000

ESCALA

FECHA

INDICADAS

MARZO 2019

LAMINA

MR-1.1

A

B

C

D

E

F

G

H

SIMBOLOGIA MECANICA (MECHANICAL SYMBOLOGY)

I

TUBERIA PARA AGUAS NEGRAS, SDR 26, Ø INDICADO (WASTEWATER PIPE, SDR 26, INDICATED Ø )

1

TUBERIA PARA AGUA JABONOSAS, SDR 26,Ø INDICADO (SOAPY WATER PIPE, SDR 26 INDICATED Ø )

1 (GREASE TRAP TO BE BUILT)

(75 mmØ SDR- 26 P.V.C PIPE TO BE BUILT) 1.5%

TG

CR

CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

TG

TRAMPA DE GRASA SANITARIO, VER DETALLE (GREASE TRAP, SEE DETAIL) DIRECCION DE FLUJO (FLOW DIRECTION )

1.5%

3

15 31 19

1.5%

3

CAJA DE REGISTRO, VER DETALLE (INSPECTION CHAMBER, SEE DETAIL)

TUBERIA P.V.C 75 mmØ SDR-26 A CONSTRUIR (75 mmØ SDR- 26 P.V.C PIPE TO BE BUILT)

TUBERIA EXISTENTE (EXISTING PIPE)

CR

CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

CR

2

1.5%

2

TUBERIA PARA AGUAS NEGRAS EXISTENTE . (EXISTING WATEWATER PIPE )

TUBERIA P.V.C 75 mmØ SDR-26 A CONSTRUIR

TRAMPA DE GRASA A CONSTRUIR

TUBERIA P.V.C 100 mmØ SDR-26 A CONSTRUIR (100 mmØ SDR- 26 P.V.C PIPE TO BE BUILT)

(THE EXISTING SOAPY WATER OUTLET MUST BE USED)

1

MALLA ELECTROSOLDADA #2 (# 2 WELDED STEEL MESH)

1.5%

CR

1

(EXISTING INSPECTION CHAMBER, MUST BE CLEANED REPAIRED AND ITS PERFECT FUNCTIONALITY MUST BE ENSURED)

TUBO DE PVC DE 15cmØ ( 15 cm Ø P.V.C PIPE)

31

SE DEBE UTILIZAR SALIDA DE AGUAS JABONOSAS EXISTENTE

5

CAJA DE REGISTRO EXISTENTE. SE DEBE LIMPIAR REPARAR Y GARANTIZAR SU PERFECTA FUNCIONALIDAD

30

4

6

TUBO DE P.V.C DE 15 cm Ø

5

(15 CM Ø P.V.C PIPE)

6 15

SECCION 1-1 3 (SECTION 1-1)

31

7 8

TUBERIA EXISTENTE (EXISTING PIPE)

2 9

TUBERIA P.V.C 100 mmØ SDR-26 A CONSTRUIR

CAJA DE REGISTRO (INSPECTION CHAMBER) ESCALA 1:5 (SCALE)

ACOTADO cm (DIMENSIONS IN cm)

A CONSTRUIR (TO BE BUILT)

(100 mmØ SDR- 26 P.V.C PIPE TO BE BUILT)

10

1.5%

10

TAPA DE CONCRETO CON MALLA #2 @ 10cm TORNILLO 9 mmØ, CON TUERCA SOLDADA (0.9cmØ WELDED SCREW)

(CONCRETE LID WITH #2 BAR MESH @10 cm)

MODIFICACION 1

E-00319 FECHA

REVISO

--/--/--

OGB

7.5

TUBERIA EXISTENTE (EXISTING PIPE)

ESCALA 1:15 ACOTADO cm (DIMENSIONS IN cm) (SCALE)

11 CR

SALIDA (OUTLET)

NIVEL DE AGUA ( WATER LEVEL)

Tel (506) 2290 4070 Fax (506) 2290 7122 Oficentro Alquimia, 100 m Sur de la Liga de la Caña La Uruca, San José, Costa Rica www.estru.com

estru consult

CONSULTORESENINGENIERÍA

A TANQUE SEPTICO EXISTENTE. VER UBICACION EN LAMINA C1.1 (TO EXISTING SEPTIC TANK. SEE LOCATION IN SHEET C1.1)

