WHITE BLANCO | No. TBR20 Contacto con seguro de 20A
20A Tamper Resistant Outlet Preferido
Preferred
20A-125V
Installation instructions on inside of box Instrucciones de Instalación dentro de la caja
U.S.A ONLY / SOLO en EE.UU. Product Information Hotline Línea Automática de Información 1-800-824-3005/www.leviton.com
Manufactured and Exported By / Manufacturado y Exportado Por: Leviton Mfg. Co., Inc. 201 North Service Road, Melville, N.Y. 11747 Imported For / Importado Para: Leviton, S. de R. L. de C.V., Lago Tana No. 43 Col. Huichapan. Del. M. Hidalgo México D. F., México. CP 11290 Tel (55) 5082-1040
Leviton Preferred grade devices are built to the most demanding standards for performance and reliability. Ideal for heavily used areas in homes, offices, schools and commercial buildings. They are the preferred choice of electricians, contractors and serious DIYers.
Preferred Preferido
20A-125V
20A Tamper Resistant Outlet Contacto con seguro de 20A
5-20R
| No. TBR20
Los productos de grado Preferido de Leviton están fabricados con los estándares más exigentes para funcionamiento y confiabilidad. Ideales para áreas muy usadas en hogares, oficinas, escuelas y edificios comerciales. Son la opción preferida por los electricistas, contratistas y personas hábiles.
Made in Mexico / Hecho en México R57 R57-TBR20-W LISTED RECEPTACLE 264B
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS
PARA INSTALARSE Y/O USARSE DE ACUERDO CON LOS CODIGOS ELECTRICOS Y NORMAS APROPIADAS
ESPAÑOL PARA INSTALAR:
ADVERTENCIA: SI USTED NO ESTA SEGURO ACERCA DE ALGUNA DE LAS PARTES DE ESTAS INSTRUCCIONES, CONSULTE A UN ELECTRICISTA CALIFICADO. SOLO PARA ALIMENTACION SEPARADA: Este contactotiene una aleta rompible ubicada entre las dos terminales de latón. Si quiere que el contacto de arriba y el contacto de abajo se controlen con 2 alambres fase diferentes (dos circuitos), rompa la aleta antes de la instalación. Con un alicate de punta, doble hacia atrás y adelante hasta que se rompa. NOTA: Los tornillos terminales aceptan cable de cobre o revestido de cobre hasta #10 AWG.
ADVERTENCIA: PARA EVITAR DESCARGA ELECTRICA, FUEGO O MUERTE, INTERRUMPA EL PASO DE ENERGIA MEDIANTE EL
INTERRUPTOR DE CIRCUITO O FUSIBLE. ¡ASEGURESE QUE EL CIRCUITO NO ESTE ENERGIZADO ANTES DE INICIAR LA INSTALACION!
2. Monte el producto en la caja de pared con los tornillos provistos y monte la placa.
ADVERTENCIA: USE ESTE PRODUCTO SÓLO CON CABLE DE COBRE O REVESTIDO DE COBRE.
3. Restablezca la corriente con el fusible o interruptor de circuito.
1A. CABLEADO LATERAL: Pele aprox. 1.9 cm
4. La instalación está terminada.
A
Side Wire Cableado Lateral
B
Back Wire Cableado Posterior
Common feed (Fins intact) Alimentación Común (aletas intactas)
ENGLISH TO INSTALL:
WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN. FOR SEPARATE FEED CONVERSION ONLY: Our outlet is provided with a break-off fin located between the two brass terminal screws. If you want to have the top outlet and the bottom outlet controlled by two different hot wires (two circuits), remove the break-off fin before wiring. With needlenose pliers, bend fin back and forth until it breaks off. NOTE: Back and side wire accepts up to #10AWG copper or copper-clad wire.
Neutral/Neutro Silver screw Tornillos plateado Green screw Tornillos verde
Brass screw Tornillo latón
Ground/Tierra
Line Hot/Línea Fase
Separate feed (Remove HOT fin only) Alimentación Separada (Sólo quite la aleta FASE)
WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
(3/4") del aislante de cada conductor. Conecte los conductores según el diagrama de cableado apropiado y como sigue: Enrosque los alambres 3/4 de vuelta hacia la derecha alrededor de los tornillos terminales. Apriete firmemente los tornillos sobre el alambre enroscado.
WARNING: USE THIS DEVICE
1B. CABLEADO POSTERIOR: Pele el aislante de la punta de cada conductor de acuerdo a la medida de pelado descrita detrás del producto [aprox. 1.3 cm (1/2")]. Conecte los conductores según el diagrama como sigue. Inserte los conductores derechos debajo de las abrazaderas al lado de los tornillos terminales apropiados. Apriete firmemente los tornillos.
1A. To Side Wire: Remove insulation from each circuit conductor approx. 3/4" (1.9 cm). Connect wires per WIRING DIAGRAM as follows: Loop wires clockwise 3/4 turn around terminal screws. FIRMLY tighten screws over wire loops.
Line Hot/Línea Fase (2) Line Hot/Línea Fase (1) 1B. To Back Wire: Remove insulation from each circuit conductor per strip gauge on device [approx. 1/2" (1.3 cm)]. Connect wires per WIRING DIAGRAM as follows: Insert straight wires under clamps next to appropriate terminal screws. Tighten screws FIRMLY. 2. Mount device in wall box with screws provided and mount wallplate. 3. Restore power at circuit breaker or fuse. 4. Installation is complete.
The Class 2 USB ports are not intended for use with appliances and supporting ... The Duplex Type A & C USB Charger /Tamper Resistant Outlet provides:.
The USB ports are used to charge portable electronic devices ONLY. (NO data transfer capability). FEATURES. This device complies with Part 15 of the FCC ...
Mount device in wall box with screws provided and mount wallplate. 6. Restore power at circuit breaker ... Protected under U.S. patents pending. Neutral (White).
LIFETIME. Manufactured and Exported By / Manufacturado y. Exportado Por: Leviton Mfg. Co., Inc. 59-25. Little Neck Parkway, Little Neck, N.Y. 11362-2591.
Hubbell Incorporated (Delaware). Hubbell Incorporated (Delaware). Shelton, CT 06484. Shelton, CT 06484. 1-800-288-6000 ... The guide light connected to one receptacle opening may be turned on and off independent of the second receptacle opening by us
Green or Bare to Green Hex Screw. ⢠White or Gray to White Screw. ⢠Black or Red to Brass Screw. 3. For side wire: use #14 to #12 AWG wire, wrap conductor.
de sala de cine para películas, juegos y música. Mi Villano .... en precios de promoción ni a mayoristas ni publicados en sitio web de la competencia. Terminos y ...
mentales del PNUMA: el relacionado con el macizo de Futa. Valón. 104. .... realizarse dentro del marco central de las Naciones Unidas y no en otra parte, con la ...
$1295. GRATIS. ANTES DE QUE COMPRE CUALQUIER MUEBLE... asegúrese de visitar nuestra enorme bodega/salón de exhibición... 40,000 pies cuadrados repletos con marcas de primera calidad y todo a un precio que le ahorrará más dinero. ¡SUPERAREMOS CUALQUIE
Blanco. White/Blanc/Blanco. Ground/Mise à la terre/Tierra. Green screw/. Vis verte/. Tornillo verde. Silver screw/. Vis argent/. Tornillo plateado. Hot/Sous tension/.
LIMITED LIFETIME WARRANTY AND EXCLUSIONS. Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product ...
Floor drain. Siphon Break Part Number 285320, .... Floor drain system requires a Siphon Break Kit (Part Number. 285834) ..... at www.whirlpool.com/accessories.
Comprar. Bandejas portacables metálicas galvanizadas en caliente. El libro azul de la electricidad. Electrotecnia. Antes: 4 €. Precio oferta: 3 €. Antes: 31,25 €.
outlet is not available, it is the personal responsibility and obligation of the ...... q Remove the protective film on the console and any tape remaining on the ...
until locked. Warning/Warranty. This product is not a substitute for adult supervision. Never leave child unattended. If not completely satisfied with this product,.
This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will .... Failure to follow these instructions can result in death, fire, or electrical .... Install tubing only in areas where temperatures will re
Before you move your refrigerator into its final location, it is important to make sure ... IMPORTANT: The pressure of the water supply coming out of a reverse osmosis ...... **Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.