A

B

C

D

F

E

PLANTA MECANICA DE AGUAS NEGRAS Y JABONOSAS 1 (SOAPY WATER AND WASTEWATER MECHANICAL PLAN) ESCALA 1:50 (SCALE)

ACOTADO cm (DIMENSIONS IN cm)

G

H

35

PROYECTO :

MAG MONITORING CENTER RETROFIT

20

3%

7.5

TUBERIA P.V.C 100 mmØ SDR-26 A CONSTRUIR (100 mmØ SDR- 26 P.V.C PIPE TO BE BUILT)

BLOQUES DE 12x20x40 cm CON LAS CELDAS RELLENAS DE CONCRETO o PARED CHORREADA EN SITIO DE 10cm ESPESOR MINIMO (12x20x40 cm CMU WITH ALL CELLS CONCRETE FILLED OR = 10 cm MIN CONCRETE WALL)

25

5%

1.

CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

INLET

59.5

REPELLADO Y LUJADO (PLASTERED AND POLISHED FINISH)

52

11

BASE DE CONCRETO POBRE (LOW STRENGTH CONCRETE)

55

I

TRAMPA DE GRASA 4 (GREASE TRAP) ESCALA 1:10 (SCALE)

ACOTADO cm (DIMENSIONS IN cm)

CONTENIDO -PLANTA MECANICA DE AGUAS NEGRAS Y JABONOSAS -(SOAPY WATER AND WASTEWATER MECHANICAL PLAN)

INFORMACION REGISTRO PUBLICO PROPIETARIO: N° CATASTRO:

SERVICIO FITOSANITARIO DEL ESTADO CEDULA JURIDICA 3-007-521568 4-7745-75

FOLIO REAL:

4-23854-000

ESCALA

FECHA

INDICADAS

MARZO 2019

LAMINA

MR-1.2

A

B

C

D

E

F

G

H

I

1

1 TUBERIA PVC 12.7 mmØ SDR-17.5 A CONSTRUIR ( 12.7 mm Ø SDR-17.5 P.V.C PIPE TO BE BUILT)

TUBERIA EXISTENTE (EXISTING PIPE)

2

2 TUBERIA PVC 12.7 mmØ SDR-17.5 A CONSTRUIR ( 12.7 mm Ø SDR-17.5 P.V.C PIPE TO BE BUILT)

TUBERIA PVC 12.7 mmØ SDR-17.5 A CONSTRUIR ( 12.7 mm Ø SDR-17.5 P.V.C PIPE TO BE BUILT)

3

3 (SE DEBE CONECTAR A SALIDA DE AGUA EXISTENTE) (MUST BE CONNECTED TO EXISTING WATER OUTLET)

4

SE DEBE CONECTAR A SALIDA DE AGUA EXISTENTE

SIMBOLOGIA MECANICA (MECHANICAL SYMBOLOGY)

(MUST BE CONNECTED TO EXISTING WATER OUTLET)

TUBERIA PARA AGUA POTABLE EXISTENTE (EXISTING DRINKING WATER PIPE ) TUBERIA PARA AGUA POTABLE TO BUILD (DRINKING WATER PIPE )

5

6

(TUBERIA EXISTENTE) (EXISTING PIPE)

7 8 TUBERIA EXISTENTE (EXISTING PIPE)

9

10

10 MODIFICACION

11

11 TUBERIA EXISTENTE (EXISTING PIPE)

1

E-00319 FECHA

REVISO

--/--/--

Tel (506) 2290 4070 Fax (506) 2290 7122 Oficentro Alquimia, 100 m Sur de la Liga de la Caña La Uruca, San José, Costa Rica www.estru.com

OGB

estru consult

CONSULTORESENINGENIERÍA

PROYECTO :

MAG MONITORING CENTER RETROFIT

A

B

C

D

F

E

PLANTA MECANICA DE AGUA POTABLE 1 (POTABLE WATER MECHANICAL PLAN) ESCALA 1:50 (SCALE)

ACOTADO cm (DIMENSIONS IN cm)

G

H

I

CONTENIDO -PLANTA MECANICA DE AGUA POTABLE (POTABLE WATER MECHANICAL PLAN)

INFORMACION REGISTRO PUBLICO PROPIETARIO: N° CATASTRO:

SERVICIO FITOSANITARIO DEL ESTADO CEDULA JURIDICA 3-007-521568 4-7745-75

FOLIO REAL:

4-23854-000

ESCALA

FECHA

INDICADAS

MARZO 2019

LAMINA

MR-1.3

A

F

C PVC 150 mmØ A CONSTRUIR (150 mm Ø P.V.C PIPE TO BE BUILT)

SIMBOLOGIA MECANICA (MECHANICAL SYMBOLOGY)

I PVC 150 mmØ A CONSTRUIR (150 mm Ø P.V.C PIPE TO BE BUILT)

TUBERIA PARA AGUA PLUVIAL EN P.V.C Ø INDICADO (RAINWATER PIPE P.V.C, Ø INDICATED

1

A TANQUE PLUVIAL A CONSTRUIR (TO RAINWATER TANK TO BE BUILD)

% 1.5

CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

1.5 % P.V.C 100 mmØ A CONSTRUIR (100 mm Ø P.V.C PIPE TO BE BUILT)

BAP 10 cmØ A CONSTRUIR (10 cm Ø BAP PIPE TO BE BUILT)

CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

1.5 %

1.5 % BAP 100 mmØ A CONSTRUIR (100 mm Ø BAP PIPE TO BE BUILT)

PVC 100 mmØ A CONSTRUIR (100 mm Ø P.V.C PIPE TO BE BUILT)

HACIA CUNETA EXISTENTE (TO EXISTING DITCH)

(INSPECTION REGISTER TO BE BUILT)

C

3 HACIA CUNETA EXISTENTE (TO EXISTING DITCH)

CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

BAP 100 mmØ A CONSTRUIR

(100 mm Ø BAP PIPE TO BE BUILT)

(100 mm Ø BAP PIPE TO BE BUILT)

3

P.V.C 100 mmØ CON DIFUSOR (100 mm Ø P.V.C PIPE WITH DIFFUSER)

PVC 100 mmØ CON DIFUSOR (100 mm Ø P.V.C PIPE WITH DIFFUSER)

CUNETA EXISTENTE A TAPAR (EXISTING DITCH TO BE COVER)

BAP 100 mmØ A CONSTRUIR

(TO EXISTING DITCH)

(100 mm Ø BAP PIPE TO BE BUILT)

15%

G

HACIA CUNETA EXISTENTE

BAP 100 mmØ A CONSTRUIR

BAP 100 mmØ A CONSTRUIR (100 mm Ø BAP PIPE TO BE BUILT)

DIRECCION DE FLUJO (FLOW DIRECTION )

CAJA DE REGISTRO EXISTENTE (EXISTING INSPECTION REGISTER)

CAJA DE REGISTRO A CONSTRUIR

CAJA DE REGISTRO EXISTENTE (EXISTING INSPECTION REGISTER)

2

CAJA DE REGISTROPLUVIAL, VER DETALLE (RAINWATER INSPECTION CHAMBER, SEE DETAIL)

CR

15%

VIENE DE PLANTA ALTA BAP 100 mmØ A CONSTRUIR (BAP 100 mmØ COMES FROM THE SECOND LEVEL TO BE BUILT)

VIENE DE PLANTA ALTA BAP 100 mmØ A CONSTRUIR (BAP 100 mmØ COMES FROM THE SECOND LEVEL TO BE BUILT)

BAP 100 mmØ A CONSTRUIR ( 100 mmØ BAP PIPE TO BE BUILT)

CUNETA EXISTENTE A TAPAR (EXISTING DITCH TO BE COVER)

19.3%

15%

15%

BAP 100 mmØ A CONSTRUIR (100 mm Ø BAP PIPE TO BE BUILT)

CUNETA EXISTENTE A TAPAR (EXISTING DITCH TO BE COVER)

HACIA CUNETA EXISTENTE (TO EXISTING DITCH)

9

CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

15.3% VIENE DE PLANTA ALTA BAP 100 mmØ A CONSTRUIR CAJA DE REGISTRO A CONSTRUIR (INSPECTION CHAMBER TO BE BUILT)

BAP 100 mmØ A CONSTRUIR (100 mm Ø BAP PIPE TO BE BUILT)

15%

HACIA CUNETA EXISTENTE (TO EXISTING DITCH)

VIENE DE PLANTA ALTA BAP 100 mmØ A CONSTRUIR (BAP 100 mmØ COMES FROM THE SECOND LEVEL TO BE BUILT)

(BAP 100 mmØ COMES FROM THE SECOND LEVEL TO BE BUILT)

PVC 100 mmØ CON DIFUSOR

PVC 100 mmØ CON DIFUSOR

(100 mm Ø P.V.C PIPE WITH DIFFUSER)

(100 mm Ø P.V.C PIPE WITH DIFFUSER)

9

BAP 100 mmØ A CONSTRUIR (100 mm Ø BAP PIPE TO BE BUILT)

CUNETA EXISTENTE A TAPAR (EXISTING DITCH TO BE COVER)

2

BAP 100 mmØ A CONSTRUIR (100 mm Ø BAP PIPE TO BE BUILT)

PLANTA MECANICA PLUVIAL (RAINWATER SYSTEM PLAN) ESCALA 1:50 (SCALE)

ACOTADO cm (DIMENSIONS IN cm)

SEGUNDO NIVEL (SECOND LEVEL)

15.3%

MODIFICACION CR

CUNETA EXISTENTE ANGULAR 2.5X2.5X0.30 cm

11

E6013

3

20-200

(EXISTING DITCH)

1

ANGULAR 5X5X0.50 cm

E6013

1

ANGULAR 5X5X0.50 cm

Tel (506) 2290 4070 Fax (506) 2290 7122 Oficentro Alquimia, 100 m Sur de la Liga de la Caña La Uruca, San José, Costa Rica www.estru.com

N. 0.0

30

N. 0.0

1

PLANTA MECANICA PLUVIAL (RAINWATER SYSTEM PLAN) ESCALA 1:50 (SCALE)

PRIMER NIVEL (FIRST LEVEL)

E6013

ANGULAR 5X5X0.50 cm 3 20-200

ACOTADO cm (DIMENSIONS IN cm)

1

1

ESCALA 1:10 (SCALE)

ACOTADO cm (DIMENSIONS IN cm)

OGB

consult

CONSULTORESENINGENIERÍA

MAG MONITORING CENTER RETROFIT

40

CUNETA EXISTENTE

30

estru

PROYECTO :

ANGULAR 2.5X2.5X0.30 cm

(EXISTING DITCH)

LAMINA DE ACERO EXPANDIDA AC 208-0.50 cm (EXPANDED STEEL SHEET AC 208-0.50 cm)

DETALLE DE TAPA A COLOCAR EN CUNETA EXISTENTE (LID TO BE PLACED IN EXISTING DITCH)

--/--/--

10

ANGULAR 5X5X0.50 cm

ANGULAR 2.5X2.5X0.30 cm

REVISO

3 20-200

10

LAMINA DE ACERO EXPANDIDA ACL 08-0.50 (EXPANDED STEEL SHEET ACL 08-0.50)

E-00319 FECHA

CONTENIDO -PLANTA MECANICA DE AGUA PLUVIALE -(RAINWATER SYSTEM PLAN)

INFORMACION REGISTRO PUBLICO PROPIETARIO:

SECCION 1-1 1 (SECTION 1-1) ESCALA 1:10 (SCALE)

N° CATASTRO:

SERVICIO FITOSANITARIO DEL ESTADO CEDULA JURIDICA 3-007-521568 4-7745-75

FOLIO REAL:

4-23854-000

ESCALA

FECHA

INDICADAS

MARZO 2019

LAMINA

ACOTADO cm (DIMENSIONS IN cm)

MR-1.4